Home › COMMUNICATION SYSTEM › CAN COMMUNICATION › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > CAN Bus Line

for Preparation Click here


DESCRIPTION

Measure the resistance from the DLC3 before checking the CAN bus lines to troubleshoot the CAN communication system.

WIRING DIAGRAM


C107865E01


INSPECTION PROCEDURE

1.CHECK CAN BUS LINE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT)


    G026206E20
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Value
    Result
    H23-6 (CANH) - H23-14 (CANL)
    IG switch OFF
    54 to 69 Ω
    OK
    H23-6 (CANH) - H23-14 (CANL)
    IG switch OFF
    69 Ω or higher
    NG - A
    H23-6 (CANH) - H23-14 (CANL)
    IG switch OFF
    Below 54 Ω
    NG - B

    HINT:
    1. NG-A: Open in CAN Main Bus Line (Click here)
    2. NG-B: Short in CAN Bus Lines (Click here)



NG-A
OPEN IN CAN MAIN BUS LINE

NG-B
SHORT IN CAN BUS LINES
OK


2.CHECK CAN BUS LINE FOR SHORT TO B+


    G026206E22
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Value
    H23-6 (CANH) - H23-16 (BAT)
    IG switch OFF
    1 MΩ or higher
    H23-14 (CANL) -
    H23-16 (BAT)
    IG switch OFF
    1 MΩ or higher

    HINT:
    NG: Short to B+ in CAN Bus Line (Click here)



NG
SHORT TO B+ IN CAN BUS LINE
OK


3.CHECK CAN BUS LINE FOR SHORT TO GND


    G026206E23
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Value
    H23-4 (CG) - H23-6 (CANH)
    IG switch OFF
    3 kΩ or higher
    H23-4 (CG) - H23-14 (CANL)
    IG switch OFF
    3 kΩ or higher

    HINT:
    1. OK: HOW TO PROCEED WITH TROUBLESHOOTING (Click here)
    2. NG: Short to GND in CAN Bus Line (Click here)



NG
SHORT TO GND IN CAN BUS LINE
OK