The Variable Valve Timing (VVT) system adjusts the intake valve timing to improve driveability. The engine oil pressure turns the VVT controller to adjust the valve timing.
The cam timing oil control solenoid assembly (for intake camshaft) operates according to signals received from the ECM to control the position of the camshaft timing oil control valve assembly and supply engine oil. The camshaft timing oil control valve assembly moves when the ECM applies 12 V to the cam timing oil control solenoid assembly (for intake camshaft). The ECM changes the energizing time of the cam timing oil control solenoid assembly (for intake camshaft) duty-cycle in accordance with the camshaft position, crankshaft position, throttle position, etc.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Note |
|---|---|---|---|---|---|
| P001013 | A Camshaft Position Actuator Bank 1 Circuit Open | Open or short in cam timing oil control solenoid assembly (for intake camshaft of bank 1) circuit (1 trip detection logic). |
·
Open or short in cam timing oil control solenoid assembly (for intake camshaft of bank 1) circuit
·
Cam timing oil control solenoid assembly (for intake camshaft of bank 1)
·
ECM |
Comes on | SAE: P0010 |
| P002013 | Camshaft Position "A" Actuator Bank 2 Circuit Open | Open or short in cam timing oil control solenoid assembly (for intake camshaft of bank 2) circuit (1 trip detection logic). |
·
Open or short in cam timing oil control solenoid assembly (for intake camshaft of bank 2) circuit
·
Cam timing oil control solenoid assembly (for intake camshaft of bank 2)
·
ECM |
Comes on | SAE: P0020 |
This DTC is designed to detect an open or short in the cam timing oil control solenoid assembly (for intake camshaft) circuit. If the cam timing oil control solenoid duty-cycle is excessively high or low while the ignition switch is ON or the engine is running, the ECM will illuminate the MIL and store this DTC.
| Required Sensors/Components | Cam timing oil control solenoid assembly (for intake camshaft) |
| Frequency of Operation | Continuous |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Start the engine [A].
Wait 5 seconds or more [B].
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
Read the pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
Input the DTC: P001013 or P002013.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
·
DTC judgment completed
·
System normal |
| ABNORMAL |
·
DTC judgment completed
·
System abnormal |
| INCOMPLETE |
·
DTC judgment not completed
·
Perform driving pattern after confirming DTC enabling conditions |
If the judgment result is NORMAL, the system is normal.
If the judgment result is ABNORMAL, the system has a malfunction.
If the judgment result is INCOMPLETE, perform steps [A] through [C] again.
Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
| DTC | Suspected Area |
|---|---|
| P001013 | Bank 1 |
| P002013 | Bank 2 |
Clear the DTC after recording the freeze frame data and DTC.
Turn the ignition switch off and wait for at least 30 seconds.
Start the engine.
Read the DTCs.
| Result | Proceed to |
|---|---|
| P001013 or P002013 is output | A |
| DTCs are not output | B |
A
B
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
for bank 1: Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>CAMSHAFT OIL CONTROL SOLENOID (for Bank 1)>INSPECTION
for bank 2: Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>CAMSHAFT OIL CONTROL SOLENOID (for Bank 2)>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for bank 1: Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>CAMSHAFT OIL CONTROL SOLENOID (for Bank 1)>REMOVAL
for bank 2: Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>CAMSHAFT OIL CONTROL SOLENOID (for Bank 2)>REMOVAL
Disconnect the cam timing oil control solenoid assembly (for intake camshaft) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(C15,C38,C16)Location & Routingewd_type=routing;type=c,c,c;code=C15,C38,C16 |
||
| C15-1 (+R) - C38-26 (OC1+) | Always | Below 1 Ω |
| C15-2 (-R) - C38-25 (OC1-) | Always | Below 1 Ω |
| C16-1 (+) - C38-24 (OC2+) | Always | Below 1 Ω |
| C16-2 (-) - C38-23 (OC2-) | Always | Below 1 Ω |
| C15-1 (+R) or C38-26 (OC1+) - Body ground and other terminals | Always | 10 kΩ or higher |
| C15-2 (-R) or C38-25 (OC1-) - Body ground and other terminals | Always | 10 kΩ or higher |
| C16-1 (+) or C38-24 (OC2+) - Body ground and other terminals | Always | 10 kΩ or higher |
| C16-2 (-) or C38-23 (OC2-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG