Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0442914 REAR MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  P0C5516  Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold  P0C5517  Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold  P0C5F16  Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold  P0C5F17  Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the resolver output signal is abnormal. The cause of this malfunction may be one of the following:


Rear inverter internal malfunction
·

Rear inverter assembly internal circuit malfunction


Rear inverter low-voltage circuit malfunction
·

The connectors are not connected properly


HINT:

If either of these DTCs is output, malfunction of the rear motor generator control ECU circuit board or poor connection of low-voltage connectors is suspected. It is not necessary to inspect the motor resolver.


DESCRIPTION

Refer to the system description for the Rear Motor Resolver Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor Resolver Circuit

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P0C5516 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold The rear motor resolver sin phase signal is out of the standard range (Amplitude is greater than maximum threshold)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0C5517 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold The rear motor resolver sin phase signal is out of the standard range (Amplitude is less than minimum threshold)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0C5F16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold The rear motor resolver cos phase signal is out of the standard range (Amplitude is greater than maximum threshold)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0C5F17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold The rear motor resolver cos phase signal is out of the standard range (Amplitude is less than minimum threshold)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

5.

Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.

6.

Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.

7.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




HINT:
·

If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.

·

If the resolver is malfunctioning, the vehicle may not drive smoothly.

·

When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.

·

As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.



PROCEDURE

1.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0C5516, P0C5517, P0C5F16 or P0C5F17 for Rear motor generator control system is output A
P0C5516, P0C5517, P0C5F16 or P0C5F17 is output and DTCs other than the DTCs in the table below are output B
P0C5516, P0C5517, P0C5F16 or P0C5F17 is output and Insulation malfunction of Hybrid control system DTCs in the table below are output C
P0C5516, P0C5517, P0C5F16 or P0C5F17 is output and Microcomputer malfunction of Motor generator control system DTCs in the table below are output D
P0C5516, P0C5517, P0C5F16 or P0C5F17 is output and Microcomputer malfunction of Rear motor generator control system DTCs in the table below are output E
P0C5516, P0C5517, P0C5F16 or P0C5F17 is output and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output F


Table 1
Malfunction Content System Relevant DTC
Insulation malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1C49 Drive Motor B" Control Module Internal Electronic Failure"
P314887 Lost Communication between Drive Motor A" and "B" Missing Message"
Rear motor generator control system P1C2C1C Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C49 Drive Motor B" Control Module AD Converter Circuit Internal Electronic Failure
P314987 Lost Communication between Drive Motor A" and "B" Missing Message
Power source circuit malfunction Rear motor generator control system P06B31C Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P262C1C Drive Motor B" Control Module Offset Power Circuit Voltage Out of Range

HINT:

P0C5516, P0C5517, P0C5F16 or P0C5F17 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

C

D

E

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

F

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR