The cranking holding control system keeps energizing the starter relay from when the ECM detects the starter signal (STSW signal) from the ignition switch until the ECM performs a judgment of "Engine started". Furthermore, the ECM outputs an accessory cut signal (ACCR signal) to the ACC cut relay during cranking to prevent flickering of the combination meter, clock, audio system, and so on.
When the ECM detects the STSW signal, the ECM outputs the starter relay drive signal (STAR signal) to the starter relay through the park/neutral position switch, and then, the engine is cranked. When the ECM receives a stable engine speed signal (NE signal), more specifically, when the NE signal reaches a predetermined value, the ECM stops outputting the STAR signal.
Also, the ECM monitors the starter relay operating conditions based on the STA terminal voltage status.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the result when the ignition switch is turned to the ON and START positions.
| Ignition Switch Condition | Starter Signal |
|---|---|
| ON | OFF |
| START | ON |
OK
NG
Disconnect the ECM connector.
Perform the cranking operation.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Ignition Switch Condition | Specified Condition |
|---|---|---|
| A24-14 (STSW) - Body ground | ON | Below 1 V |
| START | 9 to 13 V |
DTCs related to the communication with other computers may be set due to this inspection. Clear those DTCs after the inspection.
OK
NG
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the All Cylinders Fuel Cut.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D73-6 (Junction Connector) - Body ground | Ignition switch ON (shift lever in P or N) | Below 1 V |
| Ignition switch ON (shift lever not in P or N) | 9 to 13 V | |
| Cranking operation | 9 to 13 V |
The junction connector is in the engine room connector holder block as shown in the illustration.
During this inspection, all connectors and relays should be connected.
OK
NG
Inspect Park/Neutral Position (PNP) switch assembly.
OK
NG
Disconnect the park/neutral position (PNP) switch assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D35-4 (B) - D74-16 (STAR) | Always | Below 1 Ω |
| D35-4 (B) - D74-120 (NSW) | Always | Below 1 Ω |
OK
NG
Remove the ST relay from the engine room relay block.
Disconnect the park/neutral position (PNP) switch assembly switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D35-5 (L) - A24-46 (STA) | Always | Below 1 Ω |
| D35-5 (L) - ST relay (1) | Always | Below 1 Ω |
| ST relay (2) - Body ground | Always | Below 1 Ω |
OK
NG
Inspect the ignition switch assembly (See page Engine / Hybrid System>1UR-FE STARTING>IGNITION SWITCH>INSPECTION).
OK
NG
Inspect Park/Neutral Position (PNP) switch assembly.
OK
NG
Disconnect the ignition switch assembly connector.
Disconnect the Park/Neutral Position (PNP) switch assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J9-7 (ST2) - D35-4 (B) | Always | Below 1 Ω |
| D74-16 (STAR) - D35-4 (B) | Always | |
| D74-120 (NSW) - D35-4 (B) | Always | |
| J9-7 (ST2) or D35-4 (B) - Body ground | Always | 10 kΩ or higher |
| D74-16 (STAR) or D35-4 (B) - Body ground | Always | |
| D74-120 (NSW) or D35-4 (B) - Body ground | Always |
The wire between the PNP switch and ignition switch has a diode (refer to the wiring diagram). The current flowing to the PNP switch is rectified by the diode.
OK
NG
Remove the ST relay from the engine room relay block.
Disconnect the Park/Neutral Position (PNP) switch assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D35-5 (L) or A24-46 (STA) - Body ground | Always | 10 kΩ or higher |
| D35-5 (L) or ST relay (1) - Body ground | Always | 10 kΩ or higher |
OK
NG