Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER › from 2021.07
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0441188 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
A461932N05
6.385,0.208 6.76,0.208 false 6.375,0.802 6.75,0.802 false 1.552,1.271 1.927,1.271 false 6.198,0.073 7.146,0.563 0.948,0.49 18 false 1 1.344,1.125 2.292,1.615 0.948,0.49 18 false 2 6.156,0.646 6.667,1.042 0.51,0.396 18 false 3

Procedure Part Name Code
Z101186

Z101188

Z101187

1 PRECAUTION - (Click here) - -
2 SERVICE PLUG GRIP G3834 - - -
3 COOLANT (for Inverter) - - (Click here) -

A490433N01
0.052,0.125 2.177,4.083 2.125,3.958 4.833,0.917 5.833,1.083 1,0.167 0.052,2.052 2.177,2.052 false 1.156,0.49 1.51,0.49 false 1.833,1.156 1.833,1.365 false 0.698,1.406 0.698,1.615 false 0.667,3.271 0.667,3.479 false 1.729,3.104 1.729,3.26 false 1.167,2.51 1.469,2.51 false 3.552,0.865 3.854,0.865 false 4.177,1.854 4.677,1.854 false 3.813,2.302 4.219,2.302 false 2.49,3.063 2.531,3.417 2.531,3.417 2.698,3.417 false 6.573,0.26 6.875,0.26 false 6.104,1.896 6.271,1.896 false 6.271,2.292 6.479,2.292 false 0.781,5.271 1.083,5.271 false 6.125,1.5 6,1 6,1 5.833,1 false 0.073,0.177 0.448,0.417 0.375,0.24 12 false *A 0.073,2.083 0.448,2.323 0.375,0.24 12 false *B 1.542,0.313 1.917,0.604 0.375,0.292 18 false 13 0.51,1.635 0.885,1.927 0.375,0.292 18 false 16 1.646,1.365 2.021,1.656 0.375,0.292 18 false 14 1.073,0.823 1.448,1.115 0.375,0.292 10 false x12 1.49,2.333 1.865,2.625 0.375,0.292 18 false 13 1.573,3.26 1.948,3.552 0.375,0.292 18 false 15 0.479,3.51 0.854,3.802 0.375,0.292 18 false 16 0.375,2.323 0.75,2.615 0.375,0.292 10 false x11 0.604,5.104 0.979,5.396 0.375,0.292 18 false 4 3.01,3.271 3.385,3.563 0.375,0.292 18 false 5 3.604,2.125 3.979,2.417 0.375,0.292 18 false 6 3.875,1.688 4.25,1.979 0.375,0.292 18 false 11 6.583,1.74 7.083,2.052 0.5,0.313 18 false 7, 9 6.76,2.125 7.094,2.417 0.333,0.292 18 false 10 6.365,0.115 6.781,0.427 0.417,0.313 18 false 8 4.583,1.281 4.958,1.573 0.375,0.292 10 false x2 5.896,1.531 6.271,1.823 0.375,0.292 10 false x2 2.927,2.188 3.302,2.479 0.375,0.292 10 false x2 3.885,0.688 4.26,0.979 0.375,0.292 18 false 12 4.875,0.917 5.979,1.094 1.104,0.177 8 false 4.5 (46, 40 in.*lbf)

Procedure Part Name Code
Z101186

Z101188

Z101187

4 AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE - - - -
5 ECM 89661 (Click here) - -
6 ENGINE WIRE 82121 (Click here) - -
7 REMOVE CONNECTOR COVER ASSEMBLY - (Click here) - -
8 TERMINAL VOLTAGE - (Click here) - -
9 TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY - (Click here) - -
10 HV FLOOR UNDER WIRE 821H1 (Click here) - -
11 HV AIR CONDITIONING WIRE 821H2 (Click here) - -
12 WINDSHIELD WIPER MOTOR AND LINK - - - -
13 FRONT NO. 1 VENTILATOR SEAL 55815E - - -
14 WATER GUARD PLATE RH 55734A - - -
15 WATER GUARD PLATE LH 55735A - - -
16 OUTER COWL TOP PANEL SUB-ASSEMBLY 55701J - - -

*A for LHD *B for RHD
V100146

N*m (kgf*cm, ft.*lbf): Specified torque - -

A461197N04
4.583,1.083 5.031,1.083 false 1.708,2.094 2.073,2.094 false 2.344,3.094 2.708,3.094 false 2.104,4.594 2.031,4.292 2.031,4.292 1.865,4.292 false 4.625,4.344 4.792,4.198 4.792,4.198 4.938,4.198 false 5.74,3.698 6.104,3.698 false 5.354,5.271 5.417,5.552 5.417,5.552 5.552,5.552 false 2.104,5.083 2.146,5.333 2.146,5.333 2.208,5.333 false 5.469,0.958 6.021,1.313 0.552,0.354 18 false 18 6.177,3.563 6.729,3.917 0.552,0.354 18 false 16 5.313,4.083 5.865,4.438 0.552,0.354 18 false 22 5.896,5.385 6.448,5.74 0.552,0.354 18 false 21 2.49,5.25 3.042,5.604 0.552,0.354 18 false 20 1.583,4.125 2.135,4.479 0.552,0.354 18 false 19 2.771,2.979 3.323,3.333 0.552,0.354 18 false 23 2.156,1.969 2.708,2.323 0.552,0.354 18 false 17 2.625,1.26 3.177,1.615 0.552,0.354 10 false x2 1.75,2.729 2.302,3.083 0.552,0.354 10 false x2 4.646,3.531 5.198,3.885 0.552,0.354 10 false x4 2.76,4.865 3.313,5.219 0.552,0.354 10 false x2 4.698,4.948 5.25,5.302 0.552,0.354 10 false x4 5.083,4.771 5.635,5.125 0.552,0.354 10 false x6 6.083,5.146 6.635,5.5 0.552,0.354 10 false x2

Procedure Part Name Code
Z101186

Z101188

Z101187

16 WIRE HARNESS CLAMP BRACKET - - - -
17 PURGE VALVE (PURGE VSV) 25860 - - -
18 ENGINE WIRE 82121 (Click here) - -
19 OUTLET NO. 1 INVERTER COOLING HOSE G922C (Click here) - -
20 INLET NO. 1 INVERTER COOLING HOSE G922AA (Click here) - -
21 UPPER INVERTER COVER G9022A (Click here) - -
22 MOTOR CABLE G1148 (Click here) - -
23 INVERTER PROTECTOR G921E - - -

A458011N02
2.25,4.917 2.667,4.917 false 1.542,1.979 1.958,1.979 false 3.729,1.094 4.146,1.094 false 6.177,2.271 6.594,2.271 false 4.406,3.125 4.823,3.125 false 5.5,3.969 5.917,3.969 false 4.875,3 5.354,3.333 0.479,0.333 18 false 25 5.99,3.854 6.469,4.188 0.479,0.333 18 false 27 2.75,4.802 3.229,5.135 0.479,0.333 18 false 26 6.323,1.75 6.802,2.083 0.479,0.333 10 false x2 1.021,4.583 1.5,4.917 0.479,0.333 10 false x2 6.677,2.135 7.156,2.469 0.479,0.333 18 false 24 4.24,0.948 4.719,1.281 0.479,0.333 18 false 27 1.26,1.823 1.74,2.156 0.479,0.333 18 false 27

Procedure Part Name Code
Z101186

Z101188

Z101187

24 NO. 2 INVERTER BRACKET G9215 - - -
25 HYBRID MOTOR CONTROL INVERTER ASSEMBLY G9200 (Click here) - -
26 NO. 1 INVERTER BRACKET G9214 - - -
27 WIRE HARNESS CLAMP BRACKET - - - -

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during hybrid motor control inverter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (w/o Advanced Park) (Click here)
Replacement of hybrid motor control inverter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


(Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



HINT:

When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 second or more. (Click here)
Pre-collision system
Parking support brake system

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Power back door system Fully close the back door by hand.
HINT:

Initialization is not necessary if the above procedures are performed while the back door is closed.


(Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -



PROCEDURE

Hide 1. PRECAUTION

Z101186

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.

Click here(Click here)



Hide 3.DRAIN COOLANT (for Inverter)

Hide 4.REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE

a.
A472775


Hide 89661 5.REMOVE ECM

Z101186

Click here(Click here)

Hide 82121 6.DISCONNECT ENGINE WIRE

Z101186

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.



a.
A490452N01
2.427,0.135 2.604,0.458 0.177,0.323 18 true i

i.

Move the lock lever while pushing the lock on the connector, and disconnect the hybrid motor control inverter assembly connector.

NOTICE:
·

Do not damage the terminals, connector housing or hybrid motor control inverter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.





b.

for LHD:

A490454N01
2.146,0.052 2.427,0.406 0.281,0.354 18 false i

i.

Disengage the 3 clamps and disconnect the engine wire.



c.

for RHD:

A490453N01
2.135,0.021 2.417,0.375 0.281,0.354 18 false i

i.

Disengage the 2 clamps and disconnect the engine wire.



Hide 7.REMOVE CONNECTOR COVER ASSEMBLY

Z101186

CAUTION:

Wear insulated gloves.



a.
A461447C01
3.917,1.042 4.104,1.229 0.188,0.188 10 true *a 3.729,0.417 3.917,0.615 0.188,0.198 10 true *b 3.969,0.354 4.188,0.635 0.219,0.281 18 true i 4.49,0.938 4.708,1.219 0.219,0.281 18 true ii
*a Bolt (A) *b Bolt (B)


i.

Remove the bolt (B).


ii.

Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the hybrid motor control inverter assembly.

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.





Hide 8.CHECK TERMINAL VOLTAGE

Z101186

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.



a.
A461448N01
2.198,0.021 2.333,0.292 0.135,0.271 18 true i

i.

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard Voltage:

0 V


HINT:

Use a measuring range of DC 750 V or more on the voltmeter.




Hide 9.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

Z101186

CAUTION:

Wear insulated gloves.


NOTICE:

Do not touch the waterproof seal of the connector cover assembly.



a.
A461456N01
2.219,0.052 2.365,0.344 0.146,0.292 18 true i

i.

Using a T25 "TORX" socket wrench, temporarily install the connector cover assembly to the hybrid motor control inverter assembly with the bolt.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)



Hide 821H1 10.DISCONNECT FLOOR UNDER WIRE

Z101186

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.


NOTICE:
·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or hybrid motor control inverter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

Insulate the disconnected terminals with insulating tape.




a.
A461449C01
1.417,0.469 1.917,0.469 true 1.208,0.385 1.521,0.583 0.313,0.198 10 false *a 3.156,1.417 3.323,1.688 0.167,0.271 18 true ii 4.188,0.802 4.333,1.073 0.146,0.271 18 true i
*a Waterproof Seal - -


i.

Remove the bolt and disconnect the HV floor under wire from the hybrid motor control inverter assembly.


ii.

Disengage the 2 clamps.



Hide 821H2 11.DISCONNECT HV AIR CONDITIONING WIRE

Z101186

CAUTION:

Wear insulated gloves.


NOTICE:
·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or hybrid motor control inverter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.




a.
A461450C01
3.083,0.583 3.75,0.583 true 3.823,0.5 4.135,0.698 0.313,0.198 10 false *a 3.521,1.677 3.667,1.979 0.146,0.302 18 true i 3.969,2.125 4.177,2.406 0.208,0.281 18 true ii
*a Waterproof Seal - -


i.

Remove the 2 bolts and disconnect the air conditioning wire from the hybrid motor control inverter assembly.


ii.

Disengage the clamp.



Hide 12.REMOVE WINDSHIELD WIPER MOTOR AND LINK

Hide 55734A 14.REMOVE WATER GUARD PLATE RH (for LHD)

Hide 55735A 15.REMOVE WATER GUARD PLATE LH (for RHD)

Hide 17.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A457984


Hide 25860 18.REMOVE PURGE VALVE (PURGE VSV)

Hide 82121 19.DISCONNECT ENGINE WIRE

Z101186

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.



a.
A461933N02
0.469,0.073 0.646,0.385 0.177,0.313 18 true i 4,0.073 4.177,0.385 0.177,0.313 18 true ii 4.01,2.198 4.24,2.51 0.229,0.313 18 true iii 6.135,4.031 6.365,4.344 0.229,0.313 18 true iv

i.

Move the lock lever while pushing the lock on the connector, and disconnect the hybrid motor control inverter assembly connector.

NOTICE:
·

Do not damage the terminals, connector housing or hybrid motor control inverter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.




ii.

Disengage the 3 clamps and disconnect the No. 1 fuel vapor feed hose.


iii.

Disengage the 2 clamps.


iv.

Remove the bolt.



b.
A460038


c.
C430792


Hide G922C 20.DISCONNECT OUTLET NO. 1 INVERTER COOLING HOSE

Z101186

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



a.
A461451


Hide G922AA 21.DISCONNECT INLET NO. 1 INVERTER COOLING HOSE

Z101186

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



a.
A461452


Hide G9022A 22.REMOVE UPPER INVERTER COVER

Z101186

CAUTION:

Wear insulated gloves.



a.
A502557N01
1.802,0.083 2.083,0.438 0.281,0.354 18 false i

i.

Loosen the 2 bolts, leaving 2 to 3 threads at the tip of the bolt still engaged.



b.
A502565C01
4.458,1.156 4.5,0.698 4.5,0.698 4.615,0.698 false 6.156,1.438 6.292,1.438 6.292,1.438 6.354,1.052 false 5.156,1.177 5.229,1.49 5.229,1.49 5.385,1.49 true 4.917,0.979 5.26,0.719 5.26,0.719 5.083,1.094 true 4.708,0.635 4.865,0.833 0.156,0.198 10 false A 5.979,1.385 6.135,1.583 0.156,0.198 10 false A 5.448,1.427 5.729,1.667 0.281,0.24 10 false *a 5.292,0.604 5.573,0.844 0.281,0.24 10 false *b 1.76,0.052 2.24,0.438 0.479,0.385 18 false i, ii
*a Interlock *b Waterproof Seal


i.

Using the 2 bolts as guides, remove the upper inverter cover from the inverter with converter assembly.

NOTICE:
·

Make sure to pull the upper inverter cover straight out, as a connector is connected to the inside of the upper inverter cover.

·

Do not touch the waterproof seal of the upper inverter cover.

·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

When removing the upper inverter cover, do not pull the areas (A) as they may deform.

·

Make sure that the interlock is installed to the upper inverter cover.

·
A464129C01
2.146,2.104 2.656,1.635 2.656,1.635 2.031,1.469 false 1.031,0.313 1.302,0.313 1.302,0.313 1.781,0.906 true 0.854,0.208 1.167,0.406 0.313,0.198 10 false *a 2.698,1.521 3.01,1.719 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the upper inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.

·
A502558N01
2.083,0.281 3.333,0.281 false 2.104,1.688 3.354,1.688 false 2.104,3.5 3.354,3.5 false 2.115,4.073 3.365,4.073 false

Hold the upper inverter cover horizontal while removing it.



HINT:
A502566

If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the upper inverter cover.



ii.

Remove the 2 bolts.



Hide G1148 23.DISCONNECT MOTOR CABLE

Z101186

CAUTION:

Wear insulated gloves.



a.
A461454N01
2.219,0.052 2.365,0.354 0.146,0.302 18 true i

i.

Using an insulated tool, remove the 6 bolts.

NOTICE:
·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

Do not touch the waterproof seal or terminals of the connector.





b.
A461455N01
2.188,0.083 2.469,0.438 0.281,0.354 18 false i

i.

Remove the 4 bolts and disconnect the motor cable from the hybrid motor control inverter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or hybrid motor control inverter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·
A464133

To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.





Hide G921E 24.REMOVE INVERTER PROTECTOR

a.
A458002


Hide G9215 25.REMOVE NO. 2 INVERTER BRACKET

a.
A461929


Hide G9200 26.REMOVE HYBRID MOTOR CONTROL INVERTER ASSEMBLY

Z101186

CAUTION:

Be sure to wear insulated gloves.


NOTICE:
·

When removing the hybrid motor control inverter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the hybrid motor control inverter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.




a.
A461930N01
2.021,0.031 2.302,0.385 0.281,0.354 18 false i

i.

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the hybrid motor control inverter assembly so that coolant does not spill out.



Hide G9214 27.REMOVE NO. 1 INVERTER BRACKET

a.
A460046


Hide 28.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A461161