Home › Engine / Hybrid System › 1NZ-FE ENGINE CONTROL › 1NZ-FE SFI SYSTEM › 2015.06–2016.09
RM19S0E _51 Engine / Hybrid System _051448 1NZ-FE ENGINE CONTROL _0248039 1NZ-FE SFI SYSTEM J

1NZ-FE ENGINE CONTROL  1NZ-FE SFI SYSTEM  VC Output Circuit  


DESCRIPTION

The ECM constantly generates 5 V power from the battery voltages supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.

A254573E03
4.88,3.228 5.251,3.394 0.371,0.166 10 ECM 5.434,1.876 6.416,2.032 0.982,0.156 10 Microprocessor 4.481,0.979 6.283,1.149 1.802,0.170 10 5 V Constant Voltage Circuit 0.329,2.759 2.666,3.102 2.336,0.343 10 Engine Coolant Temperature Sensor, Intake Air Temperature Sensor, etc. 0.329,1.848 2.659,2.344 2.330,0.496 10 Throttle Position Sensor, Accelerator Pedal Position Sensor, etc. (Sensors which have IC) 1.277,0.869 2.641,1.039 1.364,0.170 10 from EFI MAIN Fuse 1.277,1.217 2.607,1.380 1.330,0.163 10 from EFI MAIN Relay 2.863,1.331 3.394,1.480 0.531,0.149 10 +B, +B2 2.937,0.979 3.350,1.144 0.413,0.165 10 BATT 3.227,2.261 3.437,2.412 0.210,0.150 10 VC 4.127,2.874 4.248,3.016 0.121,0.142 10 R

When the VC circuit is short-circuited, the microprocessor in the ECM and sensors that are supplied with power through the VC circuit are inactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.

HINT:

Under normal conditions, the MIL is illuminated for several seconds when the ignition switch is first turned to ON. The MIL goes off when the engine is started.


WIRING DIAGRAM

A254095E01
4.584,1.074 4.858,1.216 0.274,0.142 10 B84 0.395,2.387 2.588,2.566 2.193,0.178 10 Throttle with Motor Body Assembly 0.395,5.29 2.754,5.469 2.360,0.178 10 Accelerator Pedal Sensor Assembly 1.978,0.694 2.224,0.873 0.247,0.178 10 VC 1.788,2.926 2.211,3.105 0.423,0.178 10 VCPA 1.788,3.296 2.206,3.474 0.418,0.178 10 VCP2 1.886,3.682 2.235,3.860 0.348,0.178 10 VPA 1.816,4.034 2.225,4.212 0.409,0.178 10 VPA2 1.886,4.418 2.198,4.596 0.311,0.178 10 EPA 1.816,4.772 2.207,4.951 0.390,0.178 10 EPA2 4.92,2.858 5.535,3.036 0.615,0.178 10 VCPA 4.92,3.238 5.535,3.416 0.615,0.178 10 VCP2 4.92,3.675 5.535,3.853 0.615,0.178 10 VPA 4.92,4.048 5.535,4.226 0.615,0.178 10 VPA2 4.92,4.331 5.535,4.510 0.615,0.178 10 EPA 4.92,4.702 5.535,4.881 0.615,0.178 10 EPA2 1.9,1.061 2.210,1.239 0.309,0.178 10 VTA 1.816,1.423 2.216,1.601 0.399,0.178 10 VTA2 1.985,1.813 2.208,1.992 0.223,0.178 10 E2 4.92,0.621 5.535,0.800 0.615,0.178 10 VCTA 5.523,5.477 5.866,5.655 0.343,0.178 10 ECM 4.92,1.061 5.535,1.239 0.615,0.178 10 VTA1 4.92,1.437 5.535,1.615 0.615,0.178 10 VTA2 4.92,1.754 5.535,1.933 0.615,0.178 10 ETA 0.395,5.166 0.669,5.339 0.274,0.173 10 A36 0.395,2.256 0.681,2.410 0.286,0.154 10 B29 4.584,1.824 4.858,1.966 0.274,0.142 10 B84 4.584,3.68 4.858,3.822 0.274,0.142 10 A74 4.584,4.051 4.858,4.193 0.274,0.142 10 A74 4.584,4.421 4.858,4.563 0.274,0.142 10 A74 4.584,4.792 4.858,4.934 0.274,0.142 10 A74 4.584,2.938 4.858,3.080 0.274,0.142 10 A74 4.584,3.309 4.858,3.451 0.274,0.142 10 A74 4.583,1.45 4.859,1.596 0.276,0.145 10 B84 4.584,0.696 4.858,0.838 0.274,0.142 10 B84 4.614,1.653 4.787,1.808 0.173,0.156 10 91 4.608,3.131 4.792,3.269 0.184,0.139 10 58 4.612,3.502 4.789,3.641 0.177,0.139 10 55 4.607,4.602 4.794,4.758 0.187,0.156 10 60 4.605,4.255 4.796,4.411 0.191,0.156 10 59 4.61,3.877 4.790,4.015 0.180,0.139 10 56 4.608,2.759 4.792,2.915 0.184,0.156 10 57 4.57,1.274 4.830,1.430 0.260,0.156 10 114 4.57,0.882 4.830,1.038 0.260,0.156 10 115 4.61,0.509 4.790,0.665 0.180,0.156 10 67 2.288,1.36 2.385,1.513 0.097,0.152 10 4 2.288,1.721 2.385,1.873 0.097,0.152 10 3 2.288,2.824 2.385,2.977 0.097,0.152 10 4 2.288,3.203 2.385,3.355 0.097,0.152 10 1 2.288,4.684 2.385,4.837 0.097,0.152 10 2 2.288,4.32 2.385,4.472 0.097,0.152 10 5 2.288,3.945 2.385,4.097 0.097,0.152 10 3 2.288,3.577 2.385,3.730 0.097,0.152 10 6 2.288,0.975 2.385,1.127 0.097,0.152 10 6 2.288,0.597 2.385,0.749 0.097,0.152 10 5 5.834,0.463 6.096,0.631 0.262,0.168 10 5 V

PROCEDURE

1.CHECK MIL CONDITION
a.

Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch to ON.

OK:

MIL lights up.




OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.CHECK CONNECTION BETWEEN INTELLIGENT TESTER AND ECM
2.CHECK CONNECTION BETWEEN INTELLIGENT TESTER AND ECM
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the tester on.


d.

Check for communication between the tester and ECM.

Result
Result Proceed to
Communication is not possible A
Communication is possible B



A

3.CHECK MIL (THROTTLE POSITION SENSOR)

B

3.CHECK MIL (THROTTLE POSITION SENSOR)
a.

Disconnect the throttle with motor body assembly connector.


b.

Turn the ignition switch to ON.


c.

Check the MIL.

Result
Result Proceed to
MIL does not illuminate A
MIL illuminates B



A

4.CHECK MIL (ACCELERATOR PEDAL POSITION SENSOR)

B

REPLACE THROTTLE WITH MOTOR BODY ASSEMBLY

4.CHECK MIL (ACCELERATOR PEDAL POSITION SENSOR)
a.

Disconnect the accelerator pedal sensor assembly connector.


b.

Turn the ignition switch to ON.


c.

Check the MIL.

Result
Result Proceed to
MIL does not illuminate A
MIL illuminates B



A

5.CHECK HARNESS AND CONNECTOR (VC CIRCUIT)

B

REPLACE ACCELERATOR PEDAL SENSOR ASSEMBLY

5.CHECK HARNESS AND CONNECTOR (VC CIRCUIT)
a.

Disconnect the throttle with motor body assembly connector.


b.

Disconnect the accelerator pedal sensor assembly connector.


c.

Disconnect the ECM connectors.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B84-67 (VCTA) or B29-5 (VC) - Body ground Always 10 kΩ or higher
A74-57 (VCPA) or A36-4 (VCPA) - Body ground Always 10 kΩ or higher
A74-58 (VCP2) or A36-1 (VCP2) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR