Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298709 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) S

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  DIAGNOSTIC TROUBLE CODE CHART  


AIR CONDITIONING SYSTEM
DTC No. Detection Item DTC Detection Condition Link
B1412 Ambient Temperature Sensor Circuit When the air conditioning amplifier assembly receives out-of-range outside temperature sensor data from the combination meter assembly. Click here
B1413 Evaporator Temperature Sensor Circuit Any of the following conditions is met:
·

Open in No. 1 cooler thermistor (evaporator temperature sensor) circuit

·

Short in No. 1 cooler thermistor (evaporator temperature sensor) circuit


Click here
B1423 Pressure Sensor Circuit Any of the following conditions is met:
·

Open in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)

·

Short in air conditioner pressure sensor circuit (Only when the outside temperature is 5 °C (41°F) or more)

·

for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)

·

for HFC-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPa (28.7 kgf/cm2, 408 psi) or more) (Only when the outside temperature is 5 °C (41°F) or more)


Click here
B1441 Air Mix Damper Control Servo Motor Circuit (Passenger Side) Any of the following conditions is met:
·

No. 1 air conditioning radiator damper servo sub assembly (upper air mix) drive terminal is open circuit

·

No. 1 air conditioning radiator damper servo sub assembly (upper air mix) drive terminal is short circuit


Click here
B1442 Air Inlet Damper Control Servo Motor Circuit Any of the following conditions is met:
·

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is open circuit

·

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is short circuit


Click here
B1443 Air Outlet Damper Control Servo Motor Circuit Any of the following conditions is met:
·

No. 2 air conditioning radiator damper servo sub-assembly (mode switching) drive terminal is open circuit

·

No. 2 air conditioning radiator damper servo sub-assembly (mode switching) drive terminal is short circuit


Click here
B1451 Compressor Solenoid Circuit Any of the following conditions is met:
·

Open in compressor solenoid circuit

·

Short in compressor solenoid circuit


Click here
B1454 Air Outlet Damper Cool Control Servo Motor Circuit (Passenger Side) Any of the following conditions is met:
·

No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) drive terminal is open circuit

·

No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) drive terminal is short circuit


Click here
B14B2 Lost Communication with Front Panel LIN Lost communication with air conditioning control assembly Click here
U0100 Lost Communication with ECM No communication with ECM Click here
U0131 Lost Communication with Electric Power Steering ECU No communication with power steering ECU assembly Click here
U0142 Lost Communication with Main Body ECU No communication with main body ECU (multiplex network body ECU) Click here
U0155 Lost Communication with Combination Meter No communication with combination meter assembly Click here