Washer Fluid Level Warning Switch Circuit
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
When the volume of washer fluid decreases to below a certain level (when the level warning switch assembly is turned on), the multi-information display warns the driver by displaying a message*1 or the combination meter assembly warns the driver by displaying a washer fluid warning light*2.- *1: w/ Multi-information Display
- *2: w/o Multi-information Display
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (WASHER SWITCH) |
Use the Data List to check if the level warning switch assembly is functioning properly (Click here).
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Washer Switch
Level warning switch / ON or OFF
ON: Fluid volume is less than 550 to 750 cc (33.5 to 45.7 cu.in.)
OFF: Fluid volume is more than 550 to 750 cc (33.5 to 45.7 cu.in.)
-
- OK:
- On intelligent tester screen, item changes between ON and OFF according to above chart.
|
|
||||
| OK | ||
| ||
| 2. INSPECT LEVEL WARNING SWITCH ASSEMBLY |
Remove the level warning switch assembly (Click here).
Inspect the level warning switch assembly (Click here)
|
|
||||
| OK | |
| 3. INSPECT WASHER WIRING ASSEMBLY |
Disconnect the A23 and B washer wiring assembly connectors.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A23-3 (S) - B-1
Always
Below 1 Ω
A23-6 (E) - B-2
Always
Below 1 Ω
A23-3 (S) or B-1 - Body ground
Always
10 kΩ or higher
A23-6 (E) or B-2 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (WASHER WIRING ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND) |
Disconnect the A23 washer wiring assembly connector.
Disconnect the G7 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A23-3 (S) - G7-20 (WLVL)
Always
Below 1 Ω
A23-6 (E) - Body ground
Always
Below 1 Ω
A23-3 (S) or G7-20 (WLVL) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||