Refer to DTC P245211.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P245211
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P245215 | Particulate Filter Pressure Sensor "A" Circuit Short to Battery or Open | The output voltage from the differential pressure sensor is 4.822 V or higher for 0.5 seconds or more (1 trip detection logic). | ·
Open or short in differential pressure sensor circuit ·
Differential pressure sensor ·
ECM |
Comes on | DTC stored (Euro-OBD)
- (except Euro-OBD) |
Engine | A |
When a DTC is output, check the Data List item "GPF Differential Pressure Sensor Bank 1" using the GTS.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>DATA LIST / ACTIVE TEST
| DTC No. | GPF Differential Pressure Sensor Bank 1 | Malfunction |
|---|---|---|
| P245215 | 150 kPa [21.8 psi] or higher | ·
Short in VCPX circuit to PEX circuit ·
Open in PEX circuit ·
Open in EPEX circuit |
If the Data List displays a normal value, the normal value may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.
In order to detect abnormality in the differential pressure sensor, the ECM always monitors the output voltage from the sensor. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the sensor circuit.
Example:
When the sensor output voltage is higher than 4.822 V for 0.5 seconds or more, the ECM stores a DTC.
| Frequency of Operation | Continuous |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the GTS on.
Start the engine and wait 5 seconds or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the pending DTCs.
Refer to DTC P245211.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P245211
After replacing the ECM, perform idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
Pre-procedure1
Disconnect the differential pressure sensor connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D72-3 (VC) - D72-1 (E2) | Ignition switch ON | 4.5 to 5.5 V |
| D72-2 (PEX) - D72-1 (E2) | Ignition switch ON | 3.0 to 5.5 V |
Turn the ignition switch off and wait for at least 30 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D72-3 (VC) - D72-2 (PEX) | Ignition switch off | 190 to 210 kΩ |
| D72-1 (E2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the differential pressure sensor connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D72-2 (PEX) - A55-34 (PEX) | Always | Below 1 Ω |
| D72-1 (E2) - A55-32 (EPEX) | Always | Below 1 Ω |
| D72-2 (PEX) or A55-34 (PEX) - Other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG