2011-2016 FJ Cruiser · Service Manual ENGINE

P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built from Aug 2014

Also covers:

Versions by build date: Dec 2007 – Jul 2009 Aug 2009 – Jul 2014 from Aug 2014

DESCRIPTION

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air fuel ratio must be precisely controlled so that it is always close to the stoichiometric air fuel ratio. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel ratio, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air fuel ratio control.
A115539E27
DTC No.
DTC Detection Condition
Trouble Area
P0136*1
P0156*1
  1. Abnormal voltage output:
    During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic):
    1. (a) Heated oxygen sensor voltage does not increase to more than 0.59 V
    1. (b) Heated oxygen sensor voltage does not decrease to less than 0.21 V
  1. Open or short in heated oxygen sensor (bank 1, 2 sensor 2) circuit
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Heated oxygen sensor heater (bank 1, 2 sensor 2)
  4. Air fuel ratio sensor (bank 1, 2 sensor 1)
  5. Gas leak from exhaust system
  6. EFI relay
P0137
P0157
  1. Low voltage (open):
    During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic):
    1. (a) Heated oxygen sensor voltage output less than 0.21 V
    1. (b) Target air fuel ratio rich
  1. Open in heated oxygen sensor (bank 1, 2 sensor 2) circuit
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Heated oxygen sensor heater (bank 1, 2 sensor 2)
  4. Gas leak from exhaust system
  5. EFI relay
P0138*1
P0158*1
  1. High voltage (short):
    During active air fuel ratio control, following conditions (a) and (b) met for certain period of time (2 trip detection logic):
    1. (a) Heated oxygen sensor voltage output more than 0.59 V
    1. (b) Target air fuel ratio lean
  1. Short in heated oxygen sensor (bank 1, 2 sensor 2) circuit
  2. Heated oxygen sensor (bank 1, 2 sensor 2)
  3. Air fuel ratio sensor (bank 1, 2 sensor 1)
  4. ECM
  1. *1: for Euro-OBD Vehicle

MONITOR DESCRIPTION

  1. Active Air Fuel Ratio Control
    The ECM usually performs air fuel ratio feedback control so that the air fuel ratio sensor output indicates a near stoichiometric air fuel ratio. This vehicle includes active air fuel ratio control in addition to regular air fuel ratio control. The ECM performs active air fuel ratio control to detect any deterioration in the Three-Way Catalytic Converter (TWC) and heated oxygen sensor malfunctions (refer to the diagram below).
    Active air fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air fuel ratio control, the air fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, a DTC is stored.
  1. Abnormal Voltage Output of Heated Oxygen Sensor (DTC P0136 and P0156)
    While the ECM is performing active air fuel ratio control, the air fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the heated oxygen sensor voltage does not decrease to less than 0.21 V and does not increase to more than 0.59 V during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormal and stores DTC P0136 or P0156.
    A152942E68
  1. Open in Heated Oxygen Sensor Circuit (DTC P0137 and P0157)
    During active air fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air fuel ratio to become rich or lean. If the heated oxygen sensor has an open, or the voltage output of the sensor decreases significantly, the OSC indicates an extraordinarily high value. Even if the ECM attempts to continue regulating the air fuel ratio to become rich or lean, the heated oxygen sensor output does not change.
    1. While performing active air fuel ratio control, when the target air fuel ratio is rich and the heated oxygen sensor voltage output is 0.21 V or less (lean), the ECM interprets this as an abnormally low sensor output voltage and stores DTC P0137 or P0157.

    HINT:
    for Euro-OBD vehicle:
    The TWC has the capability to store oxygen. The OSC and the emission purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value (Click here).

    A329618E01
  1. Short in Heated Oxygen Sensor Circuit (P0138 and P0158)
    During active air fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air fuel ratio to become rich or lean. If the heated oxygen sensor has an short, or the voltage output of the sensor decreases significantly, the OSC indicates an extraordinarily high value. Even if the ECM attempts to continue regulating the air fuel ratio to become rich or lean, the heated oxygen sensor output does not change.
    1. When the target air fuel ratio is lean and the voltage output is 0.59 V or more (rich) during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormally high, and stores DTC P0138 or P0158.

    HINT:
    The TWC has the capability to store oxygen. The OSC and the emission purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value (Click here).

    A329619E01

CONFIRMATION DRIVING PATTERN

  1. P0136, P0137, P0138, P0156, P0157 and P0158
A199376E01
  1. Connect the intelligent tester to the DLC3.
  2. Turn the ignition switch to ON.
  3. Turn the tester on.
  4. Clear the DTCs.
  5. Turn the ignition switch off and wait for at least 30 seconds.
  6. Turn the ignition switch to ON and turn the tester on [A].
  7. Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [B].
  8. With the shift lever in D (for Automatic Transmission) or 4th gear (for Manual Transmission) or higher, drive the vehicle at 60 to 120 km/h (40 to 75 mph) for 10 minutes or more [C].

    CAUTION:
    When performing the confirmation driving pattern, obey all speed limits and traffic laws.

  9. Enter the following menus: Powertrain / Engine and ECT / DTC / Pending [D].
  10. Read the DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  11. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  12. Input the DTC: P0136, P0137, P0138, P0156, P0157 or P0158.
  13. Check the DTC judgment result.
    Tester Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    UNKNOWN
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shown ABNORMAL, the system has malfunction.
    2. If the judgment result shows INCOMPLETE or UNKNOWN, perform steps [C] through [D].


WIRING DIAGRAM

A329617E01

INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Intelligent tester only:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using the intelligent tester.
  1. Connect the intelligent tester to the DLC3.
  2. Start the engine.
  3. Turn the tester on.
  4. Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
  5. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
  6. Perform the Active Test operation with the engine in an idling condition (press the -12.5% or 12.5% button to change the fuel injection volume).
  7. Monitor the output voltages of the air fuel ratio sensor and heated oxygen sensor (AFS Voltage B1S1 and O2S B1S2 or AFS Voltage B2S1 and O2S B2S2) displayed on the tester.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.

Tester Display (Sensor)
Injection Volume
Status
Voltage
AFS Voltage B1S1
AFS Voltage B2S1
(Air Fuel Ratio)
12.5%
Rich
Below 3.1 V
-12.5%
Lean
Higher than 3.4 V
O2S B1S2
O2S B2S2
(Heated Oxygen)
12.5%
Rich
Higher than 0.55 V
-12.5%
Lean
Below 0.4 V

NOTICE:
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

Case
Air Fuel Ratio Sensor (Sensor 1) Output Voltage
Heated Oxygen Sensor (Sensor 2) Output Voltage
Main Suspected Trouble Area
1
A150787E11
A151324E08
A150787E11
A150788E06
-
2
A150787E11
A150790E01
A150787E11
A150788E06
  1. Air fuel ratio sensor
  2. Air fuel ratio sensor heater
  3. Air fuel ratio sensor circuit
3
A150787E11
A151324E08
A150787E11
A150790E01
  1. Heated oxygen sensor
  2. Heated oxygen sensor heater
  3. Heated oxygen sensor circuit
4
A150787E11
A150790E01
A150787E11
A150790E01
  1. Injector
  2. Fuel pressure
  3. Gas leak from exhaust system (air fuel ratio extremely rich or lean)

HINT:
  1. Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio sensor and heated oxygen sensor.
  2. To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / AFS Voltage B1S1 and O2S B1S2 or AFS Voltage B2S1 and O2S B2S2.
  3. Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
  4. If the OX1B wire from the ECM connector is short-circuited to the +B wire, DTC P0136 will be store.
  5. If the OX2B wire from the ECM connector is short-circuited to the +B wire, DTC P0156 will be store.


1. READ OUTPUT DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result 
    Result
    Proceed to
    P0138 or P0158 is output
    A
    P0137 or P0157 is output
    B
    P0136 or P0156 is output
    C



B
Go to step 9

C
Go to step 7
A


2. READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / O2S B1S2 or O2S B2S2.

  1. Allow the engine to idle.

  1. Read the heated oxygen sensor output voltage while idling.

    Result 
    Result
    Proceed to
    1.0 V or higher
    A
    Below 1.0 V
    B



B
Go to step 5
A


3. INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)
A240070E01
  1. Disconnect the B54 and B34 heated oxygen sensor connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (+B) - 3 (OX1B)
    Always
    10 kΩ or higher
    2 (+B) - 3 (OX2B)
    Always
    10 kΩ or higher
    2 (+B) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Component without harness connected
    (Heated Oxygen Sensor (bank 1))
    *2
    Component without harness connected
    (Heated Oxygen Sensor (bank 2))



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)
  1. Turn the ignition switch off and wait for 5 minutes.

  1. Disconnect the B50 and B47 ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B50-12 (HT1B) - B47-2 (OX1B)
    Always
    10 kΩ or higher
    B50-13 (HT2B) - B47-4 (OX2B)
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

5. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.

NOTICE:
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%
  2. The air fuel ratio sensor is displayed as AFS Voltage B1S1 or AFS Voltage B2S1, and the heated oxygen sensor is displayed as O2S B1S2 or O2S B2S2 on the tester.

  3. If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.
    Result 
    Tester Display (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1
    AFS Voltage B2S1
    Alternates between more and less than 3.3 V
    OK
    Remains at more than 3.3 V
    NG
    Remains at less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2 or O2S B2S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or more than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


    A121606E64



NG
Go to step 15
OK


6. INSPECT AIR FUEL RATIO SENSOR

HINT:
This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut operation. When the sensor is normal, the sensor current will indicate below 3.0 mA (w/o Secondary Air Injection System) or 2.2 mA (w/ Secondary Air Injection System) in this test.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Drive the vehicle by the drive pattern as listed below:

    1. Warm up the engine until the engine coolant temperature reaches 75°C (167°F) or more.

    2. Drive the vehicle at 60 km/h (37 mph) or more, and decelerate the vehicle for 5 seconds or more.

    3. Repeat the deceleration above at least 3 times.A166581E46

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / AFS Current B1S1.

  1. Read the value of the air fuel ratio sensor current while the fuel-cut operation is performed.

    Standard Current:
    w/o Secondary Air Injection System:
    Less than 3.0 mA
    w/ Secondary Air Injection System:
    Less than 2.2 mA

    HINT:
    1. To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
    2. If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the intelligent tester.



OK
Go to step 12

NG
Go to step 15
7. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / O2S B1S2 or O2S B2S2.

  1. Change the fuel injection volume using the tester, monitoring the voltage output of the heated oxygen sensors displayed on the tester.

    NOTICE:
    The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

    HINT:
    The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.

    Standard voltage:
    Fluctuates between 0.4 V or less and 0.55 V or more.



NG
Go to step 9
OK


8. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.

NOTICE:
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
  2. The air fuel ratio sensor is displayed as AFS Voltage B1S1 or AFS Voltage B2S1, and the heated oxygen sensor is displayed as O2S B1S2 or O2S B2S2 on the intelligent tester.

  3. If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.
    Result 
    Tester Display (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1
    AFS Voltage B2S1
    Alternates between more and less than 3.3 V
    OK
    Remains at more than 3.3 V
    NG
    Remains at less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2 or O2S B2S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or more than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


    A121606E64



NG
Go to step 15
OK

CHECK EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO AND REPAIR CAUSE (FUEL INJECTOR, FUEL PRESSURE, GAS LEAK FROM SYSTEM)

9. CHECK FOR EXHAUST GAS LEAK
  1. Check for exhaust gas leak.

    OK:
    No gas leak.



NG
REPAIR OR REPLACE EXHAUST GAS LEAK POINT
OK


10. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
A240070E01
  1. Disconnect the HO2 sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Component without harness connected
    (HO2 Sensor (Bank 1))
    *2
    Component without harness connected
    (HO2 Sensor (Bank 2))



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


11. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
  1. Disconnect the B54 and B34 heated oxygen sensor connectors.

  1. Disconnect the B50 or B47 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B54-1 (HT1B) - B50-12 (HT1B)
    Always
    Below 1 Ω
    B54-3 (OX1B) - B47-2 (OX1B)
    Always
    Below 1 Ω
    B54-4 (E2) - B47-1 (EX1B)
    Always
    Below 1 Ω
    B34-1 (HT2B) - B50-13 (HT2B)
    Always
    Below 1 Ω
    B34-3 (OX2B) - B47-4 (OX2B)
    Always
    Below 1 Ω
    B34-4 (E2) - B47-3 (EX2B)
    Always
    Below 1 Ω
    B54-1 (HT1B) or B50-12 (HT1B) - Body ground
    Always
    10 kΩ or higher
    B54-3 (OX1B) or B47-2 (OX1B) - Body ground
    Always
    10 kΩ or higher
    B54-4 (E2) or B47-1 (EX1B) - Body ground
    Always
    10 kΩ or higher
    B34-1 (HT2B) or B50-13 (HT2B) - Body ground
    Always
    10 kΩ or higher
    B34-3 (OX2B) or B47-4 (OX2B) - Body ground
    Always
    10 kΩ or higher
    B34-4 (E2) or B47-3 (EX2B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12. REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor (Click here).


NEXT


13. PERFORM CONFIRMATION DRIVING PATTERN
  1. Perform the CONFIRMATION DRIVING PATTERN (P0136, P0137, P0138, P0156, P0157 and P0158).


NEXT


14. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off and wait for 30 seconds

  1. Turn the ignition switch to ON and turn the tester on.

  1. Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTC: P0136, P0137, P0138, P0156, P0157 or P0158.

  1. Check the DTC judgment result.

    Result 
    Result
    Proceed to
    ABNORMAL
    (P0136, P0137, P0138, P0156, P0157 or P0158 detected)
    A
    NORMAL
    (No DTC output)
    B



B
END
A

REPLACE AIR FUEL RATIO SENSOR (Click here)

15. REPLACE AIR FUEL RATIO SENSOR
  1. Replace the air fuel ratio sensor (Click here).


NEXT


16. PERFORM CONFIRMATION DRIVING PATTERN
  1. Perform the CONFIRMATION DRIVING PATTERN (P0136, P0137, P0138, P0156, P0157 and P0158).


NEXT


17. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off and wait for 30 seconds

  1. Turn the ignition switch to ON and turn the tester on.

  1. Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTC: P0136, P0137, P0138, P0156, P0157 or P0158.

  1. Check the DTC judgment result.

    Result 
    Result
    Proceed to
    ABNORMAL
    (P0136, P0137, P0138, P0156, P0157 or P0158 detected)
    A
    NORMAL
    (No DTC output)
    B



B
END
A

REPLACE HEATED OXYGEN SENSOR (Click here)


← P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2) (+ 5 more codes) (Aug 2009 – Jul 2014)P0137 Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2) (+ P0157) (Jul 2007 – Nov 2007) →