All the doors except the luggage compartment door have the double lock function. This system is set and unset by the main body ECU. When the main body ECU sends a request signal to each door ECU to set or unset the double lock function, the double lock motor built into each door lock operates.
The power door lock control system uses the CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting. Troubleshoot the power door lock control system after confirming that the communication systems are functioning properly.
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.
Check that the doors can be locked and unlocked normally using the wireless operation.
Click hereVehicle Interior>DOOR LOCK>WIRELESS DOOR LOCK CONTROL SYSTEM>OPERATION CHECK
Doors can be locked and unlocked normally using wireless operation.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>DOOR LOCK>WIRELESS DOOR LOCK CONTROL SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Check the double lock operation.
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>OPERATION CHECK
| Result | Proceed to |
|---|---|
| All doors cannot be double-locked or double-unlocked. | A |
| Only front left door cannot be double-locked or double-unlocked. | B |
| Only front right door cannot be double-locked or double-unlocked. | C |
| Only rear left door cannot be double-locked or double-unlocked. | D |
| Only rear right door cannot be double-locked or double-unlocked. | E |
A
B
C
D
E
OK
NG
Disconnect the E21 front door with motor lock assembly LH connector.
Disconnect the E24 front multiplex network door ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(E21,E24)Location & Routingewd_type=routing;type=c,c;code=E21,E24 Click Connector(E21)Body>Front Door Wire LH / Front Door Wire RH>Front Door Lock with Motor Assembly LHewd_type=component;type=c;code=E21;pinno=4,3,6,5 Click Connector(E24)Body>Front Door Wire LH / Front Door Wire RH>Front Multiplex Network Door ECU LHewd_type=component;type=c;code=E24;pinno=5,6,24,4 |
||
| E21-4 (DL) - E24-5 (A1+) | Always | Below 1 Ω |
| E21-3 (UNDL) - E24-6 (A1-) | Always | Below 1 Ω |
| E21-6 (DLSR) - E24-24 (DBLS) | Always | Below 1 Ω |
| E21-5 (E) - E24-4 (DBE) | Always | Below 1 Ω |
| E21-4 (DL) or E24-5 (A1+) - Other terminals and body ground | Always | 10 kΩ or higher |
| E21-3 (UNDL) or E24-6 (A1-) - Other terminals and body ground | Always | 10 kΩ or higher |
| E21-6 (DLSR) or E24-24 (DBLS) - Other terminals and body ground | Always | 10 kΩ or higher |
| E21-5 (E) or E24-4 (DBE) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
OK
NG
Disconnect the E3 front door with motor lock assembly RH connector.
Disconnect the E6 front multiplex network door ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(E3,E6)Location & Routingewd_type=routing;type=c,c;code=E3,E6 Click Connector(E3)Body>Front Door Wire LH / Front Door Wire RH>Front Door Lock with Motor Assembly RHewd_type=component;type=c;code=E3;pinno=2,1,9,10 Click Connector(E6)Body>Front Door Wire LH / Front Door Wire RH>Front Multiplex Network Door ECU RHewd_type=component;type=c;code=E6;pinno=5,6,24,4 |
||
| E3-2 (DL) - E6-5 (A1+) | Always | Below 1 Ω |
| E3-1 (UNDL) - E6-6 (A1-) | Always | Below 1 Ω |
| E3-9 (DLSR) - E6-24 (DBLS) | Always | Below 1 Ω |
| E3-10 (E) - E6-4 (DBE) | Always | Below 1 Ω |
| E3-2 (DL) or E6-5 (A1+) - Other terminals and body ground | Always | 10 kΩ or higher |
| E3-1 (UNDL) or E6-6 (A1-) - Other terminals and body ground | Always | 10 kΩ or higher |
| E3-9 (DLSR) or E6-24 (DBLS) - Other terminals and body ground | Always | 10 kΩ or higher |
| E3-10 (E) or E6-4 (DBE) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
OK
NG
Disconnect the F13 rear door lock assembly LH connector.
Disconnect the F15 rear multiplex network door ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(F13,F15)Location & Routingewd_type=routing;type=c,c;code=F13,F15 Click Connector(F13)Body>No. 1 Rear Door Wire / No. 2 Rear Door Wire>Rear Door Lock with Motor Assembly LHewd_type=component;type=c;code=F13;pinno=2,1,5,6 Click Connector(F15)Body>No. 1 Rear Door Wire / No. 2 Rear Door Wire>Rear Multiplex Network Door ECU LHewd_type=component;type=c;code=F15;pinno=5,6,24,4 |
||
| F13-2 (DL) - F15-5 (A1+) | Always | Below 1 Ω |
| F13-1 (UNDL) - F15-6 (A1-) | Always | Below 1 Ω |
| F13-5 (DLSR) - F15-24 (DBLS) | Always | Below 1 Ω |
| F13-6 (E) - F15-4 (DLE1) | Always | Below 1 Ω |
| F13-2 (DL) or F15-5 (A1+) - Other terminals and body ground | Always | 10 kΩ or higher |
| F13-1 (UNDL) or F15-6 (A1-) - Other terminals and body ground | Always | 10 kΩ or higher |
| F13-5 (DLSR) or F15-24 (DBLS) - Other terminals and body ground | Always | 10 kΩ or higher |
| F13-6 (E) or F15-4 (DLE1) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
OK
NG
Disconnect the F2 rear door lock assembly RH connector.
Disconnect the F4 rear multiplex network door ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(F2,F4)Location & Routingewd_type=routing;type=c,c;code=F2,F4 Click Connector(F2)Body>No. 1 Rear Door Wire / No. 2 Rear Door Wire>Rear Door Lock with Motor Assembly RHewd_type=component;type=c;code=F2;pinno=4,3,9,10 Click Connector(F4)Body>No. 1 Rear Door Wire / No. 2 Rear Door Wire>Rear Multiplex Network Door ECU RHewd_type=component;type=c;code=F4;pinno=5,6,24,4 |
||
| F2-4 (DL) - F4-5 (A1+) | Always | Below 1 Ω |
| F2-3 (UNDL) - F4-6 (A1-) | Always | Below 1 Ω |
| F2-9 (DLSR) - F4-24 (DBLS) | Always | Below 1 Ω |
| F2-10 (E) - F4-4 (DLE1) | Always | Below 1 Ω |
| F2-4 (DL) or F4-5 (A1+) - Other terminals and body ground | Always | 10 kΩ or higher |
| F2-3 (UNDL) or F4-6 (A1-) - Other terminals and body ground | Always | 10 kΩ or higher |
| F2-9 (DLSR) or F4-24 (DBLS) - Other terminals and body ground | Always | 10 kΩ or higher |
| F2-10 (E) or F4-4 (DLE1) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG