MALFUNCTION DESCRIPTION
These DTCs indicate the resolver output signal is abnormal. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly |
| FC air compressor motor resolver | ·
Open or short circuit in the resolver for FC air compressor motor control ·
Internal FC air compressor motor malfunction (entry of foreign matter, etc.) |
| Wire harness system between the resolver and inverter with converter assembly | ·
Open or short circuit in the wire harness ·
The connectors are not connected properly |
| Inside of inverter | Inverter with converter assembly internal circuit malfunction |
Refer to the system description for the FC air compressor motor resolver circuit.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D7516 | FC Air Compressor Motor Position Sensor Circuit Voltage Below Threshold | Interphase short in the FC air compressor motor resolver circuit:
A short circuit between signal lines of FC air compressor motor resolver phases is electrically detected. (1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| P1D751C | FC Air Compressor Motor Position Sensor Circuit Voltage Out of Range | FC air compressor motor resolver signal is out of the normal range (amplitude is too large or too small).
(1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| P1D7522 | FC Air Compressor Motor Position Sensor Signal Amplitude > Maximum | Open or short in the FC air compressor motor resolver circuit:
FC air compressor motor resolver signal is out of the normal range (amplitude is extremely small). (1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Turn the ignition switch to ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC Intermittent Operation.
Push the P position switch (shift position indicator) to select park (P), turn the ignition switch to ON (READY) and wait until the FC system is started. Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY).
FC system is started: "Working" is displayed for the Data List item "FC Work Mode" and "FC Intermittent Operation" is OFF.
With the FC system operating, wait for 15 seconds or more.
Drive the vehicle in drive (D) for 5 m (16 ft.) or more.
Drive the vehicle in reverse (R) for 5 m (16 ft.) or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the FC air compressor motor resolver circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1D7516, P1D751C or P1D7522 is output, or DTCs other than P06B01C, P06E61C, P06D61C or P1C731C is output simultaneously | A |
| P06B01C, P06E61C, P06D61C or P1C731C is output simultaneously | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT