The DC/DC converter converts the DC 144 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle's lighting, audio, and ECU systems. In addition, it charges the auxiliary battery. A transistor bridge circuit initially converts DC 144 V into alternating current, and a transformer lowers its voltage. Then, it is rectified and smoothed (into DC) and converted into DC 12 V. The DC/DC converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.
The power management control ECU uses the NODD signal line to transmit a stop command to the DC/DC converter and receive signals indicating the normal or abnormal condition of the 12 V charging system. If the vehicle is being driven with an inoperative DC/DC converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the power management control ECU monitors the operation of the DC/DC converter and alerts the driver if it detects a malfunction.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A08 | 264 | DC/DC converter malfunction or the auxiliary battery voltage drops to 11 V or less with the power switch on (READY).*1
(1 trip detection logic) |
·
Wire harness or connector ·
Inverter cooling system ·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Inverter with converter assembly ·
Fusible link (DC/DC) ·
Power management control ECU |
Refer to the wiring diagram for DTC P0AA6-526 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA6-526).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If there is a malfunction in the DC/DC converter internal circuit, P0A08-264 is stored within 2 minutes of the power switch being turned on (READY) regardless of the auxiliary battery voltage.
If the auxiliary battery voltage is low, the power switch will turn off regardless of DTCs being stored or not.
After repair, clear the DTCs, turn the power switch off and wait for 30 seconds or more and perform the following procedure to confirm that the auxiliary battery low voltage indicated by this DTC has been repaired.
Wait for 2 minutes with the shift lever in P, the power switch on (READY) and the following conditions met, then confirm that Data List item "+B" is between 13.0 and 15.0 V.
(If charging is not performed and the electrical load increases, +B voltage may not be steady and gradually drops.)
Headlight switch is in the HI position.
A/C blower fan switch is in the HI position.
Window defogger switch is turned on.
If the DC/DC converter has an internal malfunction, DTC P0A08-264 is stored regardless of the auxiliary battery voltage after performing this procedure.
If the auxiliary battery voltage drops, the power switch off regardless of DTCs being stored or not.
By performing the following procedure, the DC/DC converter function can be checked.
Connect the AC/DC 400 A probe to the positive auxiliary battery cable.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
Turn the power switch on (READY) and the headlight switch and A/C blower fan switch in the HI position, and the window defogger turned on.
Confirm that the current drawn from the auxiliary battery is 0 A or lower and the auxiliary battery voltage is between 13.0 and 15.0 V.
This DTC may be stored when a part other than the DC/DC converter is malfunctioning or depending on user operation.
| Malfunction Case | Remarks | Inspection Step |
|---|---|---|
| Fuse is blown. (DC/DC) | - | 4 |
| High-voltage insulation between the inverter, generator (MG1), motor (MG2) and body ground is poor (body ground). | DTC P0AA6 may be stored if the ground potential fluctuates due to a high-voltage insulation malfunction. | 1 |
| A signal connector of the power management control ECU or inverter is not connected securely. | - | 2. 3 |
| The DC/DC converter is malfunctioning. | Inspect the DC/DC converter function. | 9 |
| Control is suspended due to overheating. (The inverter water pump assembly is malfunctioning, the coolant is not sufficient, a hose is clogged, etc.) | When the inverter is overheating, the DC/DC converter has self protection control that suspends the DC/DC converter control. As that time, this DTC may be stored.
The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off. |
10 to 13, 17 |
If this vehicle is used to jump start another vehicle with a discharged battery, a fuse may blow due to overcurrent or the DC/DC converter self-protection may be activated.
In addition, if this vehicle is jump started by a vehicle with a 24 V auxiliary battery or the auxiliary battery cables are connected to the opposite auxiliary battery terminals, the same malfunction may occur and this DTC may be stored. (The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.)
If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the power switch is turned off, it may be impossible to turn it on (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.
If the power switch turns off immediately after it is turned on (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| Only P0A08-264 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A93-346 | Inverter Cooling System Performance |
| P0A94-547, 548, 549 | DC / DC Converter Performance |
| P0AA6-526, 613 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P3004-131, 803 | High Voltage Power Resource |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
OK
NG
OK
NG
Disconnect connector 1E from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1E-1 - 1D-1 (AMD) | Always | Below 1 Ω |
Check the fusible link (DC/DC) in the engine room relay block and junction block assembly for improper installation.
The fusible link is installed securely.
Connect the 1E connector to the engine room relay block and junction block assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| *1 | Motor Cable (for MG1) |
| *2 | Motor Cable (for MG2) |
Perform this inspection while the motor cable (for MG1) and motor cable (for MG2) are connected.
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Connect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1D-1 (AMD) - Body ground | Power switch off | Same as auxiliary battery voltage |
Disconnect the cable from the negative (-) auxiliary battery terminal.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the bolt for the AMD terminal is tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.
T=8.0 N*m {82 kgf*cm, 71in.*lbf }
| Result | Proceed to | |
|---|---|---|
| There are no arc marks. | The terminal is connected securely and there is no contact problem. | A |
| There are no arc marks. | The terminal is not connected securely and there is a contact problem. | B |
| There are arc marks. | - | C |
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-12 (NODD) - Body ground | Power switch off | 110 to 150 kΩ |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
OK
NG
The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.
Connect the AC/DC 400 A probe to the positive auxiliary battery line.
Install the service plug grip.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low.
Recharge the auxiliary battery and perform this procedure again.
Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
| Item | Condition | Specified Condition |
|---|---|---|
| Current flowing from auxiliary battery | Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
0 A or less
(no current from auxiliary battery) |
Measure the voltage according to the value(s) in the table below.
| Item | Condition | Specified Condition |
|---|---|---|
| Auxiliary battery voltage | Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
13 to 15 V |
Turn the power switch off.
OK
NG
A
B
C
OK
NG
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data Ambient Temperature using the intelligent tester.
Check if the freeze frame data Ambient Temperature is below freezing.
| Result | Proceed to |
|---|---|
| Ambient Temperature value is above freezing temperature of the HV coolant. | A |
| Ambient Temperature value is below freezing temperature of the HV coolant. | B |
HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.
A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.
If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1)
(Inverter with Converter Assembly Side) |
Connect the motor cable (for MG1).
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the motor cable (for MG2) from the inverter with converter assembly.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield Ground |
| *a | Motor Cable (for MG2)
(Inverter with Converter Assembly Side) |
Connect the motor cable (for MG2).
Install the inverter terminal cover.
OK
NG
Disconnect all the connectors from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-21 (NODD) - G57-6 (E1) | Power switch off | 110 to 150 kΩ |
| *a | Component without harness connected
(Power Management Control ECU) |
Connect the power management control ECU connectors.
OK
NG
NEXT
A
B
C
OK
NG
A
B
C
OK
NG