DTC B1123

Precautions: Precautions for Diagnosing Trouble · Precautions for Replacing Remote Controller · Precautions for Remote Controller Disposal · Precautions for Replacing Keyless Start Control Module · Precautions for Control Systems · General safety (00)

DTC Detecting Condition and Trouble Area
DTC detecting condition Trouble area
B1123: Backup Power Supply Malfunction
Backup power supply circuit voltage from “DOME” fuse is lower than specified value.
•“DOME” fuse
•Each system connected to “DOME” fuse
•Keyless start control module
DTC Confirmation Procedure
1)Set ignition “ON”.
DTC Troubleshooting
Step Action Yes No
1
Fuse check
1)Check that ignition is “OFF”.
2)Check “DOME” fuse.
Is check result OK?
Replace keyless start control module and recheck DTC. icon 
Replace “DOME” fuse and go to Step 2.
2
DTC check
1)Set ignition “ON”.
2)Check DTC. icon 
Is DTC B1123 still detected?
Go to Step 3.
End.
3
Each system check connected to “DOME” fuse
1)Check each system connected to “DOME” fuse, except keyless start control module.
Is check result OK?
Replace “DOME” fuse and keyless start control module, and recheck DTC. icon 
Repair or replace defective part and/or wire harness, and then replace “DOME” fuse and recheck DTC.