Home › ENGINE · 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > MIL Circuit

for Preparation Click here


DESCRIPTION

The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunction detections by the ECM. When the ignition switch is turned ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually: When the ignition switch is first turned ON, the MIL should be illuminated and should then turn off when the engine is started. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the Techstream.

WIRING DIAGRAM


A161385E01


INSPECTION PROCEDURE

1.CHECK THAT MIL IS ILLUMINATED
  1. Perform troubleshooting in accordance with the table below.
    Result 
    Condition
    Proceed to
    MIL remains ON
    A
    MIL does not illuminate
    B



B
Go to step 5
A


2.CHECK WHETHER MIL TURNS OFF
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch ON and turn the Techstream ON.

  1. Check if DTCs have been stored (Click here). If DTCs are present, write them down.

  1. Clear DTCs (Click here).

  1. Check that the MIL turns OFF.

    Standard:
    MIL turns OFF.



NG
Go to step 3
OK

REPAIR CIRCUITS INDICATED BY OUTPUT DTCS 

3.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)
A115671E96
  1. Disconnect the A24 ECM connector.

  1. Turn the ignition switch ON.

  1. Check that the MIL is not illuminated.

    OK:
    MIL is not illuminated.

  1. Reconnect the ECM connector.



NG
Go to step 4
OK

REPLACE ECM (Click here)  

4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)
A127855E18
  1. Disconnect the A24 ECM connector.

  1. Disconnect the J28 combination meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Condition
    Specified Condition
    J28-5 (CHK) - A24-24 (W)
    Always
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    J28-5 (CHK) or A24-24 (W) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the combination meter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

5.CHECK THAT MIL IS ILLUMINATED
  1. Check if the MIL is illuminated when the ignition switch is turned ON.

    OK:
    MIL should be illuminated.



NG
Go to step 6
OK

SYSTEM OK 

6.CHECK THAT ENGINE STARTS
  1. Turn the ignition switch ON.

  1. Start the engine.
    Result 
    Result
    Proceed to
    Engine starts
    A
    Engine does not start*
    B

    HINT:
    *: The Techstream cannot communicate with the ECM.



B
GO TO VC OUTPUT CIRCUIT (Click here)
A


7.INSPECT COMBINATION METER ASSEMBLY (MIL CIRCUIT)
  1. See the combination meter troubleshooting procedure (Click here).



NG
REPLACE COMBINATION METER ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER - ECM)