DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0102 | The mass air flow meter voltage is less than 0.2 V for 3 seconds. (1 trip detection logic: Engine speed is less than 4000 rpm) (2 trip detection logic: Engine speed is 4000 rpm or more) |
|
| P0103 | The mass air flow meter voltage is more than 4.9 V for 3 seconds. (1 trip detection logic: Engine speed is less than 4000 rpm) (2 trip detection logic: Engine speed is 4000 rpm or more) |
|
| Mass Air Flow Rate (gm/sec) | Malfunction |
| Approximately 0.0 |
|
| 160.0 or more | Open in E2G circuit |
| Related DTCs | P0102: Mass Air Flow Meter Range Check (Low Voltage) P0103: Mass Air Flow Meter Range Check (High Voltage) |
| Required Sensors/Components (Main) | Mass air flow meter |
| Required Sensors/Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate: Engine speed less than 4000 rpm 2 driving cycles: Engine speed 4000 rpm or more |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Mass air flow meter voltage | Less than 0.2 V |
| Mass air flow meter voltage | More than 4.9 V |
| Mass air flow meter voltage | Between 0.2 V and 4.9 V |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.READ DTC OUTPUT |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Trouble Codes.
Read DTCs.
| Result | Proceed to |
| DTC P0102 is output | A |
| DTC P0103 is output | B |
|
| ||||
| A | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF MASS AIR FLOW METER) |
![]() |
Disconnect the mass air flow meter connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| M1-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M1-3 (VG) - E5-28 (VG) | Always | Below 1 Ω |
| M1-2 (E2G) - E5-30 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| M1-3 (VG) or E5-28 (VG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.INSPECT MASS AIR FLOW METER |
Inspect the mass air flow meter, referring to the On-vehicle Inspection for mass air flow meter (Click here).
Inspect the mass air flow meter, referring to the Inspection for mass air flow meter (Click here).
Inspect the function of the mass air flow meter.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Start the engine.
Check that the MAF value changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - EFI RELAY) |
Disconnect the mass air flow meter connector.
Remove the EFI relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M1-1 (+B) - 3 (EFI relay) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| M1-1 (+B) or 3 (EFI relay) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M1-3 (VG) - E5-28 (VG) | Always | Below 1 Ω |
| M1-2 (E2G) - E5-30 (E2G) |
| Tester Connection | Condition | Specified Condition |
| M1-3 (VG) or E5-28 (VG)) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
Disconnect the mass air flow meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M1-2 (E2G) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||