MALFUNCTION DESCRIPTION
This DTC indicates an abnormality in the rear air cooling system. The cause of this malfunction may be one of the following:
Rear inverter internal circuit malfunction
Malfunction in ECU controlling rear inverter
Rear inverter control sensor malfunction (base temperature sensor)
Air cooling fan malfunction
Air cooling fin clogging
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0C3100 | Drive Motor Inverter Temperature Sensor "C" Circuit | The base temperature increases, and at the same time the rear inverter temperature also increases.
(3 trip detection logic) |
·
Wire harness or connector ·
HV inverter cooling fan ·
Rear hybrid motor control inverter assembly |
Does not come on | Master Warning:
Comes on |
Rear Motor Generator | A |
| DTC No. | Data List |
|---|---|
|
*1: Temperature of inverter base plate (frame body) upon which elements are mounted |
|
| P0C3100 | ·
Rear Motor Base Temperature*1 ·
Rear Motor Inverter Temperature |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
Drive the vehicle for approximately 10 minutes mainly using the engine.
Check that the deviation of the "Rear Motor Base Temperature" and "Rear Motor Inverter Temperature" on the Data List is within 60°C (34°F).
Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
Refer to the wiring diagram for the Rear Cooling System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Cooling System
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0C3100 for Rear motor generator control system is output | A |
| P0C3100 and DTCs other than the DTCs in the table below are output | B |
| P0C3100 and Insulation malfunction of Hybrid control system DTCs in the table below are output | C |
| P0C3100 and High voltage circuit malfunction of Hybrid control system DTCs in the table below are output | D |
| P0C3100 and Microcomputer malfunction of Rear motor generator control system DTCs in the table below are output | E |
| P0C3100 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | F |
| P0C3100 and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output | G |
| P0C3100 and Communication malfunction of Rear motor generator control system DTCs in the table below are output | H |
| P0C3100 and Communication malfunction of Motor generator control system DTCs in the table below are output | I |
| P0C3100 and Sensor and actuator circuit malfunction of Rear motor generator control system DTCs in the table below are output | J |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| High voltage circuit malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Rear motor generator control system | P0A1C1F | Drive Motor B" Control Module Circuit Intermittent |
| P1C2C1C | Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range | ||
| P1C2C49 | Drive Motor B" Control Module AD Converter Circuit Internal Electronic Failure | ||
| Motor generator control system | P0A1C49 | Drive Motor B" Control Module Internal Electronic Failure" | |
| Power source circuit malfunction | Rear motor generator control system | P06B31C | Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P262C1C | Drive Motor B" Control Module Offset Power Circuit Voltage Out of Range | ||
| Communication malfunction | Rear motor generator control system | P314987 | Lost Communication between Drive Motor A" and "B" Missing Message |
| Motor generator control system | P314887 | Lost Communication between Drive Motor A" and "B" Missing Message" | |
| Sensor and actuator circuit malfunction | Rear motor generator control system | P0AF211 | Drive Motor Inverter Temperature Sensor B" Circuit Short to Ground |
| P0AF215 | Drive Motor Inverter Temperature Sensor B" Circuit Short to Battery or Open | ||
| P0AF21F | Drive Motor Inverter Temperature Sensor B" Circuit Intermittent | ||
| P0BD111 | Drive Motor Inverter Temperature Sensor C" Circuit Circuit Short to Ground | ||
| P0BD115 | Drive Motor Inverter Temperature Sensor C" Circuit Circuit Short to Battery or Open | ||
| P0BD11F | Drive Motor Inverter Temperature Sensor C" Circuit Circuit Intermittent | ||
| P310462 | Drive Motor Inverter Temperature Sensor B" Signal Compare Failure | ||
P0C3100 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
E
F
G
H
I
J
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Cooling System
| Proceed to |
|---|
| NEXT |
NEXT