This circuit provides power to operate the blind spot monitor sensors.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Power Supply Voltage | Power supply voltage / Min.: 0 V, Max.: 50 V | 11 to 14 V | - |
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Power Supply Voltage | Power supply voltage / Min.: 0 V, Max.: 50 V | 11 to 14 V | - |
| Result | Proceed to |
|---|---|
| The power supply voltages of the master and slave side sensors of the blind spot monitor system are both normal. | A |
| The power supply voltage of the master side sensor of the blind spot monitor system is abnormal. | B |
| The power supply voltage of the slave side sensor of the blind spot monitor system is abnormal. | C |
A
B
C
Disconnect the P25 blind spot monitor sensor RH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| P25-5 (BRB) - Body ground | Ignition switch ON | 11 to 14 V |
| P25-5 (BRB) - Body ground | Ignition switch off | Below 1 V |
OK
NG
Disconnect the P25 blind spot monitor sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| P25-1 (BRGD) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the O46 blind spot monitor sensor LH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| O46-5 (BLB) - Body ground | Ignition switch ON | 11 to 14 V |
| O46-5 (BLB) - Body ground | Ignition switch off | Below 1 V |
OK
NG
Disconnect the O46 blind spot monitor sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O46-1 (BLGD) - Body ground | Always | Below 1 Ω |
OK
NG