Home › Power Source / Network › 3UR-FE (BATTERY / CHARGING) › GENERATOR › from 2015.08
RM2660E _57 Power Source / Network _052834 3UR-FE BATTERY / CHARGING _0255525 GENERATOR A

3UR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 53806 6.REMOVE FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY LH

Hide 53805 7.REMOVE FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY RH

Hide 51405A 8.REMOVE NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY

Hide 53736G 10.REMOVE FRONT FENDER APRON SEAL FRONT RH

Hide 44310 11.DISCONNECT VANE PUMP ASSEMBLY

Hide 27020 13.REMOVE GENERATOR ASSEMBLY

a.
A177892

Disconnect the generator connector.


b.

Open the terminal cap.


c.

Remove the nut and disconnect the generator wire.


d.

Remove the bolt and disconnect the wire harness bracket from the generator.


e.
A177893

Remove the 3 bolts, nut and generator.


f.

Remove the stud bolt.