ENGINE IMMOBILISER SYSTEM (w/o Entry and Start System) > Security Indicator Light Does not Blink |

| 1.CHECK FOR DTC |
Check for DTCs (Click here).
|
| ||||
| OK | |
| 2.PERFORM ACTIVE TEST USING GTS (SECURITY INDICATOR) |
Check that the security indicator light illuminates when operating it with the Active Test (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Security Indicator | Security indicator light | ON/OFF | - |
|
| ||||
| OK | |
| 3.READ VALUE USING GTS (IG SW, KEY UNLOCK WARNING SW) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| IG SW | Ignition switch ON signal / OFF or ON | OFF: Ignition switch ACC or off ON: Ignition switch ON | - |
| Key Unlock Warning SW | Un-lock warning switch signal / OFF or ON | OFF: No key in ignition key cylinder ON: Key inserted in ignition key cylinder | - |
| Result | Proceed to |
| OK | A |
| NG (IG SW) | B |
| NG (Key Unlock Warning SW) | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 4.INSPECT UN-LOCK WARNING SWITCH ASSEMBLY |
Remove the un-lock warning switch assembly (Click here).
Inspect the un-lock warning switch assembly (Click here).
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (UN-LOCK WARNING SWITCH ASSEMBLY - MAIN BODY ECU) |
![]() |
Disconnect the D5 main body ECU (network gateway ECU) connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D53-1 (UN+) - Body ground | Always | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
| D53-2 (UN-) - D5-22 (KSW) | Always | Below 1 Ω |
| D53-2 (UN-) - Body ground | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Un-lock Warning Switch Assembly) |
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - COMBINATION METER ASSEMBLY) |
Disconnect the 3B instrument panel junction block assembly connector.
Disconnect the D7 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3B-22 - D7-18 | Always | Below 1 Ω |
| D7-40 - Body ground | Always | Below 1 Ω |
| 3B-22 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly ) | - | - |
| Tester Connection | Condition | Specified Condition |
| MB-27 (ILL) - 3B-22 | Always | Below 1 Ω |
|
| ||||
| OK | |
| 8.REPLACE COMBINATION METER ASSEMBLY |
Replace the combination meter assembly with a new one (Click here).
When the immobiliser is set, check that the security indicator light blinks.
|
| ||||
| OK | ||
| ||