2014 Hilux · Service Manual ENGINE

P0489 Exhaust Gas Recirculation Control Circuit Low

Diagnostic trouble codes · Vehicles built Jun 2011 – Jul 2012

Also covers:

Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

The EGR system recirculates exhaust gases, in order to suit every driving condition. The recirculated gas mingles with intake air, therefore the EGR system can slow combustion speed and keep the combustion temperature down. This helps reduce NOx emission.
In order to increase EGR circulation efficiency, the ECM adjusts the lift amount of the EGR valve and throttle valve angle.
DTC No.
DTC Detection Condition
Trouble Area
P0489
Open or short in E-VRV circuit for 5 seconds or more
(1 trip detection logic)
  1. E-VRV
  2. Open or short in E-VRV circuit
  3. ECM
P0490
Open or short in E-VRV circuit for 5 seconds or more
(1 trip detection logic)
  1. E-VRV
  2. Open or short in E-VRV circuit
  3. ECM

WIRING DIAGRAM

A154731E04

INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).


1. INSPECT VACUUM REGULATING VALVE (E-VRV)
  1. Inspect the vacuum regulating valve (E-VRV) (Click here).



NG
REPLACE VACUUM REGULATING VALVE (E-VRV) (Click here)
OK


2. INSPECT VACUUM REGULATING VALVE (E-VRV) (POWER SOURCE VOLTAGE)

  1. A199385E01
    Disconnect the V1 vacuum regulating valve (E-VRV) connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the wire harness side connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    V1-1 - Body ground
    11 to 14 V



NG
Go to step 4
OK


3. CHECK HARNESS AND CONNECTOR (VACUUM REGULATING VALVE (E-VRV) - ECM)

  1. A201250E01
    Disconnect the V1 vacuum regulating valve (E-VRV) connector.

  1. Disconnect the E7 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    V1-2 - EGR (E7-9)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    V1-2 or EGR (E7-9) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM (Click here)

4. CHECK HARNESS AND CONNECTOR (VACUUM REGULATING VALVE (E-VRV) - INTEGRATION RELAY)
A201249E01
  1. Remove the integration relay from the engine room junction block (Click here).

  1. Disconnect the 1J integration relay connector.

  1. Disconnect the V1 vacuum regulating valve (E-VRV) connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    1J-5 - V1-1
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    1J-5 - V1-1
    Below 1 Ω
    1J-5 or V1-1 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

INSPECT ECM POWER SOURCE CIRCUIT (Click here)