SRS Warning Light Remains ON
Circuit diagnosis · Vehicles built from Jun 2009
Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009
DESCRIPTION
The SRS warning light is located on the combination meter assembly.When the SRS is normal, the SRS warning light comes on for approximately 6 seconds after the ignition switch is turned from off to on (IG) position, and then goes off automatically.
If there is a malfunction in the SRS, the SRS warning light comes on to inform the driver of a problem.
When terminals TC and CG of the DLC3 are connected, the DTC is displayed by blinks of the SRS warning light.
The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the center airbag sensor assembly in case the source voltage drops.
When the battery voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to normal voltage.
A malfunction in this circuit is not recorded in the center airbag sensor assembly. The SRS warning light automatically goes off when the source voltage returns to normal.
The signal to illuminate the SRS warning light is transmitted from the center airbag sensor assembly to the combination meter assembly through the CAN communication system.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CAN COMMUNICATION SYSTEM |
Use the intelligent tester to check if the CAN communication system is functioning normally.
- HINT:
- The center airbag sensor assembly is connected to the CAN communication system. Therefore, before starting troubleshooting, make sure to check that there is no trouble in the CAN communication system.
- Refer to the "Bus Check" for CAN communication system.
-
Click here for LHD with Smart Entry and Start System
-
Click here for LHD with Smart Entry and Start System
-
Click here for LHD without Smart Entry and Start System
-
Click here for LHD without Smart Entry and Start System
-
Click here for RHD with Smart Entry and Start System
-
Click here for RHD with Smart Entry and Start System
-
Click here for RHD without Smart Entry and Start System
-
Click here for RHD without Smart Entry and Start System
- Result:
Condition
Proceed to
DTC is not output
A
DTC is output
B
|
|
||||
| A | |
| 2. CHECK BATTERY |
Measure the voltage of the battery.
- Standard voltage:
- 11 to 14 V
|
|
||||
| OK | |
| 3. CHECK CONNECTORS |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor assembly and combination meter assembly.
- OK:
- The connectors are properly connected.
|
|
||||
| OK | |
| 4. CHECK WIRE HARNESS (CENTER AIRBAG SENSOR ASSEMBLY - BODY GROUND) |
Disconnect the connectors from the center airbag sensor assembly.

Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Operate all components of the electrical systems (defogger, wipers, headlights, heater blower, etc.).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E30-21 (IG2) - Body ground
Ignition switch on (IG)
10 to 14 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E30-25 (E1) - Body ground
Always
Below 1 Ω
E30-26 (E2) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 5. CHECK WIRE HARNESS (COMBINATION METER ASSEMBLY - BODY GROUND) |
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

Disconnect the F1 connector from the combination meter assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
F1-1 (B) - Body ground
Always
10 to 14 V
F1-13 (IG+) - Body ground
Ignition switch on (IG)
10 to 14 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
F1-12 (E2) - Body ground
Always
Below 1 Ω
F1-24 (ES) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 6. CHECK SRS WARNING LIGHT |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Connect the connector to the combination meter assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Check the SRS warning light condition.
- OK:
- After the primary check period, the SRS warning light goes off for approximately 10 seconds, and then remains on.
- HINT:
- The primary check period shows approximately 6 seconds after the ignition switch is turned on (IG).
- Result:
Result
Proceed to
NG
A
OK (for 2GR-FE RHD)
B
OK (except 2GR-FE RHD)
C
|
|
||||
|
|
||||
| A | ||
| ||