HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Manual Air Conditioning System)  Recirculated/Fresh Air Modes do not Switch  


DESCRIPTION

If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.

Symptom Factor
Air inlet mode cannot be changed between recirculation/fresh
·

No. 1 blower damper servo sub-assembly malfunction

·

No. 2 heater control sub-assembly malfunction

·

Damper and damper link

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly malfunction

·

Harness or connector



WIRING DIAGRAM

E437278E01
0.594,0.521 1.729,0.802 1.135,0.281 10 false ECU-IGP NO. 3 1.365,1.823 3.135,2.115 1.771,0.292 10 false Recirculation/Fresh Switch 2.969,1.115 3.365,1.406 0.396,0.292 10 false +IG 3.448,1.115 3.844,1.406 0.396,0.292 10 false F/R 2.427,1.354 2.823,1.646 0.396,0.292 10 false OFF 2.458,1.583 2.854,1.875 0.396,0.292 10 false ON 0.927,1.938 1.333,2.229 0.406,0.292 10 false IG+ 0.74,1.938 0.969,2.167 0.229,0.229 10 false 5 3.833,2.729 4.188,2.969 0.354,0.24 10 false F/R 3.76,3.24 4.188,3.458 0.427,0.219 10 false FRID 1.948,0.365 3.083,0.646 1.135,0.281 10 false from IGP Relay 4.219,2.74 4.469,2.979 0.25,0.24 10 false 3 4.208,3.25 4.427,3.5 0.219,0.25 10 false 2 5.531,2.74 5.792,3 0.26,0.26 10 false 33 5.542,3.24 5.802,3.458 0.26,0.219 10 false 22 5.813,2.844 6.156,3.083 0.344,0.24 10 false FR 5.813,3.375 6.313,3.677 0.5,0.302 10 false LREC 1.5,3.74 1.917,3.938 0.417,0.198 10 false H63 1.5,3.917 3.813,4.292 2.313,0.375 10 false No. 2 Heater Control Sub-assembly 5.521,6.667 5.938,6.865 0.417,0.198 10 false H23 5.521,6.844 7.073,7.302 1.552,0.458 10 false Air Conditioning Amplifier Assembly 0.698,6.688 1.115,6.885 0.417,0.198 10 false H36 5.802,5.865 6.229,6.094 0.427,0.229 10 false AIR 2.698,5.75 3.198,6.021 0.5,0.271 10 false MREC 3.198,5.76 3.5,5.958 0.302,0.198 10 false 1 5.552,5.74 5.854,5.938 0.302,0.198 10 false 23 3.198,4.854 3.448,5.052 0.25,0.198 10 false 4 2.948,4.844 3.229,5.094 0.281,0.25 10 false IG 5.813,5.406 6.229,5.677 0.417,0.271 10 false AIRF 5.615,5.292 5.833,5.479 0.219,0.188 10 false 6 2.76,5.302 3.229,5.521 0.469,0.219 10 false MR/F 3.198,5.302 3.5,5.5 0.302,0.198 10 false 3 5.802,6.313 6.198,6.552 0.396,0.24 10 false AIF 3.198,6.198 3.427,6.427 0.229,0.229 10 false 2 2.708,6.198 3.177,6.438 0.469,0.24 10 false MFRS 5.625,6.188 5.823,6.365 0.198,0.177 10 false 7 0.698,6.865 3.375,7.146 2.677,0.281 10 false No. 1 Blower Damper Servo Sub-assembly 3.688,6.708 5.24,7.24 1.552,0.531 10 false Air Conditioning Harness Assembly

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
a.

Check that the No. 1 blower damper servo sub-assembly is installed correctly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY

OK:

The No. 1 blower damper servo sub-assembly is installed correctly.



Result:
Proceed to
OK
NG



OK

2.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

2.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
a.

Remove the No. 1 blower damper servo sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY


b.
E439701C01
0.552,0.313 0.969,0.552 0.417,0.24 0.177,1.906 0.49,2.104 0.313,0.198 10 false *b 2.323,3.146 2.625,3.323 0.302,0.177 10 false *c 0.177,0.083 0.49,0.281 0.313,0.198 10 false *a 2.354,0.667 2.667,0.865 0.313,0.198 10 false *d 0.719,2.802 1.031,3 0.313,0.198 10 false *e 3.135,1.823 3.292,2.073 0.156,0.25 10 false *f 0.646,0.344 1.104,0.542 0.458,0.198 10 false H36
*a Component without harness connected
(No. 1 Blower Damper Servo Sub-assembly)
*b A position
*c B position
*d C position
*e 0° to 120°
*f 120° to 240°


Inspect the No. 1 blower damper servo sub-assembly.

OK:
Condition Specified Condition
Auxiliary Battery (+) → H36-4 (IG)
Auxiliary Battery (-) → H36-1 (MREC)
Rotate to A position
Auxiliary Battery (+) → H36-4 (IG)
Auxiliary Battery (-) → H36-3 (MR/F)
Rotate to B position
Auxiliary Battery (+) → H36-4 (IG)
Auxiliary Battery (-) → H36-2 (MFRS)
Rotate to C position



Result:
Proceed to
OK
NG



OK

3.INSPECT NO. 2 HEATER CONTROL SUB-ASSEMBLY

NG

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

3.INSPECT NO. 2 HEATER CONTROL SUB-ASSEMBLY

OK

4.CHECK HARNESS AND CONNECTOR (NO. 2 HEATER CONTROL SUB-ASSEMBLY - IG POWER SOURCE)

NG

4.CHECK HARNESS AND CONNECTOR (NO. 2 HEATER CONTROL SUB-ASSEMBLY - IG POWER SOURCE)
a.

Disconnect the H63 No. 2 heater control sub-assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
H63-5 (IG+) - Body ground Ignition switch off Below 1 V
H63-5 (IG+) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (NO. 2 HEATER CONTROL SUB-ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (NO. 2 HEATER CONTROL SUB-ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the H23 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H63-2 (FRID) - H23-22 (LREC) Always Below 1 Ω
H63-3 (F/R) - H23-33 (FR) Always Below 1 Ω
H63-2 (FRID) - H23-22 (LREC) - Other terminals and body ground Always 10 kΩ or higher
H63-3 (F/R) - H23-33 (FR) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.CHECK HARNESS AND CONNECTOR (NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY - IG POWER SOURCE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY - IG POWER SOURCE)
a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
H36-4 (IG) - Body ground Ignition switch off Below 1 V
H36-4 (IG) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

7.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H36-1 (MREC) - H23-23 (AIR) Always Below 1 Ω
H36-2 (MFRS) - H23-7 (AIF) Always Below 1 Ω
H36-3 (MR/F) - H23-6 (AIRF) Always Below 1 Ω
H36-1 (MREC) or H23-23 (AIR) - Other terminals and body ground Always 10 kΩ or higher
H36-2 (MFRS) or H23-7 (AIF) - Other terminals and body ground Always 10 kΩ or higher
H36-3 (MR/F) or H23-6 (AIRF) - Other terminals and body ground Always 10 kΩ or higher



Result:
Result Proceed to
OK A
NG (for LHD) B
NG (for RHD) C



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C