The hydrogen system of the FC system feeds the FC stack with hydrogen, so that the FC stack can generate power. The hydrogen supply line, which is a part of the hydrogen system, covers the tank shut valves up to the hydrogen injectors, and its internal pressure is maintained at higher than the pressure applied to the FC stack. The hydrogen supply line consists of the high-range pressure area where the pressure equal to the tank internal pressure is applied, and the medium-range pressure area.
Pressures in the hydrogen supply line located between the tank shut valves up to the hydrogen injectors are monitored by the system, and if a pressure decrease is found in the supply line despite the tank shut valves and hydrogen injectors being closed, this will be interpreted as external leaks, and the DTC will be stored.
For the circuit diagram, refer to DTC P1E427A.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1E427A
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1E437A | Hydrogen Leak (High/Medium Pressure Area) Fluid Leak or Seal Failure | During the FC Startup Process or FC Shutdown Process, the hydrogen supply pipe (high-pressure and medium-pressure pipes) flow path is sealed off by closing the tank shut valve and injector. The subsequent pressure is then monitored, and if the absolute quantity of the leak based on that pressure is the specified value or more, a hydrogen leak is detected.
(1 trip detection logic) |
·
High-range hydrogen pressure pipe ·
Medium-range hydrogen pressure pipe ·
Low-range hydrogen pressure pipe ·
Hydrogen tank pressure sensor (for outlet side) ·
Hydrogen primary pressure sensor ·
Exhaust drainage valve (hydrogen recirculation separator assembly) ·
FC stack assembly ·
Sealed area of each component |
Master Warning: Comes on | EV | B |
Troubleshoot hydrogen leaks from the high-range pressure area first.
If there is a leak in the medium-range pressure area, only the "High-Range Hydrogen Pressure (Filtered Value)" decreases, and when it reaches the "Medium-Range Hydrogen Pressure (Filtered Value)", the "Medium-Range Hydrogen Pressure (Filtered Value)" will begin decreasing.
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | ○ | - | - | - | ○ |
| DTC No. | Data List |
|---|---|
| P1E437A | ·
Tank Shut Valve 1 Drive Status ·
Tank Shut Valve 2 Drive Status ·
Tank Shut Valve 3 Drive Status ·
Hydrogen Injector 1 Injection Period ·
Hydrogen Injector 2 Injection Period ·
Hydrogen Injector 3 Injection Period ·
Target Low-Range Hydrogen Pressure ·
High-Range Hydrogen Pressure (Filtered Value) ·
Medium-Range Hydrogen Pressure (Filtered Value) ·
Low-Range Hydrogen Pressure (Filtered Value) ·
Motor Room Hydrogen Density ·
Tank Area 1 Hydrogen Density ·
Tank Area 2 Hydrogen Density ·
Exhaust Drainage Valve ·
Atmospheric Pressure (Filtered Value) ·
FC Work Mode |
By performing the instructions below, leaks from the high- or medium-range hydrogen pressure system can be identified to some extent by the changes in the "High-Range Hydrogen Pressure (Filtered Value)" and "Medium-Range Hydrogen Pressure (Filtered Value)" with the ignition switch ON.
Turn the ignition switch to ON (READY) with the shift state in park (P).
Turn the ignition switch off.
Turn the ignition switch to ON and observe changes in the "High-Range Hydrogen Pressure (Filtered Value)" and "Medium-Range Hydrogen Pressure (Filtered Value)" in the Data List.
When the ignition switch is ON, as the tank shut valves and hydrogen injectors are closed, the high- and medium-range hydrogen pressures do not show significant variations in their values, and they are stable.
If hydrogen leakage is suspected, the FC system forces all tank shut valves and hydrogen injectors to close and a decrease in the pressure will be checked during the FC Startup Process.
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Click hereEngine / Hybrid System>FUEL>FUEL SYSTEM>PRECAUTION
After completion of repair, check that no hydrogen leaks from the hydrogen pipes using a hydrogen gas detector.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Mode" is FC Working. Then, wait for 2 minutes or more (If FC system cannot be activated, check the DTCs that are present at the time).
Turn the ignition switch off and wait for 10 minutes or more.
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Result | Proceed to |
|---|---|
| Only P1E437A is output | A |
| P1E437A is output and DTCs other than the DTCs in the table below are output | B |
| P1E437A is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1DB011 (FC) | High-Range Hydrogen Pressure Sensor Circuit Short to Ground |
| P1DB015 (FC) | High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | |
| P1DB511 (FC) | Medium-Range Hydrogen Pressure Sensor Circuit Short to Ground | |
| P1DB515 (FC) | Medium-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | |
| P1D9A1C (FC) | Hydrogen Injector 1 Circuit Voltage Out of Range | |
| P1DA01C (FC) | Hydrogen Injector 2 Circuit Voltage Out of Range | |
| P1DA51C (FC) | Hydrogen Injector 3 Circuit Voltage Out of Range | |
| P1DAA12 (FC) | Exhaust Drainage Valve Circuit Short to Battery | |
| P1DAA14 (FC) | Exhaust Drainage Valve Circuit Short to Ground or Open | |
DTC P1E437A may be store due to problems that cause the DTCs shown above to output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.
Post-procedure1
Turn the ignition switch off.
A
B
C
Check for FC coolant leaks and the FC stack coolant level in the FC radiator reserve tank.
Pre-procedure1
Turn the ignition switch ON.
Procedure1
Turn the ignition switch to ON (READY) while checking the "FC Work Mode".
| Tester Display |
|---|
| FC Work Mode |
| Result | Proceed to |
|---|---|
| "FC Work Mode" switches to "Working" | A |
| "FC Work Mode" is "Stop" without switching to "Working" | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Read the freeze frame data of DTC P1E437A.
| Tester Display |
|---|
| Atmospheric Pressure (Filtered Value) |
| Low-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The "Atmospheric Pressure (Filtered Value)" is within the "Low-Range Hydrogen Pressure (Filtered Value)" plus 8.7 kPa | A |
| Other than above. | B |
Post-procedure1
Turn the ignition switch off.
A
B
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Pre-procedure1
Ensure the safety of the areas in front and at the back of the vehicle.
Put wheel chocks and securely apply the parking brake.
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working, "FC Intermittent Operation" is OFF, and "Exhaust Drainage Valve" is Close.
| Active Test Display |
|---|
| Activate the Exhaust Drainage Valve |
| Data List Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
| Exhaust Drainage Valve |
| *1 | Tailpipe |
| *2 | Hydrogen Gas Detector Probe |
Use the hydrogen gas detector to measure and record the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is closed.
Perform this measurement in an environment where there is no wind.
Position the hydrogen gas detector probe in an area 100 mm (3.94 in.) away from the tailpipe opening. (Avoid locations underneath the tailpipe opening)
Position the hydrogen gas detector probe so that it is free from dropping water that comes from the tailpipe opening.
Perform the "Activate the Exhaust Drainage Valve" Active Test several times over 1 minute, and then, starting from the third test, use the hydrogen gas detector to measure the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is open.
The exhaust drainage valve will open for 1 second each time the Active Test is performed, so measure the hydrogen concentration for several seconds.
Hydrogen concentration may not increase while coolant escapes when the valve is first opened. Therefore, start measuring from the third test.
There is a delayed response when performing detection using the hydrogen gas detector, so measure for several seconds.
"FC Intermittent Operation" in the Data List will be more likely to turn OFF if the accelerator pedal is depressed with the shift state in park (P).
| Result | Proceed to |
|---|---|
| The hydrogen concentration of the hydrogen gas detector will increase when "Exhaust Drainage Valve" in the Data List is Open rather than when "Exhaust Drainage Valve" is Close. | A |
| Other than above* | B |
*: The exhaust drainage valve is malfunctioning
Exhaust drainage valve is stuck closed:
Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained low.
Exhaust drainage valve is stuck open:
Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained high when the ignition switch is on (READY).
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Open the hood with the ignition switch off, check for hydrogen leaks around the underbody and in the front compartment with a hydrogen gas detector. If leakage is found, pay extra attention to fire safety in the following operations.
For procedures to check for leaks from hydrogen pipes and components (high-range pressure and medium-range pressure), refer toEngine / Hybrid System>FUEL>FUEL SYSTEM>ON-VEHICLE INSPECTION.
Pre-procedure1
Turn the ignition switch off.
Remove the under cover.
Procedure1
Check that the hydrogen tank and hydrogen pipes are not damaged.
Check for a gas leaking sound, and then check if there are hydrogen leaks in the hydrogen pipes and components with a hydrogen gas detector.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | High-range Hydrogen Pressure Pipe (for filling) |
| *3 | Hydrogen Tank Tube Joint | *4 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *5 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *6 | No. 1 Hydrogen Tank Assembly |
| *7 | No. 2 Hydrogen Tank Assembly | *8 | No. 3 Hydrogen Tank Assembly |
| *9 | High-range Hydrogen Pressure Pipe (for feeding) | *10 | Hydrogen Supply Regulator Assembly |
| *11 | Medium-range Hydrogen Pressure Pipe | *12 | Low-range Hydrogen Pressure Pipe |
| *13 | FC Stack Assembly | *14 | Hydrogen Injector |
| *a | High-range Pressure Area (when filling)
(Hydrogen Inlet Receptacle Assembly → Hydrogen Tank Assembly ) |
*b | High-range Pressure Area
(Hydrogen Tank Assembly → Hydrogen Supply Regulator Assembly) |
| *c | Medium-range Pressure Area
(Hydrogen Supply Regulator Assembly → Hydrogen Injector) |
*d | Low-range Pressure Area
(Hydrogen Injector → FC Stack) |
300 ppm or less. (Hydrogen gas detector)
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the under cover.
OK
NG
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Open the hood with the ignition switch off, check for hydrogen leaks around the underbody and in the front compartment with a hydrogen gas detector. If leakage is found, pay extra attention to fire safety in the following operations.
Turn the ignition switch to ON (READY) causes the tank shut valve to open, and this pressurizes hydrogen in the hydrogen pipes. At this time, locate leaking areas of the hydrogen pipe. If there are leaks, the hydrogen pressure in the pipe decreases gradually, so perform checks quickly.
For procedures to check for leaks from hydrogen pipes and components (high-range pressure and medium-range pressure), refer toEngine / Hybrid System>FUEL>FUEL SYSTEM>ON-VEHICLE INSPECTION.
Pre-procedure1
Remove the under cover.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
If there are no leaks, the high-range and medium-range hydrogen systems will be pressurized full in virtually a few seconds after the ignition switch is turned to ON (READY) (the tank shut valves open). For the low-range hydrogen system, after the ignition switch is turned to ON (READY), when the "FC Work Mode" in the Data List enters Working and Intermittent Operation turns OFF, the hydrogen injector is caused to open so that hydrogen can be supplied.
Turn the ignition switch off.
Procedure1
Check for a gas leaking sound, and then check if there are hydrogen leaks in the hydrogen pipes and components with a hydrogen gas detector.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | High-range Hydrogen Pressure Pipe (for filling) |
| *3 | Hydrogen Tank Tube Joint | *4 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *5 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *6 | No. 1 Hydrogen Tank Assembly |
| *7 | No. 2 Hydrogen Tank Assembly | *8 | No. 3 Hydrogen Tank Assembly |
| *9 | High-range Hydrogen Pressure Pipe (for feeding) | *10 | Hydrogen Supply Regulator Assembly |
| *11 | Medium-range Hydrogen Pressure Pipe | *12 | Low-range Hydrogen Pressure Pipe |
| *13 | FC Stack Assembly | *14 | Hydrogen Injector |
| *a | High-range Pressure Area (when filling)
(Hydrogen Inlet Receptacle Assembly → Hydrogen Tank Assembly ) |
*b | High-range Pressure Area
(Hydrogen Tank Assembly → Hydrogen Supply Regulator Assembly) |
| *c | Medium-range Pressure Area
(Hydrogen Supply Regulator Assembly → Hydrogen Injector) |
*d | Low-range Pressure Area
(Hydrogen Injector → FC Stack) |
300 ppm or less. (Hydrogen gas detector)
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the under cover.
OK
NG
Pre-procedure1
None
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF. Then, wait for 1 minute or more.
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1E437A is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Pre-procedure1
Turn the ignition switch to ON.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
If there are no leaks, the high-range and medium-range hydrogen systems will be pressurized full in virtually a few seconds after the ignition switch is turned to ON (READY) (the tank shut valves open). For the low-range hydrogen system, after the ignition switch is turned to ON (READY), when the "FC Work Mode" in the Data List enters Working and Intermittent Operation turns OFF, the hydrogen injector is caused to open so that hydrogen can be supplied.
Turn the ignition switch off.
Procedure1
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
Post-procedure1
None
NEXT
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
NEXT
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Perform Leak Check (Low Pressure Point Leak Check) in the Utility menu.
| Tester Display |
|---|
| Leak Check |
While performing the Low Pressure Point Leak Check, check the "Low-Range Hydrogen Pressure (Filtered Value)" and "Target Low-Range Hydrogen Pressure" displayed on the GTS.
While performing the Low Pressure Point Leak Check, measure the hydrogen concentration around the FC stack and at the tailpipe with a hydrogen gas detector.
| Result | Proceed to |
|---|---|
| The hydrogen concentration around the FC stack is 300 ppm or more | A |
| The "Low-Range Hydrogen Pressure (Filtered Value)" displayed on the GTS is below the "Target Low-Range Hydrogen Pressure" | B |
| The hydrogen concentration at the tailpipe is 30000 ppm or more (If the measurement range of the hydrogen gas detector is insufficient, the hydrogen concentration reaches 90% of the upper limit of the measurement range within 5 seconds of starting a measurement) | C |
| The hydrogen concentration at the tailpipe is below 30000 ppm (If the measurement range of the hydrogen gas detector is insufficient, the hydrogen concentration does not reach 90% of the upper limit of the measurement range within 5 seconds of starting a measurement) | D |
A
B
C
D
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Perform Leak Check (Low Pressure Point Leak Check) in the Utility menu.
| Tester Display |
|---|
| Leak Check |
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
NEXT