For 2WD vehicles and 4WD vehicles in H2 mode, if the VSC OFF switch is pressed for a short amount of time (approximately 1 second), or if the vehicle is stopped and the VSC OFF switch is pressed for 3 seconds or more, the AUTO LSD function is activated and the AUTO LSD indicator light illuminates.
When replacing the VSC actuator assembly, perform zero point calibration (See page Brake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>VEHICLE STABILITY CONTROL SYSTEM>CALIBRATION).
Check if a CAN communication system DTC is output (See page Power Source / Network>CAN COMMUNICATION>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING).
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
A
B
(See pagePower Source / Network>CAN COMMUNICATION>CAN COMMUNICATION SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Select the Active Test mode and operate the AUTO LSD indicator light using the Techstream.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Auto LSD Indicator Light | AUTO LSD indicator light | ON / OFF | Observe combination meter |
Check that the AUTO LSD indicator light turns on and off in the combination meter when using the Techstream.
The AUTO LSD indicator light turns on and off in accordance with the Techstream operation.
When the AUTO LSD indicator light remains illuminated, there may be an open in the wire harness of the combination meter or abnormalities in the meter circuit.
OK
NG
(See pageVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING)
Remove the VSC OFF switch (See page Brake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>VSC OFF SWITCH>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 - 9 | Switch is pressed | Below 1 Ω |
| Switch is not pressed | 10 kΩ or higher |
OK
NG
Disconnect the A17 ECU connector.
Disconnect the J22 switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A17-4 (CSW) - J22-9 | Always | Below 1 Ω |
| A17-4 (CSW) - Body ground | Always | 10 kΩ or higher |
OK
NG