Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0453477 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0ABF11  Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground  P0ABF15  Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open  P0B0E11  Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground  P0B0E15  Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open  P1CBB12  Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery  P1CBB14  Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open  


DESCRIPTION

A battery current sensor, which is mounted on the positive cable side of each No. 1 EV battery junction block assembly, detects the current flowing to or from the battery pack. The battery current sensor sends a voltage, which varies between 0 and 5 V in proportion to the amperage, to the IB0 terminal of the battery ECU assembly. Similarly, it sends a voltage, which varies between 0 and 5 V in inverse proportion to the amperage, to the IB1 terminal of the battery ECU assembly. When the voltage at the IB0 terminal is below 2.8 V and the voltage at the IB1 terminal is above 2.2 V, this indicates that the EV supply battery assembly is being discharged. Additionally, Meanwhile, when the voltage at of the IB0 terminal is above 2.8 V and the voltage at of the IB1 terminal is below 2.2 V, this indicates that the EV supply battery assembly is being charged. The battery ECU assembly determines the charging and discharging amount of the EV supply battery assembly based on the voltages input to the IB0 terminal and IB1 terminal and calculates the SOC of the EV supply battery assembly through the accumulated amperage.

A378924E06
0.229,0.615 0.969,1.073 0.74,0.458 10 false Current 0.229,0.438 0.969,0.896 0.74,0.458 10 false Charging 1.281,1.313 2.979,1.615 1.698,0.302 10 false Battery Current sensor 2.208,1.729 2.813,2.135 0.604,0.406 10 false VIB 2.208,1.938 2.813,2.344 0.604,0.406 10 false IB0 2.198,2.25 2.802,2.656 0.604,0.406 10 false GIB 2.219,2.094 2.823,2.5 0.604,0.406 10 false IB1 1.854,2.885 3.563,3.719 1.708,0.833 10 false Battery ECU Assembly 3.198,3.188 4.063,3.531 0.865,0.344 10 false Charging 4.219,3.49 5.813,3.74 1.594,0.25 10 false EV Battery Current (A) 5.156,2.521 5.667,2.76 0.51,0.24 10 false IB0 5.917,1.823 6.427,2.063 0.51,0.24 10 false IB1 3.698,0.719 4.208,0.958 0.51,0.24 10 false (V) 6.26,0.729 6.771,0.969 0.51,0.24 10 false (V) 1.219,0.438 1.958,0.896 0.74,0.458 10 false Discharging 1.219,0.615 1.958,1.073 0.74,0.458 10 false Current 3.906,0.104 6.396,0.542 2.49,0.438 10 false Battery Current Sensor Output Voltage 3.271,0.323 4.01,0.781 0.74,0.458 10 false Output 3.281,0.5 4.021,0.958 0.74,0.458 10 false Voltage 3.271,0.688 4.01,1.146 0.74,0.458 10 false (IB1) 6.531,0.344 7.052,0.792 0.521,0.448 10 false Output 6.542,0.531 7.094,0.938 0.552,0.406 10 false Voltage 6.542,0.719 6.99,1.177 0.448,0.458 10 false (IB0) 3.198,3.344 4.063,3.688 0.865,0.344 10 false Current 6.333,3.229 7.146,3.667 0.813,0.438 10 false Discharging 6.313,3.396 6.958,3.75 0.646,0.354 10 false Current

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground The battery current sensor output voltage (IB0) is excessively low.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A
P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open The battery current sensor output voltage (IB0) is excessively high.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A
P0B0E11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground The battery current sensor output voltage (IB1) is excessively low.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A
P0B0E15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open The battery current sensor output voltage (IB1) is excessively high.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A
P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery Power source voltage (VIB) of the battery current sensor is excessively high.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A
P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open Power source voltage (VIB) of the battery current sensor is excessively low.
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV Battery A

Related Data List
DTC No. Data List
P0ABF11 Hybrid/EV Battery Current for Hybrid/EV Battery Control
Hybrid/EV Battery Current for Hybrid/EV Battery Control (Sub)
Hybrid/EV Battery Current Sensor Power Supply Voltage
P0ABF15
P0B0E11
P0B0E15
P1CBB12
P1CBB14

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 10 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

C375136E04
4.781,3.438 5.094,3.656 0.313,0.219 10 false z26 0.375,2.552 0.698,2.74 0.323,0.188 10 false z23 0.656,2.552 3.313,3.188 2.656,0.635 10 false No. 1 EV Battery Junction Block Assembly (Battery Current Sensor) 1.771,0.396 2.229,0.594 0.458,0.198 10 false VIB 5.125,0.396 5.583,0.594 0.458,0.198 10 false VIB 1.792,0.917 2.25,1.115 0.458,0.198 10 false IB0 5.146,0.917 5.604,1.115 0.458,0.198 10 false IB0 1.802,1.438 2.26,1.635 0.458,0.198 10 false IB1 5.146,1.438 5.604,1.635 0.458,0.198 10 false IB1 1.771,1.958 2.229,2.156 0.458,0.198 10 false GIB 5.146,1.969 5.604,2.167 0.458,0.198 10 false GIB 4.865,1.958 5.177,2.156 0.313,0.198 10 false 37 4.854,1.438 5.167,1.635 0.313,0.198 10 false 38 4.854,0.917 5.167,1.115 0.313,0.198 10 false 18 4.865,0.396 5.177,0.594 0.313,0.198 10 false 19 2.146,0.396 2.458,0.594 0.313,0.198 10 false 1 2.146,0.917 2.458,1.115 0.313,0.198 10 false 4 2.146,1.438 2.458,1.635 0.313,0.198 10 false 2 2.146,1.958 2.458,2.156 0.313,0.198 10 false 3 5.146,2.604 5.604,2.802 0.458,0.198 10 false GND 5.156,3.135 5.615,3.333 0.458,0.198 10 false GND1 4.865,2.479 5.177,2.677 0.313,0.198 10 false 11 4.854,3 5.167,3.198 0.313,0.198 10 false 31 5.073,3.427 6.51,3.646 1.438,0.219 10 false Battery ECU Assembly

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK DTC OUTPUT (EV BATTERY, EV)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > EV Battery > Trouble Codes
50001 398
Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
Only P0ABF11, P0ABF15, P0B0E11, P0B0E15, P1CBB12 or P1CBB14 for Hybrid battery system is output A
P0ABF11, P0ABF15, P0B0E11, P0B0E15, P1CBB12 or P1CBB14 is output and DTCs other than the DTCs in the table below are output B
P0ABF11, P0ABF15, P0B0E11, P0B0E15, P1CBB12 or P1CBB14 is output and Hybrid battery system DTCs in the table below are output C
P0ABF11, P0ABF15, P0B0E11, P0B0E15, P1CBB12 or P1CBB14 is output and Hybrid control system DTCs in the table below are output D


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation


Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK FREEZE FRAME DATA

B

2.CHECK FREEZE FRAME DATA

C

GO TO DTC CHART (HYBRID BATTERY SYSTEM)

D

2.CHECK FREEZE FRAME DATA

Pre-procedure1

a.

None.


Procedure1

a.

Check and record the "Hybrid/EV Battery Current Sensor Power Supply Voltage" freeze frame data.

Powertrain > EV Battery > Trouble Codes
50001 398
HINT:

Use this for reference when measuring the EV battery current sensor power supply voltage.



Result:
Proceed to
NEXT


Post-procedure1

a.

Turn the ignition switch off.



NEXT

3.CHECK BATTERY ECU ASSEMBLY (IGCT VOLTAGE)
3.CHECK BATTERY ECU ASSEMBLY (IGCT VOLTAGE)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the center No. 2 floor to brace extension.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL



c.
C382281N05
2.688,0.25 3.146,0.479 0.458,0.229 2.74,0.281 3.115,0.448 0.375,0.167 10 true G156

Disconnect the G156 No. 2 EV battery pack wire connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the ignition switch to ON.


Procedure1

a.
C373320C12
1.49,0.24 1.969,0.458 0.479,0.219 1.792,1.531 2.896,1.01 true 0.51,0.927 1,1.25 true 3.01,0.854 3.375,1.031 0.365,0.177 10 false IGCT 1.552,0.292 1.948,0.469 0.396,0.177 10 false G156 0.115,0.125 0.427,0.281 0.313,0.156 10 false *a 0.177,0.792 0.635,0.99 0.458,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G156)Location & Routing

Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assembly

G156-14 (IGCT) - G156-1 (GND) Ignition switch ON 11 to 14 V


NOTICE:
·

Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

·

If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.




Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Disconnect the cable from the negative (-) auxiliary battery terminal.


c.

Reconnect the G156 No. 2 EV battery pack wire connector.


d.

Install the center No. 2 floor to brace extension.



OK

4.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY ECU ASSEMBLY POWER SOURCE CIRCUIT)

4.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper No. 1 EV battery cover sub-assembly.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373307N11
2.146,0.125 2.573,0.417 0.427,0.292 2.24,0.177 2.531,0.354 0.292,0.177 10 true z26

Disconnect the z26 battery ECU assembly connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



Procedure1

a.
C374185C47
1.49,1.604 1.896,1.896 0.406,0.292 1.49,0.052 1.948,0.354 0.458,0.302 1.656,2.604 2.75,1.823 true 2.313,1.073 2.76,1.323 true 0.438,3.031 0.604,2.677 true 2.323,0.844 2.74,0.427 true 0.625,1.979 1.635,2.427 true 0.552,0.75 1.729,1.031 true 1.563,0.146 2.021,0.344 0.458,0.198 10 false G156 1.594,1.698 2.052,1.896 0.458,0.198 10 false z26 0.146,0.104 0.458,0.26 0.313,0.156 10 false *a 0.208,1.573 0.521,1.729 0.313,0.156 10 false *b 0.25,3.083 0.865,3.281 0.615,0.198 10 false IGCT 0.188,0.677 0.802,0.875 0.615,0.198 10 false IGCT 0.292,1.875 0.75,2.073 0.458,0.198 10 false GND 2.833,0.313 3.292,0.51 0.458,0.198 10 false GND 2.844,1.74 3.302,1.938 0.458,0.198 10 false GND1 2.875,1.302 3.333,1.5 0.458,0.198 10 false GND1
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)
*b Rear view of wire harness connector
(to Battery ECU Assembly)


Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z26,G156)Location & Routing

Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assembly

Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assembly

z26-40 (IGCT) - G156-14 (IGCT) Always Below 1 Ω
z26-11 (GND) - G156-1 (GND) Always Below 1 Ω
z26-31 (GND1) - G156-10 (GND1) Always Below 1 Ω



b.

Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z26,G156)Location & Routing

Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assembly

Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assembly

z26-40 (IGCT) or G156-14 (IGCT) - Body ground and other terminals Always 10 kΩ or higher
z26-11 (GND) or G156-1 (GND) - Body ground and other terminals Always 10 kΩ or higher
z26-31 (GND1) or G156-10 (GND1) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the z26 battery ECU assembly connector.


b.

Install the upper No. 1 EV battery cover sub-assembly.



OK

5.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)

5.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY)

OK

6.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY ECU ASSEMBLY - NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY)

6.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
C374918C22
1.448,2.323 1.896,2.594 0.448,0.271 1.875,3.927 2.427,4.167 true 1.833,3.5 2.396,3.219 true 0.156,0.208 0.396,0.365 0.24,0.156 10 true *a 1.563,2.375 1.875,2.573 0.313,0.198 10 false z23 2.531,4.115 2.99,4.313 0.458,0.198 10 false GIB 2.531,3.135 2.99,3.333 0.458,0.198 10 false VIB
*a Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-1 (VIB) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
4.6 to 5.4 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Install the upper EV battery cover panel.



OK

7.CHECK BATTERY ECU ASSEMBLY (GIB - GND)

NG

15.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)
7.CHECK BATTERY ECU ASSEMBLY (GIB - GND)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Remove the upper No. 1 EV battery cover sub-assembly.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



b.
C373307N11
2.146,0.125 2.573,0.417 0.427,0.292 2.24,0.177 2.531,0.354 0.292,0.177 10 true z26

Disconnect the z26 battery ECU assembly connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



Procedure1

a.
C374184C12
1.427,1.656 1.865,1.958 0.438,0.302 1.25,3.177 0.875,2.813 true 2.01,3.156 1.635,2.813 true 1.969,2.083 1.646,2.615 true 2.052,1.99 2.51,2.188 0.458,0.198 10 false GND 1.313,3.125 1.771,3.323 0.458,0.198 10 false GIB 2.094,3.094 2.552,3.292 0.458,0.198 10 false GND1 1.542,1.74 1.854,1.938 0.313,0.198 10 false z26 0.177,0.229 0.49,0.385 0.313,0.156 10 false *a
*a Component without harness connected
(Battery ECU Assembly)


Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z26)Location & Routing

Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assembly

z26-37 (GIB) - z26-11 (GND) Always Below 1 Ω
z26-37 (GIB) - z26-31 (GND1) Always Below 1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the z26 battery ECU assembly connector.


b.

Install the upper No.1 EV battery cover sub-assembly.



OK

8.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))

NG

8.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
C374918C23
1.438,2.313 1.927,2.615 0.49,0.302 1.865,3.938 2.635,4.25 true 0.688,3.135 1.51,3.479 true 1.573,2.396 1.885,2.594 0.313,0.198 10 false z23 0.385,3.021 0.844,3.219 0.458,0.198 10 false IB1 2.781,4.188 3.24,4.385 0.458,0.198 10 false GIB 0.167,0.146 0.427,0.333 0.26,0.188 10 true *a
*a Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-2 (IB1) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
2.1 to 2.3 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector wire from the auxiliary battery.


b.

Install the upper EV battery cover panel.



OK

9.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))

NG

13.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))
9.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
C374918C24
1.438,2.313 1.927,2.615 0.49,0.302 1.865,3.938 2.635,4.25 true 0.635,4.208 1.49,3.927 true 1.573,2.385 1.885,2.583 0.313,0.198 10 false z23 0.323,4.135 0.781,4.333 0.458,0.198 10 false IB0 2.781,4.188 3.24,4.385 0.458,0.198 10 false GIB 0.167,0.146 0.427,0.333 0.26,0.188 10 true *a
*a Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-4 (IB0) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
2.7 to 2.9 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Install the upper EV battery cover panel.



OK

NG

10.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))
10.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
C374918C24
1.438,2.313 1.927,2.615 0.49,0.302 1.865,3.938 2.635,4.25 true 0.635,4.208 1.49,3.927 true 1.573,2.385 1.885,2.583 0.313,0.198 10 false z23 0.323,4.135 0.781,4.333 0.458,0.198 10 false IB0 2.781,4.188 3.24,4.385 0.458,0.198 10 false GIB 0.167,0.146 0.427,0.333 0.26,0.188 10 true *a
*a Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-4 (IB0) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)



Result:
Result Proceed to
0.4 to 4.6 V A
Below 0.4 V B
4.6 V or higher C


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Install the upper EV battery cover panel.



A

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

B

11.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))

C

12.CHECK BATTERY ECU ASSEMBLY (VIB - IB0)
11.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB0))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C371962N08
1.563,0.469 1.99,0.729 0.427,0.26 1.635,0.5 1.927,0.688 0.292,0.188 10 true z23

Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
A479524C02
2.333,1.135 2.729,1.365 0.396,0.229 2.438,1.771 1.823,1.469 true 1,1.771 1.573,1.458 true 2.521,1.75 2.854,1.99 0.333,0.24 10 false IB0 0.729,1.719 1.094,1.969 0.365,0.25 10 false GIB 0.188,0.146 0.427,0.292 0.24,0.146 10 false *a 2.427,1.167 2.802,1.469 0.375,0.302 10 false z23
*a Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-4 (IB0) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
4.6 to 5.4 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.


c.

Install the upper EV battery cover panel.



OK

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

NG

12.CHECK BATTERY ECU ASSEMBLY (VIB - IB0)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C371962N08
1.563,0.469 1.99,0.729 0.427,0.26 1.635,0.5 1.927,0.688 0.292,0.188 10 true z23

Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



Procedure1

a.
A479524C03
2.333,1.135 2.729,1.365 0.396,0.229 1.573,1.146 0.99,0.906 true 2.417,1.74 1.833,1.5 true 0.729,0.823 1.063,1.063 0.333,0.24 10 false VIB 2.5,1.688 2.865,1.938 0.365,0.25 10 false IB0 0.188,0.146 0.427,0.292 0.24,0.146 10 false *a 2.427,1.167 2.802,1.469 0.375,0.302 10 false z23
*a Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-1 (VIB) - z23-4 (IB0) Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.


b.

Install the upper EV battery cover panel.



OK

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

NG

13.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
C374918C23
1.438,2.313 1.927,2.615 0.49,0.302 1.865,3.938 2.635,4.25 true 0.688,3.135 1.51,3.479 true 1.573,2.396 1.885,2.594 0.313,0.198 10 false z23 0.385,3.021 0.844,3.219 0.458,0.198 10 false IB1 2.781,4.188 3.24,4.385 0.458,0.198 10 false GIB 0.167,0.146 0.427,0.333 0.26,0.188 10 true *a
*a Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-2 (IB1) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)



Result:
Result Proceed to
0.4 to 4.6 V A
Below 0.4 V B
4.6 V or higher C


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Install the upper EV battery cover panel.



A

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

B

14.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))

C

16.CHECK BATTERY ECU ASSEMBLY (VIB - IB1)
14.CHECK BATTERY ECU ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE (IB1))
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C371962N08
1.563,0.469 1.99,0.729 0.427,0.26 1.635,0.5 1.927,0.688 0.292,0.188 10 true z23

Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
A479524C04
2.333,1.135 2.729,1.365 0.396,0.229 2.354,0.646 1.833,1.115 true 1,1.771 1.573,1.458 true 2.417,0.542 2.75,0.781 0.333,0.24 10 false IB1 0.729,1.719 1.094,1.969 0.365,0.25 10 false GIB 0.188,0.146 0.427,0.292 0.24,0.146 10 false *a 2.427,1.167 2.802,1.469 0.375,0.302 10 false z23
*a Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-2 (IB1) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
4.6 to 5.4 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.


c.

Install the upper EV battery cover panel.



OK

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

NG

15.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C371962N08
1.563,0.469 1.99,0.729 0.427,0.26 1.635,0.5 1.927,0.688 0.292,0.188 10 true z23

Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
C373319C08
1.521,2.688 1.979,2.958 0.458,0.271 0.573,3.042 1.74,3.823 true 2.5,3.594 2.927,2.99 true 0.125,0.156 0.354,0.333 0.229,0.177 10 true *a 1.583,2.74 2.042,2.938 0.458,0.198 10 false G156 0.25,2.875 0.615,3.052 0.365,0.177 10 false IGCT 2.958,2.823 3.354,3.021 0.396,0.198 10 false GND
*a Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector)


Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).

NOTICE:

Make sure that the battery positive and battery negative do not contact one another.



Procedure1

a.
A479524C01
2.333,1.135 2.729,1.365 0.396,0.229 1.573,1.146 0.99,0.906 true 1,1.771 1.573,1.458 true 0.729,0.823 1.063,1.063 0.333,0.24 10 false VIB 0.729,1.719 1.094,1.969 0.365,0.25 10 false GIB 0.188,0.146 0.427,0.292 0.24,0.146 10 false *a 2.427,1.167 2.802,1.469 0.375,0.302 10 false z23
*a Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-1 (VIB) - z23-3 (GIB) Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND)
4.6 to 5.4 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.


b.

Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.


c.

Install the upper EV battery cover panel.



OK

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

NG

16.CHECK BATTERY ECU ASSEMBLY (VIB - IB1)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL



c.
C371962N08
1.563,0.469 1.99,0.729 0.427,0.26 1.635,0.5 1.927,0.688 0.292,0.188 10 true z23

Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



Procedure1

a.
A479524C06
2.333,1.135 2.729,1.365 0.396,0.229 1.573,1.146 0.99,0.906 true 1.813,1.115 2.385,0.885 true 0.729,0.823 1.063,1.063 0.333,0.24 10 false VIB 2.469,0.771 2.833,1.021 0.365,0.25 10 false IB1 0.188,0.146 0.427,0.292 0.24,0.146 10 false *a 2.427,1.167 2.802,1.469 0.375,0.302 10 false z23
*a Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor))


Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z23)Location & Routing

Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z23-1 (VIB) - z23-2 (IB1) Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.


b.

Install the upper EV battery cover panel.



OK

REPLACE NO. 1 EV BATTERY JUNCTION BLOCK ASSEMBLY

NG