DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0712 | No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic). |
|
| P0713 | No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more, or either of the following conditions is met (1-trip detection logic): |
|
| (A) 9 minutes and 40 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less. | ||
| (B) 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F). |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0712 | No. 1 ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1-trip detection logic) |
|
| P0713 | No. 1 ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more when 15 minutes or more have passed after the engine is started (1-trip detection logic) |
|
| Related DTCs | P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| The typical enabling condition is not available. | - |
| One of the following conditions is met: Condition (A) or (B) |
| The monitor will run whenever the following DTCs are not present | P0115, P0117, P0118 (ECT sensor circuit) P0110, P0112, P0113 (IAT sensor circuit) |
| Engine coolant temperature or intake air temperature at engine start | -29.375°C (-20.875°F) or less |
| Time after engine start | 9 minutes and 40 seconds or more |
| ECT sensor circuit fail (P0115, P0117, P0118) | Not detected |
| IAT sensor circuit fail (P0110, P0112, P0113) | Not detected |
| The monitor will run whenever the following DTCs are not present | P0115, P0117, P0118 (ECT sensor circuit) P0110, P0112, P0113 (IAT sensor circuit) |
| Engine coolant temperature and intake air temperature at engine start | More than -29.375°C (-20.875°F) |
| Time after engine start | 10 seconds or more |
| ECT sensor circuit fail (P0115, P0117, P0118) | Not detected |
| IAT sensor circuit fail (P0110, P0112, P0113) | Not detected |
| ATF temperature sensor resistance (No. 1 ATF temperature sensor output temperature) | Less than 79 Ω (Higher than 164°C (327.2°F)) |
| ATF temperature sensor resistance (No. 1 ATF temperature sensor output temperature) | More than 156 kΩ (Less than -48°C (-54.4°F)) |
| ATF temperature sensor resistance (No. 1 ATF temperature sensor output temperature) | 79 to 156 kΩ (-48 to 164°C (-54.4 to 327.2°F)) |

| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If value is -40°C (-40°F) or 215°C (419°F), No. 1 ATF temperature sensor circuit is open or short circuited |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (OT-) - 10 (OT+) | Always | 79 Ω to 156 kΩ |
| 2 (OT-) - Body ground | Always | 10 kΩ or higher |
| 10 (OT+) - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the connectors from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-5 (THO1) - E10-8 (ETHW) | Always | 79 Ω to 156 kΩ |
| E11-5 (THO1) - Body ground | Always | 10 kΩ or higher |
| E10-8 (ETHW) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||