Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A94-553    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

Refer to the description of the boost converter .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
553
Boost converter fail (FCV) signal detection (boost converter overheating)
  1. Wire harness or connector
  2. Inverter cooling system
  3. Water pump with motor and bracket assembly
  4. Hybrid vehicle transaxle assembly
  5. Rear traction motor with transaxle assembly
  6. Inverter with converter assembly (MG ECU)
  7. Cooling fan system
  8. INV-W/P fuse

MONITOR DESCRIPTION

If the boost converter (inverter with converter assembly) detects an overvoltage, it will transmit a boost converter overvoltage signal to the MG ECU. The MG ECU will send information about the malfunction to the hybrid vehicle control ECU. Upon receiving this information, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A94 (INF 553): FCV detection over heat
Required sensors / components
Boost converter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property

TYPICAL MALFUNCTION THRESHOLDS


Boost converter
Overheated

COMPONENT OPERATING RANGE


Boost converter
DTC P0A94 (INF 553) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-553 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A05-776
    Motor Electronics Coolant Pump Control Circuit / Open
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A2B-248, 250
    Drive Motor "A" Temperature Sensor Circuit Range / Performance
    P0A2C-247
    Drive Motor "A" Temperature Sensor Circuit Low
    P0A2D-249
    Drive Motor "A" Temperature Sensor Circuit High
    P0A37-258, 260
    Generator Temperature Sensor Circuit Range / Performance
    P0A38-257
    Generator Temperature Sensor Circuit Low
    P0A39-259
    Generator Temperature Sensor Circuit High
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78 (all INF codes) *1
    Drive Motor "A" Inverter Performance
    P0A79 (all INF codes) *1
    Drive Motor "B" Inverter Performance
    P0A7A (all INF codes) *1
    Generator Inverter Performance
    P0A90-251, 509
    Drive Motor "A" Performance
    P0A92-261, 521
    Hybrid Generator Performance
    P0A93-346, 347
    Inverter Cooling System Performance
    P0A94-442, 545, 546, 547, 548, 549, 550, 551, 552, 554, 555, 556, 557, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE6-225
    Hybrid Battery Positive Contactor Circuit Stuck Open
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P0AEE-276, 277
    Motor Inverter Temperature Sensor "A" Circuit Range / Performance
    P0AEF-275
    Drive Motor Inverter Temperature Sensor "A" Circuit Low
    P0AF0-274
    Drive Motor Inverter Temperature Sensor "A" Circuit High
    P0AF3-675, 676
    Sensor of Rear Motor Inverter Temperature
    P0AF4-673
    Open or Short to GND in Rear Motor Inverter Temperature Sensor
    P0AF5-674
    Short to B+ in Rear Motor Inverter Temperature Sensor
    P3004 (all INF codes) *1
    Power Cable Malfunction
    P3221-314, 315
    Generator Inverter Temperature Sensor Circuit Range / Performance
    P3226-562, 563
    Power Cable Malfunction
    P3227-583
    Converter Temperature Sensor Circuit Low
    P3228-584
    Converter Temperature Sensor Circuit High

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A94-553 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK QUANTITY OF HV COOLANT


    A169560E01
  1. Check the coolant level in the inverter reserve tank.

  1. Check for coolant leaks.

    Result:
    Result
    Proceed to
    Coolant leaks are not evident. A sufficient amount of coolant remains in the inverter reserve tank.
    A
    Coolant leaks are not evident. No coolant remains in the inverter reserve tank.
    B
    Coolant leaks are evident
    C

    HINT:
    After repairing the coolant leaks and adding coolant, perform the "Activate the Water Pump" active test (HV ECU active test item) and the "Control the Electric Cooling Fan" active test (ENHANCED OBDII active test item) and make sure that there are no malfunctions.



B
ADD HV COOLANT

C
CHECK FOR COOLANT LEAKS AND ADD COOLANT
A


3.CHECK COOLANT HOSE


    A105138E03
  1. Check if the hoses of the cooling system are kinked or clogged.

    OK:
    The hoses of the cooling system are not kinked or clogged.



NG
CORRECT THE PROBLEM
OK


4.CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)


    A174885
  1. Check the connection of the water pump with motor and bracket assembly connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


5.PERFORM ACTIVE TEST USING TECHSTREAM (WATER PUMP)
  1. Turn the the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the "Activate the Water Pump" active test for at least 1 minute.



    A169560E01
  1. Check that there are ripples in the coolant in the inverter reserve tank.

    OK:
    There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed.

    NOTICE:
    In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will not operate for 20 seconds after the power switch is turned on (READY).

    HINT:
    The water pump with motor and bracket assembly will also operate in inspection mode.



NG
Go to step 21
OK


6.PERFORM ACTIVE TEST USING TECHSTREAM (COOLING FAN)
  1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

  1. Perform the "Control the Electric Cooling Fan" active test.

    OK:
    The cooling fan rotates.



NG
CHECK COOLING FAN SYSTEM (Click here)
OK


7.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    A174883E01
  1. Check the connections of all hybrid vehicle control ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


8.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


9.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Disconnect connector B49 from the MG ECU.

  1. Turn the power switch on (IG).



    A174438E04
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-23 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-21 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-20 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-19 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-18 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - B49-23 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-21 (MSN) - B49-20 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-19 (MCS) - B49-18 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) or B49-23 (MRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-21 (MSN) or B49-20 (MSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-19 (MCS) or B49-18 (MCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 15
OK


10.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Turn the power switch on (IG).



    A174438E03
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-22 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-11 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-10 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-9 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-8 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - B49-22 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-11 (GSN) - B49-10 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-9 (GCS) - B49-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-11 (GSN) or B49-10 (GSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 17
OK


11.CHECK HARNESS AND CONNECTOR (MG ECU - REAR MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Disconnect connector A42 from the MG ECU.

  1. Turn the power switch on (IG).



    A174426E05
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-22 (RRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-29 (RSN) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-30 (RSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-11 (RCS) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-23 (RCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) - A42-22 (RRFG)
    Power switch off
    7.65 to 10.2 Ω
    A42-29 (RSN) - A42-30 (RSNG)
    Power switch off
    12.6 to 16.8 Ω
    A42-11 (RCS) - A42-23 (RCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) or A42-22 (RRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A42-29 (RSN) or A42-30 (RSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A42-11 (RCS) or A42-23 (RCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 19
OK


12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


13.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)


    A174891
  1. Check the connection of the rear motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


14.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

15.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


16.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)


    A174890
  1. Disconnect the motor resolver connector.



    A174440E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-4 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B54-2 (MSN) - B54-5 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B54-3 (MCS) - B54-6 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-2 (MSN)
    Power switch off
    10 MΩ or higher
    B54-1 (MRF) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-2 (MSN) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-5 (MSNG)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    B54-5 (MSNG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

17.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


18.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)


    A174889
  1. Disconnect the generator resolver connector.



    A174439E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-6 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B53-2 (GSN) - B53-7 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B53-3 (GCS) - B53-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-2 (GSN)
    Power switch off
    10 MΩ or higher
    B53-1 (GRF) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-2 (GSN) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-7 (GSNG)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    B53-7 (GSNG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

19.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)


    A174891
  1. Check the connection of the rear motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


20.CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (REAR MOTOR RESOLVER)


    A174891
  1. Disconnect the rear motor resolver connector.



    A174440E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    j7-1 (RRF) - j7-4 (RRFG)
    Power switch off
    7.65 to 10.2 Ω
    j7-2 (RSN) - j7-5 (RSNG)
    Power switch off
    12.6 to 16.8 Ω
    j7-3 (RCS) - j7-6 (RCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    j7-1 (RRF) - j7-2 (RSN)
    Power switch off
    10 MΩ or higher
    j7-1 (RRF) - j7-3 (RCS)
    Power switch off
    10 MΩ or higher
    j7-2 (RSN) - j7-3 (RCS)
    Power switch off
    10 MΩ or higher
    j7-4 (RRFG) - j7-5 (RSNG)
    Power switch off
    10 MΩ or higher
    j7-4 (RRFG) - j7-6 (RCSG)
    Power switch off
    10 MΩ or higher
    j7-5 (RSNG) - j7-6 (RCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

21.CHECK FUSE (INV-W/P)


    A174902E03
  1. Check if there is an open circuit in the fuse (INV-W/P) in the No. 2 engine room relay block.

    OK:
    There is no open circuit in the fuse (INV-W/P).

    HINT:
    If the result is NG, replace the fuse (INV-W/P) with a new one.



NG
REPLACE FUSE (INV-W/P)
OK


22.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - WATER PUMP)


    A184421E04
  1. Turn the power switch off.

  1. Disconnect the D35 connector from the hybrid vehicle control ECU.

  1. Disconnect the A52 water pump with motor and bracket assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    D35-29 (NIWP) - A52-1 (NWP)
    Power switch off
    Below 1 Ω
    D35-23 (IWP) - A52-2 (SWP)
    Power switch off
    Below 1 Ω
    A52-3 (GND) - Body ground
    Power switch off
    Below 1 Ω
    INV-W/P fuse terminal 2 - A52-4 (+BWP)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    D35-29 (NIWP) or A52-1 (NWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    D35-23 (IWP) or A52-2 (SWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    INV-W/P fuse terminal 2 or - A52-4 (+BWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY (Click here)