MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU detects that a safety device (interlock) is operated or that there is an open circuit in the detection circuit. (Even if an open circuit occurs while the vehicle is stopped, the system determines that the safety device was operated.)
The cause of this malfunction may be one of the following:
Service plug malfunction
Rear hybrid motor control inverter assembly malfunction (for AWD)
Hybrid vehicle control ECU malfunction
Rear hybrid motor control inverter assembly malfunction (for AWD)
Service plug malfunction
Wire harness malfunction
Connector malfunction
INSPECTION DESCRIPTION
| System Diagram Location | Inspection Content | Reason |
|---|---|---|
| *a | ·
Check whether the safety device (interlock) is connected securely and installed properly (service plug grip, inverter terminal cover*, etc.) and HV battery pack wire*, etc. ·
Check the connection condition of the hybrid vehicle control ECU and rear hybrid motor control inverter assembly* connector. |
DTC output due to improper connection or forgetting to install parts. |
| *b | Inspect the detection circuit. | DTC output due to an open circuit or improper connection (dirt, foreign matter, etc.). |
*: for AWD
When the hybrid vehicle control ECU detects that a safety device (interlock) is operated (such as removal of the service plug grip, inverter cover, inverter terminal cover (for AWD) or HV battery pack wire (for AWD)), it will prohibit hybrid system operation or shut off the system main relays. The safety devices are located as follows: 1 in the service plug grip, 1 on the inverter cover for the terminals of the hybrid motor control inverter assembly motor cable, 1 on the inverter terminal cover for the terminals of the rear motor cable, hybrid underfloor wire and HV battery pack wire of the rear hybrid motor control inverter assembly (for AWD), and 1 on the HV battery pack wire that connects to the rear hybrid motor control inverter assembly (for AWD). If the service plug grip, inverter cover, inverter terminal cover (for AWD) or HV battery pack wire is removed, the interlock signal line will be open. However, if the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. When the safety devices are re-installed correctly, the system will return to normal when the ignition switch is turned to ON.
The system main relay will be turned off from the next trip after the open is detected until the condition returns to normal.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A0A13 | High Voltage System Interlock Circuit Open | Interlock signal line opens while the vehicle is being driven (at 5 km/h (3 mph) or more)
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Service plug grip ·
Rear hybrid motor control inverter assembly* ·
HV battery pack wire* ·
Inverter terminal cover* |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation | Either of the following conditions is met:
·
With the vehicle stopped, the service plug grip with a safety device was removed. ·
With the vehicle stopped, the interlock signal line became open. (1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Service plug grip ·
Rear hybrid motor control inverter assembly* ·
HV battery pack wire* ·
Inverter terminal cover* |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
*: for AWD
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
As interlock circuit DTCs or other DTCs may be stored when the ignition switch to ON in the following procedure, make sure to clear the DTCs after inspection.
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A0A13 or P0A0A92 is output and DTCs other than the DTCs in the table below are output | A |
| P0A0A13 or P0A0A92 is output and any DTCs in the table below are output | B |
| Only P0A0A13 or P0A0A92 is output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck | |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range | |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure | |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck | |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range | |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure | |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure | |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid | |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure | |
| Power source circuit malfunction | P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| System malfunction | P1C9E9F | Hybrid/EV System Reset Stuck Off |
P0A0A13 or P0A0A92 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A0A13 or P0A0A92 is output | A |
| P0A0A13 and P0A0A92 are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Be sure to wear insulated gloves.
| *1 | Service Plug Grip |
Check if the service plug grip is installed correctly.
Insert the service plug grip until a click sound is heard.
For the removal and installation procedures.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>REMOVAL
P0A0A92 is also set if the ignition switch is turned to ON with the service plug grip removed. Confirm the conditions when the malfunction occurred.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
| *1 | Interlock Connector |
Check that the interlock connector at the service plug grip installation socket is connected correctly.
The connector is connected correctly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the HV battery upper cover panel.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O72 service plug grip (interlock switch) connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Rear view of wire harness connector
(to Service Plug Grip (Interlock Switch)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O72)Location & Routingewd_type=routing;type=c;code=O72 Click Connector(O72)Body>Floor Wire>Inter Lock Switchewd_type=component;type=c;code=O72;pinno=1 |
||
| O72-1 (ILK) - Body ground | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the O72 service plug grip (interlock switch) connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Remove the service plug grip.
Procedure1
| *1 | Service Plug Grip |
Check the condition of the service plug grip interlock.
Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O72 service plug grip (interlock switch) connector.
Procedure1
| *a | Rear view of wire harness connector
(to Service Plug Grip (Interlock Switch)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O72)Location & Routingewd_type=routing;type=c;code=O72 Click Connector(O72)Body>Floor Wire>Inter Lock Switchewd_type=component;type=c;code=O72;pinno=2 |
||
| O72-2 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O72 service plug grip (interlock switch) connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the H44 hybrid vehicle control ECU connector.
Remove the HV battery upper cover panel.
Disconnect the O72 service plug grip (interlock switch) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
*b | Rear view of wire harness connector
(to Service Plug Grip (Interlock Switch)) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H44,O72)Location & Routingewd_type=routing;type=c,c;code=H44,O72 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=32 Click Connector(O72)Body>Floor Wire>Inter Lock Switchewd_type=component;type=c;code=O72;pinno=1 |
||
| H44-32 (ILK) - O72-1 (ILK) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O72 service plug grip (interlock switch) connector.
Install the HV battery upper cover panel.
Reconnect the H44 hybrid vehicle control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O72 service plug grip (interlock switch) connector.
Procedure1
| *a | Rear view of wire harness connector
(to Service Plug Grip (Interlock Switch)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O72)Location & Routingewd_type=routing;type=c;code=O72 Click Connector(O72)Body>Floor Wire>Inter Lock Switchewd_type=component;type=c;code=O72;pinno=2 |
||
| O72-2 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O72 service plug grip (interlock switch) connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the O74 rear hybrid motor control inverter assembly connector.
Procedure1
| *a | Front View of Wire Harness Connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O74)Location & Routingewd_type=routing;type=c;code=O74 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=1,7 |
||
| O74-1 (GNR1) - Body ground | Ignition switch off | Below 1 Ω |
| O74-7 (GNR2) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O74 rear hybrid motor control inverter assembly connector.
OK
NG
Check the connections of each connector.
Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
| *1 | Interlock Connector |
Check that the interlock connector at the service plug grip installation socket is connected correctly.
The connector is connected correctly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check if the inverter terminal cover from the rear hybrid motor control inverter assembly is installed correctly.
The inverter terminal cover is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Procedure1
Check if the HV battery pack wire is installed correctly.
The HV battery pack wire is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Procedure1
| *1 | Inverter Terminal Cover |
Check the condition of the inverter terminal cover interlock.
Dirt or foreign matter has not entered the connectors and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Procedure1
| *1 | Rear Hybrid Motor Control Inverter Assembly |
Check the condition of the HV battery pack wire interlock.
Dirt or foreign matter has not entered the connectors and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Install the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the O72 service plug grip (interlock switch) connector.
Disconnect the O74 rear hybrid motor control inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Service Plug Grip (Interlock Switch)) |
*b | Front View of Wire Harness Connector
(to Rear Hybrid Motor Control Inverter Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O72,O74)Location & Routingewd_type=routing;type=c,c;code=O72,O74 Click Connector(O72)Body>Floor Wire>Inter Lock Switchewd_type=component;type=c;code=O72;pinno=2 Click Connector(O74)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O74;pinno=3 |
||
| O72-2 (GND) - O74-3 (ILKI) | Power switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O74 rear hybrid motor control inverter assembly connector.
Reconnect the O72 service plug grip (interlock switch) connector.
OK
NG