DESCRIPTION

If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.

Symptom Factor
Windshield frequently fogs up
·

Compressor with pulley assembly malfunction

·

Refrigerant volume (low)

·

Cooler expansion valve (opened excessively)

·

No. 1 heater control sub-assembly malfunction

·

Defroster damper control cable sub-assembly malfunction

·

Air conditioning radiator assembly malfunction



PROCEDURE

1.PERFORM REFRIGERANT SHORTAGE CHECK
a.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Blower speed HI

*1: If the ambient temperature is not within the range shown, do not perform this check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 4578
Result:
Result Amount of Refrigerant
Refrigerant correct Correct
Refrigerant shortage Insufficient


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Result Proceed to
OK A
NG (for HFC-134a(R134a)) B
NG (for HFO-1234yf(R1234yf)) C



A

2.CHECK OPERATION

B

C

2.CHECK OPERATION
a.

Set the airflow mode control switch to defrost and check that the air outlet mode changes to DEF mode.

OK:

The air outlet mode changes to DEF mode.



Result:
Result Proceed to
OK (for HFC-134a(R134a)) A
OK (for HFO-1234yf(R1234yf)) B
NG C



A

B

C

3.INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY
3.INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY

OK

4.REPLACE DEFROSTER DAMPER CONTROL CABLE SUB-ASSEMBLY

NG

4.REPLACE DEFROSTER DAMPER CONTROL CABLE SUB-ASSEMBLY
a.

Replace the defroster damper control cable sub-assembly with a new or known good one.



b.

Check if the same malfunction recurs.

OK:

Malfunction does not reoccur (returns to normal).



Result:
Result Proceed to
OK A
NG (for LHD) B
NG (for RHD) C



A

END (DEFROSTER DAMPER CONTROL CABLE SUB-ASSEMBLY WAS DEFECTIVE)

B

REPAIR OR REPLACE AIR CONDITIONING RADIATOR ASSEMBLY

C

REPAIR OR REPLACE AIR CONDITIONING RADIATOR ASSEMBLY