The EV battery intake air temperature sensor is mounted on the EV supply battery assembly. The resistance of the sensor varies in accordance with changes in the intake air temperature. The characteristics of the EV battery intake air temperature sensor are the same as those of the battery temperature sensors (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A9B11). The battery ECU assembly uses signals from the EV battery intake air temperature sensor to control the air volume of the battery cooling blower assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground | The EV battery intake air temperature sensor output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value.
(1 trip detection logic) |
·
No. 2 EV battery pack wire (EV battery intake air temperature sensor) ·
Battery ECU assembly ·
Wire harness or connector ·
No. 1 EV battery junction block assembly |
Master Warning:
Comes on |
EV Battery | A |
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open | The EV battery intake air temperature sensor output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value.
(1 trip detection logic) |
·
No. 2 EV battery pack wire (EV battery intake air temperature sensor) ·
Battery ECU assembly ·
Wire harness or connector ·
No. 1 EV battery junction block assembly |
Master Warning:
Comes on |
EV Battery | A |
After checking for the above DTCs, check the EV Battery Data List item "Hybrid/EV Battery Cooling Fan Intake Air Temperature 1" using the GTS.
| Displayed Temperature | Malfunction |
|---|---|
| -45°C (-49°F) or less | Open or +B short circuit |
| 95°C (203°F) or higher | GND short |
| DTC No. | Data List |
|---|---|
| P0AAC11 | Hybrid/EV Battery Cooling Fan Intake Air Temperature 1 |
| P0AAC15 |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds.
Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0AAC11 or P0AAC15 for Hybrid battery system is output | A |
| P0AAC11 or P0AAC15 is output and DTCs other than the DTCs in the table below are output | B |
| P0AAC11 or P0AAC15 is output and Hybrid battery system DTCs in the table below are output | C |
| P0AAC11 or P0AAC15 is output and Hybrid control system DTCs in the table below are output | D |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Pre-procedure1
None.
Procedure1
Check and record the "Hybrid/EV Battery Current Sensor Power Supply Voltage" freeze frame data.
Use this for reference when measuring the EV battery current sensor power supply voltage.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Procedure1
Check the connections of the z26 battery ECU assembly connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Procedure1
Visually check the installation condition of the EV battery intake air temperature sensor.
| Result | Proceed to |
|---|---|
| The EV battery intake air temperature sensor is installed in the correct location and its claws are engaged securely. | A |
| The claws of the EV battery intake air temperature sensor are damaged. | B |
| The EV battery intake air temperature sensor is not installed correctly, but its claws are not damaged. | C |
Post-procedure1
Install the upper EV battery cover panel.
A
B
C
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value (s) in the table below.
| Tester Connection | Condition | Thermistor Temperature | Specified Condition |
|---|---|---|---|
|
Click Location & Routing(z26)Location & Routingewd_type=routing;type=c;code=z26 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=28,8 |
|||
| z26-28 (TC0) - z26-8 (GC0) | Always | 0 to 10°C (32 to 50°F) | 17.7 to 27.8 kΩ |
| z26-28 (TC0) - z26-8 (GC0) | Always | 10 to 20°C (50 to 68°F) | 12.0 to 18.2 kΩ |
| z26-28 (TC0) - z26-8 (GC0) | Always | 20 to 30°C (68 to 86°F) | 8.22 to 12.2 kΩ |
| z26-28 (TC0) - z26-8 (GC0) | Always | 30 to 40°C (86 to 104°F) | 5.74 to 8.41 kΩ |
| z26-28 (TC0) - z26-8 (GC0) | Always | 40 to 50°C (104 to 122°F) | 4.09 to 5.91 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connectors.
Install the upper No.1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value (s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26)Location & Routingewd_type=routing;type=c;code=z26 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=28,8 |
||
| z26-28 (TC0) - Body ground and other terminals | Always | 10 kΩ or higher |
| z26-8 (GC0) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connectors.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
| *b | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26,z23)Location & Routingewd_type=routing;type=c,c;code=z26,z23 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=19,37 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=1,3 |
||
| z26-19 (VIB) - z23-1 (VIB) | Always | Below 1 Ω |
| z26-37 (GIB) - z23-3 (GIB) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26,z23)Location & Routingewd_type=routing;type=c,c;code=z26,z23 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=19,37 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=1,3 |
||
| z26-19 (VIB) or z23-1 (VIB) - Body ground and other terminals | Always | 10 kΩ or higher |
| z26-37 (GIB) or z23-3 (GIB) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.
Reconnect the z26 battery ECU assembly connector.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).
Make sure that the battery positive and battery negative do not contact one another.
Procedure1
| *a | Component with harness connected
(Battery ECU Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26)Location & Routingewd_type=routing;type=c;code=z26 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=19,37 |
||
| z26-19 (VIB) - z26-37 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND) |
4.6 to 5.4 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Disconnect the z23 battery current sensor connector from the No. 1 EV battery junction block assembly.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).
Make sure that the battery positive and battery negative do not contact one another.
Procedure1
| *a | Front view of wire harness connector
(to No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z23)Location & Routingewd_type=routing;type=c;code=z23 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=1,3 |
||
| z23-1 (VIB) - z23-3 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND) |
4.6 to 5.4 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.
Reconnect the z23 battery current sensor connector to the No. 1 EV battery junction block assembly.
Install the upper EV battery cover panel.
OK
NG