Fuel Pump Control Circuit
Circuit diagnosis · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
Refer to DTC P0230 (Click here).WIRING DIAGRAM
Refer to DTC P0230 (Click here).INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK FUEL PUMP OPERATION |
 |
Check the fuel pump operation (Click here).
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 2. INSPECT TERMINAL VOLTAGE (FUEL PMP RELAY TERMINAL) |
 |
- Remove the FUEL PMP relay from the engine room relay block.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 2 - Body ground
|
Ignition switch on (IG)
|
11 to 14 V
|
FUEL PMP relay terminal 3 - Body ground
|
Ignition switch on (IG)
|
11 to 14 V
|
Text in Illustration
*a
|
Engine Room Relay Block
|
Reinstall the FUEL PMP relay.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PMP RELAY - C/OPN RELAY) |
|
|
| OK |
|
 |
|
| 3. INSPECT FUEL PUMP RELAY |
 |
- Remove the FUEL PMP relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 4
|
No battery voltage applied across terminals 1 and 2
|
Below 1 Ω
|
3 - 4
|
Battery voltage applied across terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
No battery voltage applied across terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Battery voltage applied across terminals 1 and 2
|
Below 1 Ω
|
Reinstall the FUEL PMP relay.
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 4. INSPECT FUEL PUMP RESISTOR |
 |
Inspect the fuel pump resistor (Click here).
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 5. CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR) |
 |
Remove the FUEL PMP relay from the engine room relay block.
Disconnect the fuel pump resistor connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 5 - A35-1
|
Always
|
Below 1 Ω
|
FUEL PMP relay terminal 4 - A35-2
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 5 or A35-1 - Body ground
|
Always
|
10 kΩ or higher
|
FUEL PMP relay terminal 4 or A35-2 - Body ground
|
Always
|
10 kΩ or higher
|
Reinstall the FUEL PMP relay.
Reconnect the fuel pump resistor connector.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR) |
|
|
| OK |
|
 |
|
| 6. CHECK HARNESS AND CONNECTOR (FUEL PUMP - FUEL PMP RELAY) |
 |
Remove the FUEL PMP relay from the engine room relay block.
Disconnect the fuel pump connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 4 - O9-4
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 4 or O9-4 - Body ground
|
Always
|
10 kΩ or higher
|
Reconnect the fuel pump connector.
Reinstall the FUEL PMP relay.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PUMP - FUEL PMP RELAY) |
|
|
| OK |
|
 |
|
| 7. CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - ECM) |
 |
Remove the FUEL PMP relay from the engine room relay block.
Disconnect ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 1 - D55-8 (FPR)
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
FUEL PMP relay terminal 1 or D55-8 (FPR) - Body ground
|
Always
|
10 kΩ or higher
|
Reconnect the ECM connector.
Reinstall the FUEL PMP relay.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PMP RELAY - ECM) |
|
|
| OK |
|
 |
|
| PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
|
|
| 8. INSPECT FUEL PUMP |
 |
Inspect the fuel pump (Click here).
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 9. CHECK HARNESS AND CONNECTOR (FUEL PUMP - FUEL PMP RELAY) |
 |
Disconnect the fuel pump connector.
Remove the FUEL PMP relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
O9-4 - FUEL PMP relay terminal 4
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
O9-4 or FUEL PMP relay terminal 4 - Body ground
|
Always
|
10 kΩ or higher
|
Reinstall the FUEL PMP relay.
Reconnect the fuel pump connector.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PUMP - FUEL PMP RELAY) |
|
|
| OK |
|
 |
|
| 10. INSPECT ENGINE ROOM RELAY BLOCK (C/OPN RELAY - FUEL PMP RELAY) |
 |
Remove the engine room junction block assembly from the engine room relay block.
Disconnect the engine room junction block assembly connector.
Remove the FUEL PMP relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
2E-13 - FUEL PMP relay terminal 2
|
Always
|
Below 1 Ω
|
2E-13 - FUEL PMP relay terminal 3
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
2E-13 or FUEL PMP relay terminal 2 - Body ground
|
Always
|
10 kΩ or higher
|
2E-13 or FUEL PMP relay terminal 3- Body ground
|
Always
|
10 kΩ or higher
|
Reconnect the engine room junction block assembly connector.
Reinstall the engine room junction block assembly.
Reinstall the FUEL PMP relay.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (C/OPN RELAY - FUEL PMP RELAY) |
|
|
| OK |
|
 |
|
| 11. CHECK HARNESS AND CONNECTOR (FUEL PUMP - BODY GROUND) |
 |
Disconnect the fuel pump connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
O9-5 - Body ground
|
Always
|
Below 1 Ω
|
Reconnect the fuel pump connector.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (FUEL PUMP - BODY GROUND) |
|
|
| OK |
|
 |
|
| 12. INSPECT ENGINE ROOM JUNCTION BLOCK ASSEMBLY |
 |
Inspect the engine room junction block assembly (Click here).
|
NG |
 |
|
| REPLACE ENGINE ROOM JUNCTION BLOCK ASSEMBLY (Click here)
|
|
|
| OK |
|
 |
|
| 13. CHECK HARNESS AND CONNECTOR (C/OPN RELAY - IG2 RELAY) |
 |
Remove the engine room junction block assembly from the engine room relay block.
Disconnect the engine room junction block assembly connector.
Remove the IG2 relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
2E-8 - IG2 relay terminal 3
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
2E-8 or IG2 relay terminal 3 - Body ground
|
Always
|
10 kΩ or higher
|
Reconnect the engine room junction block assembly connector.
Reinstall the engine room junction block assembly.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (C/OPN RELAY - IG2 RELAY) |
|
|
| OK |
|
 |
|
| 14. CHECK HARNESS AND CONNECTOR (C/OPN RELAY - ECM) |
 |
Remove the engine room junction block assembly from the engine room relay block.
Disconnect the engine room junction block assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
2D-12 - D56-3 (FC)
|
Always
|
Below 1 Ω
|
- Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
2D-12 or D56-3 (FC) - Body ground
|
Always
|
10 kΩ or higher
|
Reconnect the ECM connector.
Reconnect the engine room junction block assembly connector.
Reinstall the engine room junction block assembly.
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR (C/OPN RELAY - ECM) |
|
|
| OK |
|
 |
|
|