| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| 012 | Overheating | The surface sensor or control overheating sensor detects a temperature of 125°C (257°F) or higher. | ·
Heater assembly (surface sensor) ·
Heater assembly (control overheating sensor) ·
Engine coolant circuit (leaks, engine coolant quality, thermostat, water pump assembly) |
| 014 | Difference Evaluation Overheating | When the engine coolant temperature is 80°C (176°F) and the heater assembly is operating, the difference in temperatures detected by the surface sensor and control overheating sensor is 25°C (77°F) or higher. | ·
Heater assembly (surface sensor) ·
Heater assembly (control overheating sensor) ·
Engine coolant circuit (leaks, engine coolant quality, thermostat, water pump assembly) |
| 017 | Hardware Overheating | When neither DTC 012 nor 014 is detected, the control overheating sensor or surface sensor detects a temperature of 130°C (266°F). | ·
Heater assembly (surface sensor) ·
Heater assembly (control overheating sensor) ·
Engine coolant circuit (leaks, engine coolant quality, thermostat, water pump assembly) |
Check for engine coolant leaks.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the engine coolant quality.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the thermostat.
Inspect the thermostat.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the water pump assembly.
Inspect the water pump assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG