Home › Engine / Hybrid System › 1KR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2020.07
RM36W0E _51 Engine / Hybrid System _091054 1KR-FE ENGINE CONTROL _0431746 SFI SYSTEM C

1KR-FE ENGINE CONTROL  SFI SYSTEM  P245215  Particulate Filter Pressure Sensor "A" Circuit Short to Battery or Open  


DESCRIPTION

Refer to DTC P245211.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P245211

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory DTC Output from Priority
P245215 Particulate Filter Pressure Sensor "A" Circuit Short to Battery or Open The output voltage from the differential pressure sensor is 4.822 V or higher for 0.5 seconds or more (1 trip detection logic).
·

Open or short in differential pressure sensor circuit

·

Differential pressure sensor

·

ECM


Comes on DTC stored (Euro-OBD)
- (except Euro-OBD)
Engine A

HINT:

When a DTC is output, check the Data List item "GPF Differential Pressure Sensor Bank 1" using the GTS.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>DATA LIST / ACTIVE TEST

DTC No. GPF Differential Pressure Sensor Bank 1 Malfunction
P245215 150 kPa [21.8 psi] or higher
·

Short in VCPX circuit to PEX circuit

·

Open in PEX circuit

·

Open in EPEX circuit



If the Data List displays a normal value, the normal value may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.


MONITOR DESCRIPTION

In order to detect abnormality in the differential pressure sensor, the ECM always monitors the output voltage from the sensor. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the sensor circuit.

Example:

When the sensor output voltage is higher than 4.822 V for 0.5 seconds or more, the ECM stores a DTC.

MONITOR STRATEGY

Frequency of Operation Continuous

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON.

3.

Turn the GTS on.

4.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

5.

Turn the ignition switch off and wait for at least 30 seconds.

6.

Turn the ignition switch to ON.

7.

Turn the GTS on.

8.

Start the engine and wait 5 seconds or more.

9.

Enter the following menus: Powertrain / Engine / Trouble Codes.

10.

Read the pending DTCs.


WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:

After replacing the ECM, perform idle learning.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION


HINT:

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR
HINT:

Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.


Pre-procedure1

a.

Disconnect the differential pressure sensor connector.


b.

Turn the ignition switch to ON.


Procedure1

c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
D72-3 (VC) - D72-1 (E2) Ignition switch ON 4.5 to 5.5 V
D72-2 (PEX) - D72-1 (E2) Ignition switch ON 3.0 to 5.5 V



d.

Turn the ignition switch off and wait for at least 30 seconds.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D72-3 (VC) - D72-2 (PEX) Ignition switch off 190 to 210 kΩ
D72-1 (E2) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

f.

None.



OK

NG

2.CHECK HARNESS AND CONNECTOR (DIFFERENTIAL PRESSURE SENSOR - ECM)
2.CHECK HARNESS AND CONNECTOR (DIFFERENTIAL PRESSURE SENSOR - ECM)

Pre-procedure1

a.

Disconnect the differential pressure sensor connector.


b.

Disconnect the ECM connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D72-2 (PEX) - A55-34 (PEX) Always Below 1 Ω
D72-1 (E2) - A55-32 (EPEX) Always Below 1 Ω
D72-2 (PEX) or A55-34 (PEX) - Other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

d.

None.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR