When the brake pedal is depressed, the stop light switch assembly outputs a signal to the ECM. The ECM uses this signal to control cancellation of vehicle speed by the cruise control. When the ECM determines that terminals STP and ST1- of the stop light switch assembly are both less than 1 V, DTC P057162 is stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| P057162 | Brake Switch "A" Signal Compare Failure | When the ignition switch is ON and the cruise control system is operating, the ECM detects that the voltage at terminal STP and ST1- are both less than 1 V for 0.5 seconds or more. |
·
Harness or connector
·
Stop light switch assembly
·
ECM |
Cruise Control | A |
for 1GR-FE
for V35A-FTS
for F33A-FTV
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the ECM, refer to Service Bulletin.
Pre-procedure1
Disconnect the B43 stop light switch assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B43)Location & Routingewd_type=routing;type=c;code=B43 Click Connector(B43)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Stop Light Switch Assemblyewd_type=component;type=c;code=B43;pinno=2 |
||
| B43-2 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B43)Location & Routingewd_type=routing;type=c;code=B43 Click Connector(B43)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Stop Light Switch Assemblyewd_type=component;type=c;code=B43;pinno=6,7 |
||
| B43-6 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| B43-6 (B) - Body ground | Ignition switch off | Below 1 V |
| B43-7 (B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Click hereVehicle Exterior>LIGHTING (EXT)>STOP LIGHT SWITCH>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check vehicle condition.
| Result | Proceed to |
|---|---|
| for 1GR-FE | A |
| for V35A-FTS | B |
| for F33A-FTV | C |
A
B
C
Pre-procedure1
Disconnect the B2 ECM connectors.
Disconnect the B43 stop light switch assembly connector.
Disconnect the B20 No. 2 skid control ECU (brake actuator assembly) connector.
Disconnect the I40 certification ECU (smart key ECU assembly) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B2,B43)Location & Routingewd_type=routing;type=c,c;code=B2,B43 Click Connector(B43)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Stop Light Switch Assemblyewd_type=component;type=c;code=B43;pinno=3,5 |
||
| B2-7 (STP) - B43-3 (L) | Always | Below 1 Ω |
| B2-8 (ST1-) - B43-5 (L) | Always | Below 1 Ω |
| B2-7 (STP) or B43-3 (L) - Body ground | Always | 10 kΩ or higher |
| B2-8 (ST1-) or B43-5 (L) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the B1 ECM connectors.
Disconnect the B43 stop light switch assembly connector.
Disconnect the B20 No. 2 skid control ECU (brake actuator assembly) connector.
Disconnect the I40 certification ECU (smart key ECU assembly) connector.
Disconnect the C36 TCM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B1,B43)Location & Routingewd_type=routing;type=c,c;code=B1,B43 Click Connector(B43)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Stop Light Switch Assemblyewd_type=component;type=c;code=B43;pinno=5,3 |
||
| B1-21 (ST1-) - B43-5 (L) | Always | Below 1 Ω |
| B1-22 (STP) - B43-3 (L) | Always | Below 1 Ω |
| B1-21 (ST1-) or B43-5 (L) - Body ground | Always | 10 kΩ or higher |
| B1-22 (STP) or B43-3 (L) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the B70 ECM connectors.
Disconnect the B43 stop light switch assembly connector.
Disconnect the B20 No. 2 skid control ECU (brake actuator assembly) connector.
Disconnect the I40 certification ECU (smart key ECU assembly) connector.
Disconnect the C36 TCM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B70,B43)Location & Routingewd_type=routing;type=c,c;code=B70,B43 Click Connector(B43)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Stop Light Switch Assemblyewd_type=component;type=c;code=B43;pinno=5,3 |
||
| B70-21 (ST1-) - B43-5 (L) | Always | Below 1 Ω |
| B70-22 (STP) - B43-3 (L) | Always | Below 1 Ω |
| B70-21 (ST1-) or B43-5 (L) - Body ground | Always | 10 kΩ or higher |
| B70-22 (STP) or B43-3 (L) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG