Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2011.12–2014.12
RM2170E _58 Vehicle Interior _057042 HEATING / AIR CONDITIONING _0278125 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1423/23  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored if refrigerant pressure on the high pressure side is extremely low (0.19 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.14 MPa (32.0 kgf/cm2, 455 psi) or more). The air conditioning pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.

DTC No. DTC Detection Condition Trouble Area
B1423/23
·

Open or short in air conditioning pressure sensor circuit

·

Refrigerant pressure on the high pressure side is extremely low (0.19 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.14 MPa (32.0 kgf/cm2, 455 psi) or more).


·

Air conditioning pressure sensor

·

Harness or connector between air conditioning pressure sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly

·

Cooler expansion valve (blocked, stuck)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooling fan system (condenser assembly cannot be cooled down)

·

A/C system (leaks, blocked)



WIRING DIAGRAM

E229252E79
2.229,1.969 2.323,2.146 0.094,0.177 10 false 1 2.229,1.021 2.323,1.198 0.094,0.177 10 false 2 4.854,1.021 4.948,1.198 0.094,0.177 10 false 9 4.771,1.969 4.948,2.146 0.177,0.177 10 false 13 1.885,1.115 2.229,1.417 0.344,0.302 10 false PR 0.885,3.927 3.052,4.333 2.167,0.406 10 false Air Conditioner Pressure Sensor 0.885,3.771 1.167,3.948 0.281,0.177 10 false A25 5.083,2.063 5.427,2.24 0.344,0.177 10 false SG-2 5.083,3.021 5.427,3.198 0.344,0.177 10 false S5-3 4.51,3.76 4.802,3.938 0.292,0.177 10 false G34 4.521,3.938 6.135,4.365 1.615,0.427 10 false Air Conditioning Amplifier Assembly 2.229,2.927 2.323,3.104 0.094,0.177 10 false 3 2,2.052 2.094,2.229 0.094,0.177 10 false - 2,3.021 2.104,3.198 0.104,0.177 10 false + 4.771,2.927 4.948,3.104 0.177,0.177 10 false 10 5.083,1.115 5.417,1.292 0.333,0.177 10 false PRE

CAUTION / NOTICE / HINT

HINT:

If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B1423 first.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.

Disconnect the A25 air conditioning pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A25-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V




OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-1 (-) - Body ground Always Below 1 Ω




OK

3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
3.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the A25 air conditioning pressure sensor connector.


b.
U183713E01
0.181,0.164 0.339,0.313 0.158,0.149 10 *a 0.701,1.655 1.007,1.804 0.306,0.149 10 PRE 1.254,0.212 1.557,0.368 0.303,0.156 10 G34 1.512,1.033 0.962,1.637 false

Remove the air conditioning amplifier assembly with connectors still connected.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G34-9 (PRE) - Body ground Power switch on (IG)
(A/C: off)
0.74 to 4.62 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)

HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioning pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.




OK

4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
4.INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Turn the power switch on (READY).


b.

Measure the voltage when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.62 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
U183713E01
0.181,0.164 0.339,0.313 0.158,0.149 10 *a 0.701,1.655 1.007,1.804 0.306,0.149 10 PRE 1.254,0.212 1.557,0.368 0.303,0.156 10 G34 1.512,1.033 0.962,1.637 false

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G34-9 (PRE) - Body ground Power switch on (IG)
(A/C: on)
0.74 to 4.62 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)

Result:
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C





A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C

13.INSPECT COOLING FAN SYSTEM
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
a.

Disconnect the G34 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-3 (+) - G34-10 (S5-3) Always Below 1 Ω
G34-10 (S5-3) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
a.

Disconnect the G34 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-1 (-) - G34-13 (SG-2) Always Below 1 Ω
G34-13 (SG-2) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
a.

Disconnect the G34 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-2 (PR) - G34-9 (PRE) Always Below 1 Ω
G34-9 (PRE) - Body ground Always 10 kΩ or higher




OK

8.INSPECT FOR A/C SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.INSPECT FOR A/C SYSTEM LEAK
a.

Install the manifold gauge set.


b.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.


c.

Evacuate the A/C system and check that vacuum can be maintained in it.

OK:

Vacuum can be maintained in the A/C system.


HINT:

If vacuum cannot be maintained in the A/C system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the A/C system.




OK

9.CHARGE SYSTEM WITH REFRIGERANT

NG

12.REPAIR A/C SYSTEM LEAK
9.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.




NEXT

10.RECHECK FOR DTC
10.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the A/C operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result:
Result Proceed to
DTC B1423/23 is output A
DTC B1423/23 is not output B


NOTICE:

If the DTC was set due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.




A

11.INSPECT AIR CONDITIONING PRESSURE SENSOR

B

END

11.INSPECT AIR CONDITIONING PRESSURE SENSOR
a.

Install the manifold gauge set.


b.

Reconnect the A25 air conditioning pressure sensor connector.


c.

Turn the power switch on (IG).


d.
U183714E01
0.181,0.164 0.339,0.313 0.158,0.149 10 *a 0.537,1.655 0.886,1.804 0.349,0.149 10 SG-2 1.254,0.212 1.557,0.368 0.303,0.156 10 G34 1.213,1.033 0.834,1.637 false 1.795,1.655 2.101,1.804 0.306,0.149 10 PRE 1.513,1.033 1.891,1.637 false

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G34-9 (PRE) - G34-13 (SG-2) Refrigerant pressure:
(less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
0.74 to 4.62 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

12.REPAIR A/C SYSTEM LEAK
a.

Identify the area where refrigerant leaks from (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).


b.

Repair the identified area of the A/C system.


c.

Evacuate the A/C system.



NEXT

13.INSPECT COOLING FAN SYSTEM
a.

Check that the cooling fan(s) operates normally.

HINT:

Refer to cooling fan system (See page Engine / Hybrid System>1NZ-FXE (COOLING)>COOLING FAN SYSTEM>ON-VEHICLE INSPECTION).




OK

14.CHARGE SYSTEM WITH REFRIGERANT

NG

REPAIR COOLING FAN SYSTEM

14.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.




NEXT

15.RECHECK FOR DTC
15.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.



Result:
Result Proceed to
DTC B1423/23 is output A
DTC B1423/23 is not output B




A

16.REPLACE COOLER EXPANSION VALVE

B

REPLACE COOLER CONDENSER ASSEMBLY

16.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a new one (See page Vehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL).

HINT:

Replace the cooler expansion valve with a new one because the cooler expansion valve is either stuck or clogged.




NEXT

17.CHARGE SYSTEM WITH REFRIGERANT
17.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.




NEXT

18.RECHECK FOR DTC
18.RECHECK FOR DTC
a.

Turn the power switch on (READY).


b.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a normal one, the condenser or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the condenser or pipes.



Result:
Result Proceed to
DTC B1423/23 is not output A
DTC B1423/23 is output B




A

END

B

CLEAN OR REPLACE CONDENSER OR PIPE