The engine stop and start ECU uses the park/neutral position switch assembly installed to the continuously variable transaxle assembly to detect when the shift lever is in P or N.
for CVT:
Refer to DTC P085012.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>P085012
for Manual Transaxle:
Refer to DTC P085011.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>P085011
Before replacing the engine stop and start ECU, read the number of starter operations and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU, perform learning of the external backup boost converter (eco run vehicle converter assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
for CVT:
When the engine stop and start ECU or electromagnetic oil pump is replaced, check the electromagnetic oil pump.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
For wire harness and connector inspection procedures and precautions, refer to "General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE"
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for CVT | A |
| for Manual Transaxle | B |
A
B
Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.
| Tester Display |
|---|
| Neutral Switch |
In accordance with the display on the GTS, read the Data List.
| Tester Display | Condition | Normal Condition |
|---|---|---|
| Neutral Switch | Shift lever in P or N | ON |
| Shift lever not in P or N | OFF |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>K320 (MULTIDRIVE / CVT)>PARK / NEUTRAL POSITION SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A67 engine stop and start ECU connector.
Disconnect the D45 park/neutral position switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A67-21 (STA) - D45-5 (L) | Always | Below 1 Ω |
| A67-17 (CLL) - D45-4 (B) | Always | Below 1 Ω |
| A67-21 (STA) - Body ground | Always | 80 to 180 Ω |
| A67-17 (CLL) - Body ground | Always | 10 kΩ or higher |
| D45-5 (L) - Body ground | Always | 80 to 180 Ω |
| D45-4 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.
| Tester Display |
|---|
| Neutral Switch |
Read the value when the shift lever is in neutral and any other position.
| Tester Display | Condition | Normal Condition |
|---|---|---|
| Neutral Switch | Shift lever is in neutral | ON |
| Shift lever is in any position other than neutral | OFF |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A67 engine stop and start ECU connector.
Disconnect the D44 neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A67-26 (TMVC) - D44-1 (W1) | Always | Below 1 Ω |
| A67-25 (TME2) - D44-3 (F+) | Always | Below 1 Ω |
| A67-8 (TMN) - D44-2 (TMN) | Always | Below 1 Ω |
| A67-26 (TMVC) - Body ground and other terminals | Always | 10 kΩ or higher |
| D44-1 (W1) - Body ground and other terminals | Always | 10 kΩ or higher |
| A67-25 (TME2) - Body ground and other terminals | Always | 10 kΩ or higher |
| D44-3 (F+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A67-8 (TMN) - Body ground and other terminals | Always | 10 kΩ or higher |
| D44-2 (TMN) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A67-8 (TMN) - A67-25 (TME2) | Ignition switch ON, shift lever in neutral | 2.7 to 4.3 V |
| Ignition switch ON, shift lever in any position other than neutral | 0.7 to 1.9 V |
| Result | Proceed to |
|---|---|
| OK | A |
| NG | B |
A
B
for M15A-FKS: Click hereDrivetrain>EC6E (MANUAL TRANSMISSION / TRANSAXLE)>NEUTRAL POSITION SWITCH>REMOVAL
for 1KR-FE: Click hereDrivetrain>C551 (MANUAL TRANSMISSION / TRANSAXLE)>NEUTRAL POSITION SWITCH>REMOVAL
for G16E-GTS: Click hereDrivetrain>EA67F (MANUAL TRANSMISSION / TRANSAXLE)>NEUTRAL POSITION SWITCH>REMOVAL