Home › Power Source / Network › F33A-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.07
RM38G0E _57 Power Source / Network _106328 F33A-FTV BATTERY / CHARGING _0489033 CHARGING SYSTEM C

F33A-FTV BATTERY / CHARGING  CHARGING SYSTEM  P065C07  Generator "A" Mechanical Performance Mechanical Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P065C07 Generator "A" Mechanical Performance Mechanical Failure All of the following conditions are met (1 trip detection logic):
·

Engine running (except during engine cranking).

·

No malfunction in the LIN communication system.

·

Alternator speed is less than 560 rpm.

·

EXC circuit is ON.


·

Fan and generator V belt

·

V-Ribbed belt tensioner assembly

·

Generator assembly wiring

·

Generator assembly


Charge warning is displayed SAE: P065C

WIRING DIAGRAM

Refer to the wiring diagram for the P062049.

Click herePower Source / Network>F33A-FTV (BATTERY / CHARGING)>CHARGING SYSTEM>P062049

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK FAN AND GENERATOR V BELT

OK

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

NG

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

OK

3.CHECK GENERATOR ASSEMBLY WIRING

NG

REPLACE V-RIBBED BELT TENSIONER ASSEMBLY

3.CHECK GENERATOR ASSEMBLY WIRING

OK

4.CHECK FOR ABNORMAL NOISE

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY WIRING

4.CHECK FOR ABNORMAL NOISE

OK

5.CHARGING CIRCUIT WITHOUT LOAD

NG

5.CHARGING CIRCUIT WITHOUT LOAD

OK

6.CHARGING CIRCUIT WITH LOAD

NG