Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052841 METER / GAUGE / DISPLAY _0255598 METER / GAUGE SYSTEM C

METER / GAUGE / DISPLAY  METER / GAUGE SYSTEM  B1501  Sub Fuel Sender Open Detected  


DESCRIPTION

HINT:

Trouble code B1501 is only output for double tank equipped vehicles


This DTC is stored when the combination meter detects a fuel sender gauge malfunction via the CAN.

DTC Code DTC Detection Condition Trouble Area
B1501 When the combination meter detects a fuel sender gauge malfunction.
·

Harness or connector

·

Combination meter assembly

·

Fuel sender gauge assembly



WIRING DIAGRAM

E156822E04
1.87,1.858 3.762,2.041 1.892,0.184 10 Fuel Sender Gauge Assembly 3.92,0.783 4.127,0.920 0.207,0.137 10 E8 3.916,1.308 4.130,1.452 0.214,0.144 10 E8 3.916,2.33 4.130,2.474 0.214,0.144 10 E7 4.995,1.672 5.383,1.837 0.387,0.165 10 FUEL 3.206,1.211 3.334,1.367 0.128,0.156 10 S 2.45,1.211 2.564,1.367 0.114,0.156 10 E 3.933,1.139 4.122,1.291 0.188,0.151 10 10 3.933,0.615 4.112,0.766 0.179,0.151 10 22 3.925,2.169 4.113,2.321 0.188,0.151 10 15 3.854,2.995 5.718,3.169 1.864,0.174 10 Combination Meter Assembly 1.87,1.697 2.098,1.850 0.228,0.154 10 M2 4.212,1.22 4.341,1.385 0.128,0.165 10 L 4.212,0.69 4.415,0.850 0.202,0.161 10 FE 4.212,2.248 4.461,2.423 0.248,0.174 10 ET 3.374,1.216 3.474,1.367 0.100,0.151 10 3 2.29,1.216 2.390,1.367 0.100,0.151 10 1

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (FUEL SENDER GAUGE)
Combination Meter
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Fuel Input Fuel sender gauge (main) input signal/Min.: 0, Max.: 127.5 Fuel sender input value Unit: L

a.

Operate the intelligent tester according to the display and select the Data List (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST).

OK:

Fuel value displayed on the intelligent tester is almost same as needle indication.


Result
Result Proceed to
NG A
OK (w/ Multi-information Display) B
OK (w/o Multi-information Display) C



A

2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE AND BODY GROUND)

B

C

2.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE AND BODY GROUND)
U166217E02
1.24,1.729 1,2.208 false 1.25,1.813 1.719,2.188 false 3.75,1.823 3.875,2.188 false 5.583,1.594 5.396,2.208 false 6.083,1.583 6.313,2.229 false 0.552,1.594 0.75,1.75 0.198,0.156 10 false E8 2.396,1.594 2.594,1.75 0.198,0.156 10 false E7 0.896,2.229 1,2.385 0.104,0.156 10 false L 1.729,2.229 1.948,2.375 0.219,0.146 10 false FE 3.854,2.229 4.063,2.385 0.208,0.156 10 false ET 4.75,1.594 4.958,1.75 0.208,0.156 10 false M2 6.333,2.26 6.448,2.406 0.115,0.146 10 false S 5.302,2.25 5.427,2.406 0.125,0.156 10 false E 1.125,0.031 3.448,0.365 2.323,0.333 10 false Rear view of wire harness connector: (to Combination Meter Assembly) 4.531,0.031 6.906,0.385 2.375,0.354 10 false Front view of wire harness connector: (to Fuel Sender Gauge Assembly)

a.

Disconnect the E7 and E8 meter connectors.


b.

Disconnect the M2 gauge connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
E8-10 (L) - M2-3 (S) Always Below 1 Ω
E8-22 (FE) - M2-1 (E)
E7-15 (ET) - Body ground
E8-10 (L) or M2-3 (S) - Body ground Always 10 kΩ or higher




OK

3.INSPECT FUEL SENDER GAUGE ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT FUEL SENDER GAUGE ASSEMBLY
E154158E01
0.507,0.068 2.455,0.397 1.948,0.330 10 Component without connected: (Fuel Sender Gauge) 0.585,3.201 0.706,3.364 0.121,0.163 10 F 0.593,4.087 0.708,4.250 0.114,0.163 10 E 1.444,3.29 0.739,3.29 false 1.375,4.167 0.748,4.167 false 0.871,1.921 0.992,2.063 0.121,0.142 10 S 2.447,1.91 2.568,2.052 0.121,0.142 10 E 1.504,1.618 1.034,1.967 false 1.934,1.618 2.404,1.967 false





e.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
3 (S) - 1 (E) Float level is F (upper) 12 to 18 Ω
Float level is E (lower) 405 to 415 Ω


Result
Result Proceed to
OK A
NG (for 1GR-FE) B
NG (for 1UR-FE) C
NG (for 3UR-FE) D
NG (for 1VD-FTV) E



A

4.CHECK COMBINATION METER ASSEMBLY

B

C

D

E

4.CHECK COMBINATION METER ASSEMBLY
a.

Check the combination meter type.


Result
Result Proceed to
w/ Multi-information Display A
w/o Multi-information Display B


A

B