Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › ENGINE IMMOBILISER SYSTEM (w/o Entry and Start System)

ENGINE IMMOBILISER SYSTEM (w/o Entry and Start System) > Security Indicator Light Does not Blink

for Preparation Click here


DESCRIPTION

  1. When the engine immobiliser system is set, the security indicator light blinks continuously, but does not illuminate if the engine immobiliser system is not set.

WIRING DIAGRAM


B311631E01


INSPECTION PROCEDURE

NOTICE:
  1. Inspect the fuses for circuits related to this system before performing the following inspection procedure.
  2. If the combination meter assembly and main body ECU (network gateway ECU) is replaced, refer to Service Bulletin.

1.CHECK FOR DTC
  1. Check for DTCs (Click here).

    OK:
    DTC is not output.



NG
GO TO DTC CHART (Click here)
OK


2.PERFORM ACTIVE TEST USING GTS (SECURITY INDICATOR)
  1. Check that the security indicator light illuminates when operating it with the Active Test (Click here).

    Main Body 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Security Indicator
    Security indicator light
    ON/OFF
    -

    OK:
    Security indicator light can be turned on and off using the GTS.



NG
Go to step 6
OK


3.READ VALUE USING GTS (IG SW, KEY UNLOCK WARNING SW)
  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Enter the following menus: Body Electrical / Main Body / Data List.

  1. Read the Data List according to the display on the GTS.

    Main Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    IG SW
    Ignition switch ON signal / OFF or ON
    OFF: Ignition switch ACC or off
    ON: Ignition switch ON
    -
    Key Unlock Warning SW
    Un-lock warning switch signal / OFF or ON
    OFF: No key in ignition key cylinder
    ON: Key inserted in ignition key cylinder
    -

OK:
On the GTS screen, the display changes between ON and OFF according to the chart above.

Result 
Result
Proceed to
OK
A
NG (IG SW)
B
NG (Key Unlock Warning SW)
C


B
GO TO LIGHTING SYSTEM (IG Signal Circuit) (Click here)

C
Go to step 4
A

REPLACE MAIN BODY ECU (NETWORK GATEWAY ECU) (Click here)  

4.INSPECT UN-LOCK WARNING SWITCH ASSEMBLY
  1. Remove the un-lock warning switch assembly (Click here).

  1. Inspect the un-lock warning switch assembly (Click here).



NG
REPLACE UN-LOCK WARNING SWITCH ASSEMBLY (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (UN-LOCK WARNING SWITCH ASSEMBLY - MAIN BODY ECU)
B314390E01
  1. Disconnect the D5 main body ECU (network gateway ECU) connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    D53-1 (UN+) - Body ground
    Always
    11 to 14 V

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    D53-2 (UN-) - D5-22 (KSW)
    Always
    Below 1 Ω
    D53-2 (UN-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Un-lock Warning Switch Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (NETWORK GATEWAY ECU) (Click here)  

6.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - COMBINATION METER ASSEMBLY)
  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Disconnect the D7 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3B-22 - D7-18
    Always
    Below 1 Ω
    D7-40 - Body ground
    Always
    Below 1 Ω
    3B-22 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.


B312640E02


Text in Illustration 
*a
Component without harness connected
(Instrument Panel Junction Block Assembly )
-
-

Standard Resistance:

Tester Connection
Condition
Specified Condition
MB-27 (ILL) - 3B-22
Always
Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK


8.REPLACE COMBINATION METER ASSEMBLY
  1. Replace the combination meter assembly with a new one (Click here).

  1. When the immobiliser is set, check that the security indicator light blinks.

OK:
Security indicator light blinks.



NG
REPLACE MAIN BODY ECU (NETWORK GATEWAY ECU) (Click here)
OK

END (COMBINATION METER ASSEMBLY WAS DEFECTIVE)