DTC P0A08-264 DC / DC Converter Status Circuit |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A08 | 264 | DC/DC converter malfunction |
|

| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A08-264 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A05-776 | Motor Electronics Coolant Pump Control Circuit / Open |
| P0A93-346, 347 | Inverter Cooling System Performance |
| P0A94-547, 548, 549 | DC / DC Converter Performance |
| P0AA6-526, 613, 655 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P3004-131, 803 | Power Cable Malfunction |
|
| ||||
| A | |
| 2.CHECK RELAY BLOCK ASSEMBLY |
![]() |
Check the condition of the fusible links (ALT and MAIN) and fuse (DC/DC-S) in the relay block. Check if the circuits are open.
|
| ||||
| OK | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |
![]() |
Check the connections of the hybrid vehicle control ECU connectors.
|
| ||||
| OK | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 5.CHECK INSULATION RESISTANCE OF HIGH-VOLTAGE SYSTEM |
Check that the service plug grip is not installed.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MG2 U - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| MG2 V - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| MG2 W - Body ground and shield ground | Power switch off | 1 MΩ or higher |
|
| ||||
| OK | |
| 6.CHECK CONNECTION CONDITION (AMD TERMINAL) |
Check that the service plug grip is not installed.
![]() ![]() |
Remove the three-phase AC cable for MGR from the inverter with converter assembly.
Check the connection of the AMD terminal.
|
| ||||
| OK | |
| 7.CHECK TERMINAL VOLTAGE (AMD TERMINAL) |
Turn the power switch off.
Check that the service plug grip is not installed.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| AMD terminal (Inverter with converter assembly side) - Body ground | Power switch off | 11 to 14 V |
|
| ||||
| OK | |
| 8.CHECK INVERTER WITH CONVERTER ASSEMBLY (MG ECU) |
Check that the service plug grip is not installed.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-7 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A42-4 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
| A42-35 (SI) - Body ground | Power switch on (IG) | 11 to 14 V |
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE HYBRID VEHICLE CONTROL ECU) |
Turn the power switch off.
Disconnect the A42 connector from the MG ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-33 (NODD) - Body ground | Power switch off | 120 to 140 kΩ |
|
| ||||
| OK | |
| 10.INSPECT INVERTER WITH CONVERTER ASSEMBLY (OPERATION OF DC/DC CONVERTER) |
![]() |
Connect the AC/DC 400 A probe to the positive auxiliary battery line.
Install the inverter cover (Click here).
Install the service plug grip.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
![]() |
Measure the current flowing from the auxiliary battery with the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
Measure the auxiliary battery voltage according to the previous conditions with the lights, blower motor and rear window defogger turned on.
| Item | Condition | Specified Condition |
| Current flowing from auxiliary battery | The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on. | 0 A or less (no current from auxiliary battery) |
| Auxiliary battery voltage | The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on. | 13 to 15 V |
|
| ||||
| OK | |
| 11.CHECK QUANTITY OF HV COOLANT |
![]() |
Check the coolant level in the inverter reserve tank.
Check for coolant leaks.
| Result | Proceed to |
| Coolant leaks are not evident. A sufficient amount of coolant remains in the inverter reserve tank. | A |
| Coolant leaks are not evident. No coolant remains in the inverter reserve tank. | B |
| Coolant leaks are evident | C |
|
| ||||
|
| ||||
| A | |
| 12.CHECK COOLANT HOSE |
![]() |
Check if the hoses of the cooling system are kinked or clogged.
|
| ||||
| OK | |
| 13.CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR) |
![]() |
Check the connection of the water pump with motor and bracket assembly connector.
|
| ||||
| OK | |
| 14.PERFORM ACTIVE TEST USING TECHSTREAM (WATER PUMP) |
Turn the the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" active test for at least 1 minute.
![]() |
Check that there are ripples in the coolant in the inverter reserve tank.
|
| ||||
| OK | |
| 15.PERFORM ACTIVE TEST USING TECHSTREAM (COOLING FAN) |
Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" active test.
|
| ||||
| OK | ||
| ||
| 16.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2 AND MG1) |
Check that the service plug grip is not installed.

Disconnect the three-phase AC cables for the hybrid vehicle transaxle assembly (MG2 and MG1) from the inverter with converter assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MG2 U terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 V terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 W terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG1 U terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG1 V terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG1 W terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
|
| ||||
| OK | |
| 17.INSPECT REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY |
![]() |
Check that the service plug grip is not installed.
Disconnect the three-phase AC cable for MGR from the inverter with converter assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MGR U terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| MGR V terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| MGR W terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 18.CHECK AMD TERMINAL |
![]() |
Check for arc marks on the AMD terminals (inverter with converter assembly side and wire harness side).
|
| ||||
| OK | ||
| ||
| 19.CHECK TERMINAL VOLTAGE (AMD TERMINAL) |
![]() |
Turn the power switch off.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| AMD terminal - Body ground | Power switch off | 11 to 14 V |
|
| ||||
| OK | ||
| ||
| 20.INSPECT HYBRID VEHICLE CONTROL ECU |
![]() |
Disconnect all hybrid vehicle control ECU connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A43-11 (NODD) - B3-5 (E1) | Power switch off | 120 to 140 kΩ |
|
| ||||
| OK | ||
| ||
| 21.INSPECT REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY |
Check that the service plug grip is not installed.
![]() |
Disconnect the No. 3 frame wire (three-phase AC cable for MGR) from the rear traction motor with transaxle assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MGR U terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| MGR V terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| MGR W terminal - Body ground and shield ground | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 22.CHECK FUSE (INV-W/P) |
![]() |
Check if there is an open circuit in the fuse (INV-W/P) in the No. 2 engine room relay block.
|
| ||||
| OK | |
| 23.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - WATER PUMP) |
![]() |
Turn the power switch off.
Disconnect the D35 connector from the hybrid vehicle control ECU.
Disconnect the A52 water pump with motor and bracket assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D35-29 (NIWP) - A52-1 (NWP) | Power switch off | Below 1 Ω |
| D35-23 (IWP) - A52-2 (SWP) | Power switch off | Below 1 Ω |
| A52-3 (GND) - Body ground | Power switch off | Below 1 Ω |
| INV-W/P fuse terminal 2 - A52-4 (+BWP) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D35-29 (NIWP) or A52-1 (NWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| D35-23 (IWP) or A52-2 (SWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| INV-W/P fuse terminal 2 or - A52-4 (+BWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||