Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows) › from 2015.08
RM2660E _59 Vehicle Exterior _052850 WINDOW / GLASS _0255725 POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows) J

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)  Auto Down Operation does not Fully Open Power Window (Catch Protection Function is Activated)  


DESCRIPTION

If a door glass or a power window regulator motor assembly does not operate smoothly, the catch protection function may be triggered automatically, resulting in the auto down operation being unable to fully open the window.

CAUTION / NOTICE / HINT

NOTICE:
·

If a power window regulator motor assembly has been replaced with a new one, initialize the power window control system (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION).

·

If a power window regulator motor assembly and door window regulator sub-assembly have been removed and installed, or if a power window regulator motor assembly was reused when a door glass or door glass run was replaced, initialize the power window control system (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION).



HINT:

This symptom may occur for any of the windows.


PROCEDURE

1.PERFORM INITIALIZATION (APPLICABLE LOCATION)
a.

Initialize the power window regulator motor assembly (applicable location) (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION).



NEXT

2.CHECK POWER WINDOW CONTROL SYSTEM AUTO UP / DOWN FUNCTION [APPLICABLE LOCATION]
2.CHECK POWER WINDOW CONTROL SYSTEM AUTO UP / DOWN FUNCTION [APPLICABLE LOCATION]
a.

Check that each power window moves when the auto up and down function of the multiplex network master switch assembly, power window regulator switch assembly, rear power window regulator switch assembly LH or rear power window regulator switch assembly RH is operated (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>OPERATION CHECK).

OK:

Auto up and down function is normal (applicable location).




OK

END (PROBLEM DUE TO INITIALIZATION FAILURE)

NG

3.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)
3.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)
a.

Remove the door window regulator.



b.

Install the window glass to the door glass run.



c.

Check if the door window regulator operates smoothly.


d.

Check that the window glass slides smoothly when sliding it down by hand.

NOTICE:

Perform initialization again (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION).


HINT:

Ensure the following:

·

The window glass fits with the glass run without improper contact or deformation.

·

Foreign matter is not caught in the glass run.

·

The glass run is not misaligned.

·

The belt moulding or inner weatherstrip is not caught.

·

The glass is not tilted and does not catch.



OK:

Door window glass slides smoothly.


Result
Result Proceed to
OK (Driver door power window) A
OK (Front passenger door power window) B
OK (Rear door LH power window) C
OK (Rear door RH power window) D
NG E



A

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

B

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

C

REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

D

REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

E

FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN MATTER CAUSING IMPROPER FIT OR REPLACE)