A760F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

Refer to DTC P0711 (See page Drivetrain>A760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>P0711).

DTC Code DTC Detection Condition Trouble Area
P0712 ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more (1-trip detection logic).
·

Short in ATF temperature sensor circuit

·

ATF temperature sensor

·

ECM


P0713 ATF temperature sensor resistance is higher than 156 kΩ for 0.5 sec. or more and either of the following conditions is met (1-trip detection logic):
(A) 338 sec. or more have elapsed after the engine start when the engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 sec. or more have elapsed after the engine start when the engine coolant temperature and intake air temperature are higher than -29.375°C (-20.875°F).
·

Open in ATF temperature sensor circuit

·

ATF temperature sensor

·

ECM



MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects an open or short in the ATF temperature sensor circuit. If the resistance value of the ATF temperature sensor is below 79 Ω*1 or higher than 156 kΩ*2, the ECM interprets this as a fault in the ATF temperature sensor or wiring. The ECM will illuminate the MIL and store the DTC.

HINT:
·

*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

·

The ATF temperature can be checked on the Techstream display.



MONITOR STRATEGY

Related DTCs P0712: ATF temperature sensor/Range check (Low voltage)
P0713: ATF temperature sensor/Range check (High voltage)
Required sensors/Components ATF temperature sensor
Frequency of operation Continuous
Duration 0.5 seconds
MIL operation Immediately
Sequence of operation None

TYPICAL ENABLING CONDITIONS

P0712: Range check (Low voltage)
The monitor will run whenever the following DTCs are not present None
Battery voltage 8 V or higher
Ignition switch ON
Starter OFF


P0713: Range check (High voltage)

Either condition is met: Condition (A) or (B)

Condition (A)
The monitor will run whenever the following DTCs are not present P0115, P0117, P0118 (ECT (Engine Coolant Temperature) sensor circuit)
P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake Air Temperature) sensor circuit)
Engine coolant temperature or intake air temperature at engine start -29.375°C (-20.875°F) or less
Time after engine start 338 seconds or more
Battery voltage 8 V or higher
Ignition switch ON
Starter OFF


Condition (B)
The monitor will run whenever the following DTCs are not present P0115, P0117, P0118 (ECT (Engine Coolant Temperature) sensor circuit)
P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake Air Temperature) sensor circuit)
Engine coolant temperature and intake air temperature at engine start Higher than -29.375°C (-20.875°F)
Time after engine start 10 seconds or more
Battery voltage 8 V or higher
Ignition switch ON
Starter OFF



TYPICAL MALFUNCTION THRESHOLDS

P0712: Range check (Low voltage)
ATF temperature sensor voltage Below 0.14 V (Higher than 164°C (327.2°F))

P0713: Range check (High voltage)
ATF temperature sensor voltage Higher than 4.91 V (Below -48°C (-54.4°F))

COMPONENT OPERATING RANGE

ATF temperature sensor voltage 0.14 to 4.91 V

WIRING DIAGRAM

C155188E19
5.509,1.162 5.980,1.364 0.471,0.202 10 THO1 5.112,1.286 5.410,1.487 0.297,0.202 10 122 5.193,2.441 5.491,2.643 0.297,0.202 10 99 3.51,1.286 3.808,1.487 0.297,0.202 10 13 3.51,2.441 3.808,2.643 0.297,0.202 10 14 1.066,1.286 1.233,1.487 0.168,0.202 10 2 5.193,3.797 5.491,3.999 0.297,0.202 10 98 5.509,2.317 5.980,2.519 0.471,0.202 10 THO2 3.05,2.177 3.482,2.379 0.432,0.202 10 OT2+ 1.299,1.022 1.610,1.224 0.311,0.202 10 OT- 1.296,2.177 1.767,2.379 0.471,0.202 10 OT2- 5.509,3.672 5.980,3.874 0.471,0.202 10 E2 5.77,4.226 6.241,4.428 0.471,0.202 10 D74 5.77,4.412 6.241,4.614 0.471,0.202 10 ECM 1.604,3.141 2.075,3.343 0.471,0.202 10 D83 1.604,3.327 3.346,3.529 1.742,0.202 10 Transmission Wire 1.394,1.515 3.412,1.717 2.017,0.202 10 No. 1 ATF Temperature Sensor 1.394,2.668 3.412,2.870 2.017,0.202 10 No. 2 ATF Temperature Sensor 1.066,2.441 1.233,2.643 0.168,0.202 10 3 3.129,1.022 3.457,1.224 0.328,0.202 10 OT+

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>A760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


DATA LIST


HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the Techstream to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the Techstream on.


f.

Enter the following menus: Powertrain / Engine and ECT / Data List.


g.

According to the display on the Techstream, read the Data List.

Engine and ECT
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·

After stall test: Approximately 80°C (176°F)

·

Equal to ambient temperature when engine cold


If the value is -40°C (-40°F) or 150°C (302°F), the No. 1 ATF temperature sensor circuit is open or shorted.

HINT:

When DTC P0712 is output and the Techstream output is 150°C (302°F) or more, there is a short circuit.

When DTC P0713 is output and the Techstream output is -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the tester in order to check if a malfunction exists.


Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or more Short circuit

If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately stored (in 0.5 seconds). When P0713 is stored, P0711 cannot be stored.

It is not necessary to inspect the circuit when P0711 is stored.



PROCEDURE

1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)
a.
C210154E13
0.057,0.005 0.373,0.207 0.317,0.202 10 *a 1.656,1.819 2.010,2.021 0.354,0.202 10 OT+ 2.352,1.819 2.671,2.021 0.319,0.202 10 OT- 2.47,1.794 2.161,1.155 false 1.888,1.794 2.094,1.367 false

Disconnect the D83 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (OT-) - 13 (OT+) Always 79 Ω to 156 kΩ
2 (OT-) - Body ground Always 10 kΩ or higher
13 (OT+) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Standard Resistance:
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ



Text in Illustration
*a Component without harness connected
(Transmission Wire)


OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

REPAIR OR REPLACE TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U152391E02
1.094,1.802 1.5,1.271 true 1.906,1.802 1.563,1.344 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 1.604,0.302 1.979,0.531 0.375,0.229 10 false D74 0.781,1.844 1.323,2.042 0.542,0.198 10 false 98 (E2) 1.646,1.833 2.49,2.031 0.844,0.198 10 false 122 (THO1)

Disconnect the D74 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D74-122 (THO1) - D74-98 (E2) Always 79 Ω to 156 kΩ
D74-122 (THO1) - Body ground Always 10 kΩ or higher
D74-98 (E2) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR