Home › Engine / Hybrid System › 1UR-FE CHARGING › GENERATOR
RM27M0U _51 Engine / Hybrid System _049146 1UR-FE CHARGING _0234376 GENERATOR A

1UR-FE CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 28800J 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 16361A 3.REMOVE FAN AND GENERATOR V BELT

a.

Remove the fan and generator V belt (See page Engine / Hybrid System>1UR-FE ENGINE MECHANICAL>DRIVE BELT>REMOVAL).


Hide 53736 5.REMOVE FRONT FENDER APRON SEAL RH

Hide 6.DISCONNECT POWER STEERING OIL PRESSURE SWITCH CONNECTOR

Hide 44320 7.DISCONNECT VANE PUMP ASSEMBLY

Hide 27020 8.REMOVE GENERATOR ASSEMBLY

a.
A215539

Remove the terminal cap.


b.

Disconnect the generator connector.


c.

Remove the nut and disconnect the generator wire.


d.

Remove the bolt and disconnect the wire harness bracket from the generator.


e.
A216790

Remove the 3 bolts, nut and generator.