METER / GAUGE / DISPLAY  METER / GAUGE SYSTEM  Fuel Receiver Gauge Malfunction  


DESCRIPTION

The fuel sender gauge has a variable resistance mechanism. The resistance decreases when the fuel amount increases, and the resistance increases when the fuel amount decreases. The fuel receiver gauge changes based on the resistance of the fuel sender gauge.

WIRING DIAGRAM

B166182E06
4.444,3.05 4.722,3.238 0.278,0.188 10 J28 5.254,1.786 5.644,1.974 0.390,0.188 10 FUEL 4.185,0.757 4.398,0.945 0.213,0.188 10 26 4.185,1.302 4.398,1.490 0.213,0.188 10 25 2.604,1.302 2.772,1.490 0.168,0.188 10 2 3.476,1.302 3.644,1.490 0.168,0.188 10 3 4.456,0.757 4.822,0.945 0.366,0.188 10 L 4.456,1.302 4.822,1.490 0.366,0.188 10 E3 4.185,2.313 4.398,2.502 0.213,0.188 10 24 2.503,1.7 3.580,1.888 1.077,0.188 10 R6*1, R19*2 2.503,1.9 3.825,2.088 1.322,0.188 10 Fuel Sender Gauge 4.456,2.313 4.822,2.502 0.366,0.188 10 ES 4.444,3.232 5.723,3.420 1.279,0.188 10 Combination Meter 0.229,3.113 1.803,3.249 1.575,0.136 10 *1: except 3UR-FBE 0.229,3.389 1.803,3.526 1.575,0.136 10 *2: for 3UR-FBE

PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>B1500).

Result
Result Proceed to
DTC B1500 is not output A
DTC B1500 is output B



A

2.PERFORM ACTIVE TEST USING TECHSTREAM (FUEL RECEIVER GAUGE)

B

2.PERFORM ACTIVE TEST USING TECHSTREAM (FUEL RECEIVER GAUGE)
a.

Operate the Techstream according to the steps on the display and select "Active Test" (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST).

OK:

Needle indication is normal.


Combination Meter:
Tester Display Test Part Control Range Diagnostic Note
Fuel Meter Operation Fuel receiver gauge OFF, Sender E, Empty, Warning, 1/4, 1/2, 3/4, Full or Sender F -



OK

PROCEED TO NEXT INSPECTION PROCEDURE SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPLACE COMBINATION METER ASSEMBLY