Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0453477 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P30004B  Hybrid/EV Battery Control System Over Temperature  


DESCRIPTION

The battery ECU assembly monitors the temperature of the EV supply battery assembly to detect if it becomes excessively high.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P30004B Hybrid/EV Battery Control System Over Temperature The battery ECU assembly detects an EV battery cooling system error signal.
(1 trip detection logic)
·

EV control ECU

·

No. 1 EV supply stack sub-assembly

·

No. 2 EV supply stack sub-assembly

·

EV battery terminal block


Master Warning:
Comes on
EV Battery A

Related Data List
DTC No. Data List
P30004B
·

Hybrid/EV Battery Temperature 1 to 6

·

Hybrid/EV Battery Cooling Fan Intake Air Temperature 1

·

Ambient Temperature

·

WOUT Control Limit Power

·

WIN Control Limit Power

·

Hybrid/EV Battery SOC

·

Hybrid/EV Battery Cooling Fan 1 Frequency



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 10 minutes or more.

3.

Drive the vehicle for approximately 10 minutes according to the freeze frame data items "Vehicle Speed", "Hybrid/EV Battery Temperature 1 to 6", "Hybrid/EV Battery Cooling Fan Intake Air Temperature 1", "Ambient Temperature" and "Hybrid/EV Battery Current".

4.

Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly

-

Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C06
0.604,4.135 0.917,4.333 0.313,0.198 10 false *a 2.719,4.135 3.031,4.333 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an EV supply battery assembly, make sure to return it through an authorized collection agent who is capable of handling it safely. If the EV supply battery assembly is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the EV supply battery assembly is disposed of improperly or abandoned. Therefore, make sure to return all EV supply battery assemblies through an authorized collection agent.


·

Before returning the EV supply battery assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION

·

Before returning the EV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the EV supply battery assembly and EV supply stack sub-assemblies.

·
A358020

After removing the EV supply battery assembly, keep it away from water. Exposure to water may cause the EV supply battery assembly to produce heat, resulting in a fire.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK DTC OUTPUT (EV BATTERY, EV)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > EV Battery > Trouble Codes
50001 398
Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
Only P30004B for Hybrid battery system is output A
P30004B and DTCs other than the DTCs in the table below are output B
P30004B and Hybrid battery system DTCs in the table below are output C
P30004B and Hybrid control system DTCs in the table below are output D


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P0A8111 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
P0A8115 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open
P0A8196 Hybrid/EV Battery Cooling Fan 1 Component Internal Failure
P0A9B11 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground
P0A9B15 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
P0A9B1C Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range
P0A9B2A Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range
P0AAC11 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground
P0AAC15 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
P0AC511 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground
P0AC515 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open
P0AC51C Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range
P0AC52A Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range
P0ACA11 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground
P0ACA15 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open
P0ACA1C Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range
P0ACA2A Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range
P0AE811 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground
P0AE815 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open
P0AE81C Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range
P0AE82A Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range
P0BC211 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground
P0BC215 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open
P0BC21C Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range
P0BC22A Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range
P0C3311 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground
P0C3315 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open
P0C331C Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range
P0C332A Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range
P306562 Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure
P306A62 Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation


Post-procedure1

a.

Turn the ignition switch off.



A

2.REPLACE EV CONTROL ECU

B

2.REPLACE EV CONTROL ECU

C

GO TO DTC CHART (HYBRID BATTERY SYSTEM)

D

2.REPLACE EV CONTROL ECU

NEXT

3.CHECK TOTAL DISTANCE DRIVEN
3.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.


Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when EV battery terminal block replaced = less than 200000 km (124280 mile)*1
Other than above B


HINT:

*1: If the EV battery terminal block has been replaced, use the total distance driven since it was replaced.



A

REPLACE NO. 1 EV SUPPLY STACK SUB-ASSEMBLY AND NO. 2 EV SUPPLY STACK SUB-ASSEMBLY

B

4.REPLACE NO. 1 EV SUPPLY STACK SUB-ASSEMBLY AND NO. 2 EV SUPPLY STACK SUB-ASSEMBLY
4.REPLACE NO. 1 EV SUPPLY STACK SUB-ASSEMBLY AND NO. 2 EV SUPPLY STACK SUB-ASSEMBLY

NEXT

REPLACE EV BATTERY TERMINAL BLOCK