The combination meter sub-assembly uses the fuel sender gauge assembly to determine the level of the fuel in the fuel tank. The resistance of the fuel sender gauge assembly will vary between approximately 15 Ω with the float at the full position, and 410 Ω with the float at the empty position. The combination meter sub-assembly outputs battery voltage through two resistors that are mounted inside the combination meter sub-assembly. The combination meter sub-assembly measures the voltage between the variable resistor in the fuel sender gauge and the two resistors mounted in the meter. Voltage measured at this point will vary as the float of the fuel sender gauge is moved. The highest voltage observed should be approximately half of the battery voltage.
The fuel level warning light will come on when the fuel level is below 9.8 liters (10.4 US qts, 8.6 Imp. qts).
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| w/o Multi-information Display | A |
| w/ Multi-information Display | B |
A
B
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Fuel Meter Operation | Fuel receiver gauge | Sender E / Empty / Warning / 1/4 / 1/2 / 3/4 / Full / Sender F | Value selected during ACTIVE TEST is displayed |
Fuel receiver gauge indication is normal.
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Fuel Input | Fuel input / Min.: 0 L, Max.: 127.5 L | w/ Multi-information Display:
Fuel receiver gauge indicates F: 59.6 L Fuel receiver gauge indicates 3/4: 50.1 L Fuel receiver gauge indicates 1/2: 35.9 L Fuel receiver gauge indicates 1/4: 21.6 L Fuel receiver gauge indicates E: 6.5 L w/o Multi-information Display:
Fuel receiver gauge indicates F: 58.5 L Fuel receiver gauge indicates 1/2: 32.5 L Fuel receiver gauge indicates E: 6.5 L |
- |
| Result | Proceed to |
|---|---|
| Fuel level data displayed on the GTS is almost the same as the fuel receiver gauge indication. | A |
| Fuel level data displayed on the GTS differs from the fuel receiver gauge indication. | B |
A
B
Disconnect the G28 combination meter sub-assembly connector.
Disconnect the M17 fuel suction tube with pump and gauge assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G28-27 (L) - M17-1 | Always | Below 1 Ω |
| G28-27 (L) or M17-1 - Body ground | Always | 10 kΩ or higher |
| G28-30 (FE) - M17-2 | Always | Below 1 Ω |
| G28-30 (FE) or M17-2 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the fuel sender gauge assembly (see page Engine / Hybrid System>2AZ-FE FUEL>FUEL PUMP>REMOVAL for 2AZ-FE, see page Engine / Hybrid System>2GR-FE FUEL>FUEL PUMP>DISASSEMBLY for 2GR-FE).
Check that the float moves smoothly between E and F.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Float level is F (upper) | 13.5 to 16.5 Ω |
| 1 - 2 | Float level is between F (upper) and E (lower) | 13.5 to 414.5 Ω (Gradually changes) |
| 1 - 2 | Float level is E (lower) | 405.5 to 414.5 Ω |
| *a | Front view of wire harness connector
(to Fuel Sender Gauge Assembly) |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for 2AZ-FE) | B |
| NG (for 2GR-FE) | C |
A
B
C
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M17-1 - A-2 | Always | Below 1 Ω |
| M17-2 - A-1 | Always | Below 1 Ω |
| *a | Component without harness connected
(Fuel Suction Tube with Pump and Gauge Assembly) |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for 2AZ-FE) | B |
| NG (for 2GR-FE) | C |
A
B
C