SFI SYSTEM > VC Output Circuit |


| 1.CHECK MIL |
Check that the Malfunction Indicator Lamp (MIL) illuminates when turning the power switch on (IG).
|
| ||||
| OK | ||
| ||
| 2.CHECK CONNECTION BETWEEN TECHSTREAM AND ECM |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Check the communication between the Techstream and ECM.
| Result | Proceed to |
| Communication is not possible | A |
| Communication is possible | B |
|
| ||||
| A | |
| 3.CHECK MIL (THROTTLE POSITION SENSOR) |
Disconnect the throttle position sensor connector.
Turn the power switch on (IG).
Check the MIL.
| Result | Proceed to |
| MIL does not illuminate | A |
| MIL illuminates | B |
|
| ||||
| A | |
| 4.CHECK MIL (CAMSHAFT POSITION SENSOR) |
Disconnect the camshaft position sensor connector.
Turn the power switch on (IG).
Check the MIL.
| Result | Proceed to |
| MIL does not illuminate | A |
| MIL illuminates | B |
|
| ||||
| A | |
| 5.CHECK MIL (MANIFOLD ABSOLUTE PRESSURE SENSOR) |
Disconnect the manifold absolute pressure sensor connector.
Turn the power switch on (IG).
Check the MIL.
| Result | Proceed to |
| MIL does not illuminate | A |
| MIL illuminates | B |
|
| ||||
| A | |
| 6.CHECK MIL (CANISTER PUMP MODULE) |
Disconnect the canister pump module connector.
Turn the power switch on (IG).
Check the MIL.
| Result | Proceed to |
| MIL does not illuminate | A |
| MIL illuminates | B |
|
| ||||
| A | |
| 7.CHECK HARNESS AND CONNECTOR (THROTTLE POSITION SENSOR - ECM) |
Disconnect the throttle position sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D28-88 (VCTA) or D4-5 (VC) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 8.CHECK HARNESS AND CONNECTOR (CAMSHAFT POSITION SENSOR - ECM) |
Disconnect the camshaft position sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D18-3 (VC) or D28-99 (VCV1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (MANIFOLD ABSOLUTE PRESSURE SENSOR - ECM) |
Disconnect the manifold absolute pressure sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D3-3 (VC) or D28-72 (VCPM) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 10.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Disconnect the canister pump module connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| S16-6 (VCC) or D28-113 (VCPP) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||