Refer to DTC P013611.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P013611
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P013613 | O2 Sensor Circuit Bank 1 Sensor 2 Circuit Open | All of the following conditions are met (3 trip detection logic): (a)
100 seconds have elapsed since heated oxygen sensor (sensor 2) dew point judgment* was completed. (b)
Heated oxygen sensor (sensor 2) output voltage is between 1.25 and 3.5 V. (c)
Conditions (a) and (b) are met continuously for 5 seconds. (d)
Active air-fuel ratio control is performed as follows after condition (c) is met: (1)
Pulse signal is applied to heated oxygen sensor (sensor 2) signal line. (2)
Heated oxygen sensor (sensor 2) voltage is measured after pulse signal is applied. (3)
Heated oxygen sensor (sensor 2) voltage after pulse signal applied is 2.8 V or higher. (4)
When condition (3) is met, steps (1) and (2) are repeated 2 more times. (e)
Average difference in heated oxygen sensor (sensor 1) output voltage when active air-fuel ratio control is performed 3 times is 2.8 V or higher. |
·
Open in heated oxygen sensor (sensor 2) circuit ·
Heated oxygen sensor (sensor 2) |
Comes on | DTC stored | Engine | A |
*: Condensation may form in the exhaust pipes after the engine is started and before the exhaust system has warmed up. If condensation exists, the sensor element may be damaged if the heated oxygen sensor (sensor 2) heater is heated excessively. Therefore, the ECM will restrict the output of the heated oxygen sensor (sensor 2) heater until it determines condensation is not forming in the exhaust pipes. Dew point judgment is when the ECM judges that condensation is no longer forming.
Refer to DTC P013013.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P013013
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
DTC P013613 is detected when the vehicle is driven at an average vehicle speed of approximately 50 km/h (31 mph) in an urban area for approximately 30 minutes.
After replacing the ECM, perform idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
The internal resistance of the heated oxygen sensor (sensor 2) cannot be measured using a tester.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Pre-procedure1
Warm up the heated oxygen sensor (sensor 2) at an engine speed of 2500 rpm for approximately 3 minutes.
Procedure1
Read the output voltage of the heated oxygen sensor (sensor 2) during racing the engine.
| Tester Display |
|---|
| O2 Sensor Voltage B1S2 |
Fluctuates between less than 0.4 V, and higher than 0.55 V (see the following figure).
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
None.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for at least 30 seconds.
NEXT
Pre-procedure1
Start the engine and warm it up.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Procedure1
Read the pending DTCs.
| Result | Proceed to |
|---|---|
| DTC P013613 is output | A |
| DTCs are not output | B |
Post-procedure1
None.
A
B
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>HEATED OXYGEN SENSOR (for Sensor 2)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for at least 30 seconds.
NEXT
Pre-procedure1
Start the engine and warm it up.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Procedure1
Read the pending DTCs.
| Result | Proceed to |
|---|---|
| P013613 is output | A |
| DTCs are not output | B |
Post-procedure1
None.
A
B
Pre-procedure1
Disconnect the heated oxygen sensor (sensor 2) connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D85-4 (OX1B) - D50-124 (OX1B) | Always | Below 1 Ω |
| D85-2 (HT1B) - D50-24 (HT1B) | Always | Below 1 Ω |
| D85-3 (E1) - D50-123 (E12) | Always | Below 1 Ω |
| D85-4 (OX1B) or D50-124 (OX1B) - Body ground | Always | 10 kΩ or higher |
| D85-2 (HT1B) or D50-24 (HT1B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>HEATED OXYGEN SENSOR (for Sensor 2)>REMOVAL
NG