The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position, which controls the air inlet switching.
The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B143B7F | Air Inlet Damper Control Servo Motor Actuator Stuck Off | Diagnosis Condition:
No. 1 blower damper servo sub-assembly operating Malfunction Status: Damper servo operation request signals are output but the damper position sensor value does not change or abnormal Detection Time: Continuously for 30 seconds or more |
·
No. 1 blower damper servo sub-assembly ·
Air conditioning harness assembly ·
Air conditioning radiator assembly |
Memorized |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | No. 1 blower damper servo sub-assembly operating | ○ | ○ |
| Malfunction | Damper servo operation request signals are output but the damper position sensor value does not change | ○ | - |
| Damper servo operation request signals are output but the damper position sensor value is abnormal | - | ○ | |
| Detection Time | Continuously for 30 seconds or more | Continuously for 30 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored
for Dual Type
for Single Type
This DTC is also output for the damper link, damper lock, etc. Before performing inspection, perform servomotor initialization and check that there are no mechanical malfunctions.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>INITIALIZATION
This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>INITIALIZATION
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Check for DTCs.
| Result | Proceed to |
|---|---|
| B14037F, B14067F and B143B7F are output | A |
| Only B143B7F is output | B |
A
B
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Tester Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Result | Proceed to |
|---|---|
| No. 1 air conditioning radiator damper servo sub-assembly operates | A |
| No. 1 air conditioning radiator damper servo sub-assembly does not operate at all | B |
A
B
Check that the No. 1 blower damper servo sub-assembly is installed correctly.
The No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for a wire harness caught between the links of the motors and dampers.
No wire harnesses are caught between the links of the motors and dampers.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the No. 1 blower damper servo sub-assembly.
Procedure1
Operate the air inlet dampers by hand.
The air inlet dampers are easily operated by hand.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h7-1 (M-) - h4-5 (M-) | Always | Below 1 Ω |
| h7-2 (M+) - h4-4 (M+) | Always | Below 1 Ω |
| h7-3 (STE2) - h4-3 (sigB) | Always | Below 1 Ω |
| h7-4 (STE1) - h4-2 (sigA) | Always | Below 1 Ω |
| h7-5 (GND) - h4-1 (GND) | Always | Below 1 Ω |
| h7-1 (M-) or h4-5 (M-) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-2 (M+) or h4-4 (M+) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Check for DTCs.
| Result | Proceed to |
|---|---|
| B14037F, B14067F and B143B7F are output | A |
| Only B143B7F is output | B |
A
B
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Tester Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Result | Proceed to |
|---|---|
| No. 1 air conditioning radiator damper servo sub-assembly operates | A |
| No. 1 air conditioning radiator damper servo sub-assembly does not operate at all | B |
A
B
Check that the No. 1 blower damper servo sub-assembly is installed correctly.
The No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for a wire harness caught between the links of the motors and dampers.
No wire harnesses are caught between the links of the motors and dampers.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the No. 1 blower damper servo sub-assembly.
Procedure1
Operate the air inlet dampers by hand.
The air inlet dampers are easily operated by hand.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h7-1 (M-) - h4-5 (M-) | Always | Below 1 Ω |
| h7-2 (M+) - h4-4 (M+) | Always | Below 1 Ω |
| h7-3 (STE2) - h4-3 (sigB) | Always | Below 1 Ω |
| h7-4 (STE1) - h4-2 (sigA) | Always | Below 1 Ω |
| h7-5 (GND) - h4-1 (GND) | Always | Below 1 Ω |
| h7-1 (M-) or h4-5 (M-) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-2 (M+) or h4-4 (M+) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG