Home › Drivetrain › A760F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27M0U _52 Drivetrain _049127 A760F AUTOMATIC TRANSMISSION / TRANSAXLE _0234175 AUTOMATIC TRANSMISSION SYSTEM C

A760F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.

C221407E01
4.729,2.135 5.031,1.188 5.031,1.188 5.094,1.188 true 4.969,2.323 5.125,2.688 5.125,2.688 5.188,2.688 true 5.76,2.396 5.917,2.688 5.917,2.688 5.979,2.688 true 6.031,2.594 6.917,2.813 0.885,0.219 10 false Solenoid Coil 0.135,0.688 1.385,0.906 1.25,0.219 10 false Hydraulic Pressure 2.573,3.01 3.135,3.229 0.563,0.219 10 false Current 5.24,2.615 5.771,2.833 0.531,0.219 10 false Sleeve 5.167,1.104 6.01,1.323 0.844,0.219 10 false Spool Valve

DTC Code DTC Detection Condition Trouble Area
P2759 Open or short is detected in the shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

ECM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store the DTC.

MONITOR STRATEGY

Related DTCs P2759: Shift solenoid valve SLU/Range check
Required sensors/Components Shift solenoid valve SLU
Frequency of operation Continuous
Duration 1 second
MIL operation Immediately
Sequence of operation None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not present None
Solenoid current cut status Not cut
Battery voltage 11 V or more
Ignition switch ON
Starter OFF

TYPICAL MALFUNCTION THRESHOLDS

Solenoid status from solenoid driver MIC Fail

COMPONENT OPERATING RANGE

Output signal duty Less than 100%

WIRING DIAGRAM

C161203E86
2.791,1.287 3.021,1.457 0.230,0.170 10 17 5.476,1.287 5.706,1.457 0.230,0.170 10 10 2.321,1.066 2.743,1.261 0.422,0.195 10 SLU+ 2.791,2.502 3.021,2.672 0.230,0.170 10 6 2.321,2.283 2.743,2.479 0.422,0.195 10 SLU- 5.782,1.181 6.204,1.377 0.422,0.195 10 SLU+ 5.476,2.502 5.706,2.672 0.230,0.170 10 11 5.782,2.401 6.204,2.596 0.422,0.195 10 SLU- 0.973,2.891 1.395,3.086 0.422,0.195 10 D83 0.973,3.069 2.812,3.265 1.839,0.195 10 Transmission Wire 1.037,1.76 2.688,1.989 1.651,0.229 10 Shift Solenoid Valve SLU 5.96,3.223 6.301,3.393 0.341,0.170 10 D74 5.96,3.376 6.383,3.571 0.422,0.195 10 ECM 0.814,1.371 1.043,1.541 0.230,0.170 10 2 0.814,2.157 1.043,2.327 0.230,0.170 10 1

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>A760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C210154E22
0.057,0.005 0.373,0.206 0.317,0.202 10 *a 1.928,1.819 2.326,2.021 0.398,0.202 10 SLU- 2.051,1.794 1.742,1.155 false 1.238,1.819 1.638,2.021 0.400,0.202 10 SLU+ 1.485,1.794 1.691,1.367 false

Disconnect the D83 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
17 (SLU+) - 6 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
17 (SLU+) - Body ground Always 10 kΩ or higher
6 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLU
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U152403E02
1.813,1.802 1.438,0.854 true 0.979,1.802 1.354,0.854 true 0.052,0 0.365,0.198 0.313,0.198 10 false *a 1.604,0.292 1.979,0.521 0.375,0.229 10 false D74 0.563,1.844 1.219,2.042 0.656,0.198 10 false 10 (SLU+) 1.51,1.854 2.219,2.052 0.708,0.198 10 false 11 (SLU-)

Disconnect the D74 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D74-10 (SLU+) - D74-11 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
D74-10 (SLU+) - Body ground Always 10 kΩ or higher
D74-11 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR