CAN COMMUNICATION SYSTEM > CAN Bus Line |

| 1.CHECK CAN BUS LINE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value | Result |
| H23-6 (CANH) - H23-14 (CANL) | IG switch OFF | 54 to 69 Ω | OK |
| H23-6 (CANH) - H23-14 (CANL) | IG switch OFF | 69 Ω or higher | NG - A |
| H23-6 (CANH) - H23-14 (CANL) | IG switch OFF | Below 54 Ω | NG - B |
|
| ||||
|
| ||||
| OK | |
| 2.CHECK CAN BUS LINE FOR SHORT TO B+ |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value |
| H23-6 (CANH) - H23-16 (BAT) | IG switch OFF | 1 MΩ or higher |
| H23-14 (CANL) - H23-16 (BAT) | IG switch OFF | 1 MΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CAN BUS LINE FOR SHORT TO GND |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value |
| H23-4 (CG) - H23-6 (CANH) | IG switch OFF | 3 kΩ or higher |
| H23-4 (CG) - H23-14 (CANL) | IG switch OFF | 3 kΩ or higher |
|
| ||||
| OK | ||
| ||