DTC P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) |
DTC P0032 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1) |
DTC P0051 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1) |
DTC P0052 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1) |
DTC P101D A/F Sensor Heater Circuit Performance Bank 1 Sensor 1 Stuck ON |
DTC P103D A/F Sensor Heater Circuit Performance Bank 2 Sensor 1 Stuck ON |



| DTC No. | DTC Detection Condition | Trouble Area |
| P0031 P0051 | Air fuel ratio sensor heater current less than 0.8 A (1 trip detection logic) |
|
| P0032 P0052 | Air fuel ratio sensor heater current fail (1 trip detection logic) |
|
| P101D P103D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic) | ECM |
| Related DTCs | P0031: Air fuel ratio sensor (bank 1 sensor 1) heater open/short (Low electrical current) P0032: Air fuel ratio sensor (bank 1 sensor 1) heater open/short (High electrical current) P0051: Air fuel ratio sensor (bank 2 sensor 1) heater open/short (Low electrical current) P0052: Air fuel ratio sensor (bank 2 sensor 1) heater open/short (High electrical current) P101D: Air fuel ratio sensor (bank 1 sensor 1) heater performance P103D: Air fuel ratio sensor (bank 2 sensor 1) heater performance |
| Required Sensors/Components (Main) | Air fuel ratio sensor (bank 1,2 sensor 1) heater |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second: P101D and P103D 10 seconds: P0031 and P0051 10.24 seconds: P0032 and P0052 |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Time after heater on | 5 seconds or more |
| Active heater off control | Not operating |
| Active heater on control | Not operating |
| Air fuel ratio sensor heater performance fail (P101D, P103D) | Not detected |
| Heater output duty cycle | 30% or higher |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Time after heater on | 5 seconds or more |
| Heater output duty cycle | Higher than 0% |
| Active heater off control | Not operating |
| Active heater on control | Not operating |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Time after heater on | 5 seconds or more |
| Air fuel ratio sensor heater low current fail (P0031, P0051) | Not detected |
| Heater output duty cycle | 10% or higher, and less than 60% |
| Heater on current | 0.8 A or higher |
| Active heater off control | Not operating |
| Active heater on control | Not operating |
| Air fuel ratio sensor heater ON current | Less than 0.8 A |
| Both of the following conditions are met | - |
| Air fuel ratio sensor heater output | ON |
| Hybrid IC high current limiter monitor input | Fail |
| Both of the following conditions are met | - |
| Air fuel ratio sensor heater OFF current | Higher than 11 A |
| Hybrid IC high current limiter monitor input | Fail |
| Air fuel ratio sensor heater current | 0.8 A or more |
| Both of the following conditions are met | - |
| Air fuel ratio sensor heater output | ON |
| Hybrid IC high current limiter monitor input | Pass |
| Air fuel ratio sensor heater ON current | 11 A or less |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE) |
Inspect the air fuel ratio sensor (Click here).
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF AIR FUEL RATIO SENSOR) |
![]() |
Disconnect the air fuel ratio sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A4-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| A5-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Air Fuel Ratio Sensor) |
| *b | Bank 1 |
| *c | Bank 2 |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR FUEL RATIO SENSOR - ECM) |
Disconnect the air fuel ratio sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-1 (HA1A) - E12-17 (HA1A) | Always | Below 1 Ω |
| A5-1 (HA2A) - E12-19 (HA2A) | Always | Below 1 Ω |
| A4-1 (HA1A) or E12-17 (HA1A) - Body ground | Always | 10 kΩ or higher |
| A5-1 (HA2A) or E12-19 (HA2A) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0031, P0032, P0051, P0052, P101D OR 103D) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the Techstream on.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P0031, P0032, P0051, P0052, P101D or P103D is output | B |
|
| ||||
| A | ||
| ||
| 5.INSPECT A/F HEATER RELAY |
![]() |
Remove the A/F HEATER relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (AIR FUEL RATIO SENSOR - A/F HEATER RELAY) |
Disconnect the air fuel ratio sensor connector.
Remove the A/F HEATER relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-2 (+B) - 3 (A/F HEATER relay holder) | Always | Below 1 Ω |
| A5-2 (+B) - 3 (A/F HEATER relay holder) | Always | Below 1 Ω |
| A4-2 (+B) or 3 (A/F HEATER relay holder)- Body ground | Always | 10 kΩ or higher |
| A5-2 (+B) or 3 (A/F HEATER relay holder) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||